Description
AFViolet 450 Labeling Kit
The AFViolet 450 Labeling Kit provides the reagents needed to label antibodies and other proteins that carry primary amino groups. The kit uses an amine-reactive AFViolet 450 NHS ester that forms stable amide bonds with N-terminal and lysine side chains. Included 10 kDa filtration tubes allow buffer exchange and dye removal without dialysis. Researchers use the kit to generate violet-fluorescent protein conjugates for research applications.
AFViolet 450 is an amine-reactive fluorescent dye supplied as an N-hydroxysuccinimide (NHS) ester in a labeling kit for conjugating the dye to proteins. The dye is already activated and can be used directly, so no separate activation step is needed. Its target is the primary amino group (-NH2) found at protein N-termini and on lysine side chains. The kit is intended for labeling antibodies and other proteins that contain primary amino groups.
Labeled proteins are prepared when a fluorescent tag is needed on a specific protein of interest. The kit's listed applications are protein labeling and conjugation. Sources cited for this kit describe successful labeling of IgG, Annexin V, protein A/G, 2019-nCov spike protein, NGAL, and several recombinant protein fragments. Labeling performance varies between proteins because solubility, pH and temperature stability, purity, and the accessibility of lysine residues differ, so the manual recommends testing a small amount of an unfamiliar protein first. The kit is for research use only.
Labeling takes place within a defined pH range, in which the NHS ester reacts with primary amines to form a stable amide bond. The dye is dissolved in DMF, and the protein is buffer-exchanged into Labeling Buffer II. The reaction is incubated at 37 °C for 30 min in the dark, and an optional 1 M Tris (pH 8.7) step stops it. Excess dye is removed by ultrafiltration with 1× PBS on a 10 kDa filtration tube, which desalts the sample without dialysis. The dye has an excitation/absorption maximum of 405 nm and an emission maximum of 444 nm. The whole process takes about 90 min.
Suitable samples are purified proteins that contain primary amino groups. Free amines must be removed before labeling, including Tris, glycine, amino acids, imidazole, sodium azide, thiomersal, and ProClin. Carrier proteins such as BSA and gelatin also interfere and should be removed by affinity or chromatographic methods, or with the BSA Removal Kit. The initial protein concentration should be measured accurately, for example by BCA, before labeling. The dye is moisture-sensitive: store it at -20 °C or -80 °C with desiccant, equilibrate it to room temperature before opening, and do not mix it with water before use.
The manual provides a dye molar extinction coefficient of 35,000 L·mol⁻¹·cm⁻¹ and a CF280 correction factor of 0.238. The IgG extinction coefficient used in the calculations is 210,000 L·mol⁻¹·cm⁻¹. The recommended dye-to-protein molar ratio is 3.6:1 to 11:1 for proteins of 30 to 100 kDa, and it can be adjusted for molecular weight. The kit labels 0.1 to 1 mg of protein per run. The manual's worked example uses 1 mg of 50 kDa protein at about 2 mg/mL with a 6:1 molar ratio.
| Product name: | AFViolet 450 Labeling Kit |
| SKU: | AKES143 |
| Labeling chemistry: | Amine-reactive NHS ester |
| Target functional group: | Primary amino groups (N-terminal and lysine side chains) |
| Applications: | Protein labeling; antibody labeling (10 kDa filtration tube) |
| Excitation maximum: | 405 nm |
| Emission maximum: | 444 nm |
| Research use: | Research Use Only |
- Amine-reactive AFViolet 450 NHS ester, pre-activated and ready to dissolve in DMF
- Excitation maximum 405 nm; emission maximum 444 nm
- Filtration tubes desalt and exchange buffer without dialysis
- Total labeling workflow takes approximately 90 min
- Suitable for labeling 0.1 to 1 mg of protein per reaction



Within a defined pH range, the AFViolet 450 NHS ester specifically reacts with primary amino groups (N-terminal and lysine residue side chains) to form a stable amide bond, coupling the dye to the protein. The degree of labeling (DOS) is determined from absorbance at 280 nm and 405 nm using the dye extinction coefficient, the CF280 correction factor, and the protein extinction coefficient.
