100% Quality Guarantee
PhD-Level Technical Support
ATPase Activity Assay Kit typical standard curve
Key Features

ATPase Activity Assay Kit (MAES0234)

SKU MAES0234
Product Type Assay
Instrument Microplate Reader
Detection Method Colorimetric
Sample Type Animal Tissue, Cell
Sensitivity 0.06 U/L
Range 0.06-2.75 U/L
Assay Time 80 min
€351

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

ATPase Activity Assay Kit

The ATPase Activity Assay Kit (MAES0234) measures ATPase activity in animal tissue and cell homogenates. ATPase hydrolyzes ATP to ADP and inorganic phosphorus, and the kit quantifies the inorganic phosphorus produced per unit time by colorimetric detection. It is intended for Research Use Only.

ATPase is an enzyme that catalyzes the hydrolysis of adenosine triphosphate (ATP) to adenosine diphosphate (ADP) and inorganic phosphorus. ATP is described as an important high-energy compound in organisms, and ATPase activity helps maintain the balance of cell membrane potential and ions. This kit measures ATPase activity in animal tissue and cell samples, with activity expressed as inorganic phosphorus produced per unit time.

The kit is listed under the Oxidative Stress research area on the product page. Publications cited in the manual examine mitochondrial dynamics in cerebral ischemia-reperfusion injury, ferroptosis and neurotoxicity induced by manganese, senescence of bone marrow mesenchymal stem cells in ovariectomized rats, and sepsis-induced acute respiratory distress syndrome. These models involve energy metabolism and redox balance, which is why ATPase activity is measured in them.

The method is colorimetric and quantifies inorganic phosphorus released during ATP hydrolysis. Sample is incubated with buffer and substrate working solution at 37 °C for 30 min, and acid reagent stops the reaction. Supernatant is then mixed with chromogenic working solution, incubated at room temperature for 2 min, treated with acid reagent, and held for 10 min in the dark. Optical density is read at 640 nm, which the manual identifies as the optimum wavelength within 630-640 nm.

Suitable samples are animal tissue homogenates and cell lysates. Tissue (initial recommendation 50 mg) is homogenized in 450 µL normal saline (0.9% NaCl) at 4 °C, and cells (initial recommendation 2×10^6) are homogenized in 400 µL normal saline using an ultrasonic cell disruptor at 4 °C. Homogenates are centrifuged at 10000×g for 10 min at 4 °C, and the supernatant is kept on ice until testing. Kit reagents are stored at 2-8 °C for 12 months, with the substrate and chromogenic agent A protected from light. Substrate working solution is stable for 7 days at 2-8 °C, and chromogenic working solution must be used within 10 hours of preparation.

The analytical sensitivity is 0.06 U/L, and the detection range is 0.06-2.75 U/L. Intra-assay precision was 3.8-4.4% CV across three human serum samples assayed in replicates of 20. Inter-assay precision was 4.6-5.2% CV across 20 assays in duplicate by three operators. Recovery at low, middle, and high concentrations ranged from 91% to 98%, with an average of 95%.