- Covalent fluorescent labeling of antibodies for research imaging and detection workflows
- Labeling of purified proteins that contain accessible primary amines
- Labeling of proteins such as IgG, Annexin V, protein A/G, and recombinant protein fragments, as reported in kit documentation
- Preparation of violet-excitable (405 nm) protein conjugates for research assays
| Component | Storage |
| AFViolet 450 NHS ester | -20°C, protect from light |
| Labeling Buffer II | 2-8°C |
| DMF | 2-8°C, protect from light |
| 1×PBS (pH 7.4) | 2-8°C |
| 1 M Tris (pH 8.7) | 2-8°C |
| 10 kDa filtration tube | Room temperature |
- Pipettor and tips (0.5 to 10 µL, 2 to 20 µL, 20 to 200 µL, 200 to 1000 µL)
- Ultraviolet spectrophotometer, nanodrop, or multifunctional microplate reader
- 37 °C incubator
- Centrifuge with centrifugal force up to 12,000 ×g
- Protein to be labeled, buffer exchanged into a amine-free buffer
Purified protein (antibodies and other proteins containing primary amino groups)
- Bring all kit reagents to room temperature for 20 min before use.
- Pre-wet the 10 kDa filter device: add 500 µL Labeling Buffer II to the dry filter device, stand at room temperature for 10 min, and discard the buffer before adding the protein. Keep the filter moist throughout the process.
- Concentrate and exchange buffer: place the filter device in a collection tube, add 1 mg of protein, and add Labeling Buffer II to a final volume of 0.5 mL. Cover and centrifuge at 12,000×g for 10 min, then discard the liquid in the collection tube.
- If the protein volume is greater than 0.5 mL, add it in several portions and concentrate by centrifugation between additions. The maximum filter device volume is 0.5 mL.
- If the protein contains free amino groups (Tris, amino acids, or other interferents), repeat ultrafiltration with Labeling Buffer II until they are fully removed.
- Recover the protein: invert the filter device into a new collection tube and centrifuge at 1,000×g for 2 min. Add an appropriate amount of Labeling Buffer II to the collected protein so that the concentration is about 2 mg/mL.
- Add 0.5 mL Labeling Buffer II to the filter device and place it on a pipette rack for later use.
- Do not load more than 1 mg of protein into the filter device.
Experiment preparation
- Bring all kit reagents to room temperature for 20 min before use. Reagents kept refrigerated after opening must be equilibrated the same way.
- Pre-wet the filter device: add 500 µL Labeling Buffer II to the dry filter device, stand at room temperature for 10 min, and discard the buffer. Keep the filter device moist throughout labeling.
- Dissolve 0.11 mg AFViolet 450 NHS ester in 10 µL DMF and stand for 10 min until fully dissolved. The resulting dye concentration is 13.06 mM. Cover and use promptly.
Labeling procedure (1 mg protein)
- Concentration and buffer exchange: place the filter device in a collection tube, add 1 mg protein and Labeling Buffer II to a final volume of 0.5 mL, cover, and centrifuge at 12,000 ×g for 10 min. Discard the collection tube liquid. Add protein in portions if the volume exceeds 0.5 mL. Repeat ultrafiltration with Labeling Buffer II if the protein contains free amines.
- Recovery and quantification: invert the filter device into a clean collection tube and centrifuge at 1000 ×g for 2 min. Adjust the protein to about 2 mg/mL with Labeling Buffer II. Add 0.5 mL Labeling Buffer II to the filter device and set it aside.
- Labeling reaction: immediately add 9.2 µL of 13.06 mM AFViolet 450 to the protein solution (dye:protein molar ratio of 6:1 for a 50 kDa protein). Mix gently and thoroughly, seal, and incubate at 37 °C for 30 min in the dark.
- (Optional) Blocking: add 10 µL of 1 M Tris (pH 8.7) per 100 µg protein, mix, and incubate at room temperature for 10 min.
- Ultrafiltration and purification: add 1×PBS to a final volume of 0.5 mL, mix gently, and transfer to the filter device that was set aside. Centrifuge for 10 to 30 min at 12,000 ×g. Discard the collection tube liquid, replenish the filter device to 500 µL with 1×PBS, and repeat 2 to 3 times until the ultrafiltrate is nearly colorless.
- Collect labeled product: add 0.2 mL 1×PBS to the filter device and pipet gently. Invert the filter device into a new collection tube and centrifuge at 1000 ×g for 2 min. The solution in the collection tube is the labeled protein.
(Optional) Determining the degree of labeling
- Set the absorbance scan range to 230 to 800 nm and use 1×PBS as the blank.
- Take 2 µL of labeled sample, scan the absorption spectrum from 230 to 800 nm, and record A280 and A405 (1 cm optical path). Use the full spectrum to exclude abnormal readings such as bubbles.
- Calculate DOS = (A405 × εIgG) / (εAFViolet 450 × (A280 − CF280 × A405)), using εIgG = 210000 L·mol-1·cm-1, εAFViolet 450 = 35000 L·mol-1·cm-1, and CF280 = 0.238.
- Calculate protein concentration (mg/mL) = (A280 − CF280 × A405) × 150000 / εIgG.
DOS=(A405×εIgG)/(εAFViolet 450 ×(A280−CF280×A405)); Protein concentration (mg/mL)=(A280−CF280×A405)×150000/εIgG
- DOS is the degree of substitution, the average number of dye molecules labeled per protein molecule.
- A405 is the absorbance of the dye at 405 nm, measured with a 1 cm optical path.
- A280 is the absorbance of the labeled protein at 280 nm, measured with a 1 cm optical path.
- CF280 is the correction coefficient for dye absorbance at 280 nm (0.238).
- εIgG is the molar extinction coefficient of IgG, 210,000 L·mol⁻¹·cm⁻¹. The manual's protein concentration formula uses this value.
- εdye is the molar extinction coefficient of the dye, 35,000 L·mol⁻¹·cm⁻¹.
- The protein concentration formula uses the constant 150000 as given in the manual.
- The manual does not describe a dilution factor for these calculations. Any dilution of the labeled sample must be accounted for separately.
What proteins can I label with this kit?
The kit labels proteins that contain primary amino groups, such as antibodies and other proteins. Sources cite IgG, Annexin V, protein A/G, 2019-nCov spike, NGAL, and some recombinant protein fragments. Use 0.1 to 1 mg of protein per labeling run.
How should I store the kit, the dissolved dye, and the labeled protein?
The unsealed kit can be stored at 2 to 8 °C for 1 year. Dissolved dye can be stored at -20 °C or -80 °C for 1 week. Labeled protein can be stored at 2 to 8 °C in the dark for 6 months with 0.05 to 0.2% ProClin 300 or 0.05% sodium azide and a stabilizer such as 0.1% BSA, or with an equal volume of glycerol at -20 °C for 6 months.
What should I do if the degree of labeling is low or high?
A low DOS is usually caused by interfering components such as Tris, glycine, sodium azide, or carrier proteins like BSA and gelatin, which must be removed first. A DOS greater than 10 indicates excessive labeling; reduce the amount of dye or the molar ratio, and make sure the protein concentration is above 0.5 mg/mL after labeling.
Which substances interfere with labeling?
Tris, glycine, amino acids, imidazole, sodium azide, thiomersal, and ProClin interfere with labeling. Carrier proteins such as BSA and gelatin also interfere. Excess DMF in the reaction also interferes, so use the minimum amount needed to dissolve the dye.
What instrument settings should I use to determine the degree of labeling?
Scan the absorbance spectrum from 230 nm to 800 nm, using 1× PBS as the blank. Take 2 µL of labeled sample and record A280 and A405 from the spectrum, using a 1 cm optical path. Measure the range of the spectrum rather than only the maximum value, and check the baseline.
How long does the labeling procedure take?
The whole process takes about 90 min. The labeling reaction is incubated at 37 °C for 30 min in the dark. Ultrafiltration steps take 10 to 30 min each at 12,000×g, and the recovery and collection steps take 2 min at 1,000×g.
| AFViolet 450 NHS ester: | -20 °C, protect from light; keep with desiccant |
| Labeling Buffer II: | 2 to 8 °C |
| DMF: | 2 to 8 °C, protect from light |
| 1×PBS (pH 7.4): | 2 to 8 °C |
| 1 M Tris (pH 8.7): | 2 to 8 °C |
| Filtration tubes: | Room temperature |
| Unsealed kit storage: | 2 to 8 °C for 1 year |
| Dissolved dye storage: | -20 °C or -80 °C for 1 week |
| Labeled protein (with 0.05 to 0.2% ProClin 300 or 0.05% sodium azide, plus 0.1% BSA): | 2 to 8 °C in the dark for 6 months |
| Labeled protein (with equal volume glycerol): | -20 °C for 6 months |
| Expiration: | 12 months |
| Shipping: | Ice bag |
Cautions
- For research use only. Not for use in diagnostic or therapeutic procedures.
- AFViolet 450 NHS ester is moisture sensitive. Equilibrate to room temperature before opening to prevent condensation, and do not mix the dye with water before use.
- Remove free amines (Tris, glycine, amino acids, ammonium ions, sodium azide) from the protein before labeling. Excess DMF can interfere with labeling.
- Carrier proteins such as BSA or gelatin will compete for the dye. Remove them before labeling.
- Do not exceed 1 mg protein per filter device. Overloading can cause leakage and low recovery.
- Centrifuge in the specified conditions; excessive speed can cause leakage. Do not pipette directly from the filter device after ultrafiltration; collect the sample by inverted centrifugation.
- For proteins not previously labeled with this kit, test a small amount first. Labeling may impair protein biological function in some cases.
- Consult the instrument's instructions for absorbance measurements.