Description
beta-N-Acetylglucosaminidase (NAG) Activity Assay Kit
The beta-N-Acetylglucosaminidase (NAG) Activity Assay Kit (MAES0279) measures NAG enzyme activity in serum, plasma, animal tissue and cell samples. NAG hydrolyzes a substrate to produce p-nitrophenol, and activity is calculated from the change in absorbance at 400 nm. The kit is for Research Use Only and is commonly used in liver and renal function research.
β-N-Acetylglucosaminidase (NAG) is a glycoside hydrolase that cleaves β-linked N-acetylglucosamine residues from glycoconjugate substrates. It is measured in serum, plasma, animal tissue, and cell samples. This kit quantifies NAG catalytic activity rather than enzyme mass, so results are reported in units per liter (U/L) for serum and plasma and in units per gram of protein (U/gprot) for tissue and cell lysates.
The product page lists liver and renal function as the research area for this kit. Researchers use NAG activity as a readout in liver and kidney studies, and the manual provides dilution guidance for mouse liver, kidney, heart, and lung tissue homogenates. The kit is labeled for research use only and must not be used for clinical diagnosis.
The assay is colorimetric. NAG hydrolyzes the substrate to produce p-nitrophenol, which has a maximum absorption peak at about 400 nm. Samples are mixed with a measuring working solution, prepared from buffer solution and substrate solution, and incubated at 37°C for 10 minutes. Chromogenic agent is then added to each well, and absorbance is read at 400 nm on a microplate reader. Activity is calculated from the change in absorbance relative to a control well that contains sample but no substrate.
Serum and plasma are tested directly. If they are not tested the same day, they can be stored at -80°C for up to one month. Tissue is washed in cold PBS (0.01 M, pH 7.4) and homogenized at 4°C in normal saline (0.9% NaCl), while adherent or suspension cells are washed in PBS and disrupted by ultrasonication at 4°C. Lysates are centrifuged at 10000×g for 10 minutes at 4°C, and the supernatant is kept on ice for testing. Protein concentration of each supernatant must be measured separately for tissue and cell calculations.
Reported performance includes an analytical sensitivity of 0.76 U/L, determined by adding two standard deviations to the mean OD of the zero standard assayed 20 times. The detection range is 0.76–49.51 U/L. Intra-assay CV ranged from 3.2% to 5.0%, and inter-assay CV ranged from 4.6% to 6.8% across three human serum samples. Recovery at low, middle, and high standard concentrations averaged 96%, with individual values of 92% to 98%.
| Product name: | beta-N-Acetylglucosaminidase (NAG) Activity Assay Kit |
| SKU: | MAES0279 |
| Synonyms: | NAG |
| Assay type: | Enzyme activity |
| Sample types: | Serum, plasma, animal tissue, cell |
| Detection method: | Colorimetric |
| Detection instrument: | Microplate reader (390-415 nm; optimum 400 nm) |
| Sensitivity: | 0.76 U/L |
| Detection range: | 0.76–49.51 U/L |
| Intra-assay CV: | 3.2-5.0% |
| Inter-assay CV: | 4.6-6.8% |
| Research area: | Liver and renal function |
| Use: | Research Use Only |
| Detection method: | Colorimetric |
| Wavelength: | 400 nm (reading range 390-415 nm) |
| Sensitivity: | 0.76 U/L |
| Detection range: | 0.76–49.51 U/L |
| Intra-assay CV: | 3.2-5.0% |
| Inter-assay CV: | 4.6-6.8% |
| Sample volume per well: | 20 µL |
| Reaction temperature: | 37°C |
| Reaction time: | 10 min |
| Valid period: | 12 months |
- Colorimetric endpoint readout of p-nitrophenol at 400 nm on a microplate reader (390-415 nm)
- Detection range 0.76–49.51 U/L with analytical sensitivity of 0.76 U/L
- Validated for serum, plasma, animal tissue homogenates and cell lysates
- Intra-assay CV: 3.2-5.0%; Inter-assay CV: 4.6-6.8%
- Includes standard powder for a 0–0.5 mmol/L standard curve
- Requires a 37°C incubator and a 10-minute reaction
NAG catalyzes the conversion of the substrate to p-nitrophenol, which has an absorption maximum at about 400 nm. After a 10-minute reaction at 37°C, the reaction is stopped by adding chromogenic agent, and the absorbance at 400 nm is read. NAG activity is calculated from the change in absorbance (ΔA400) against a standard curve.
- Measuring NAG activity in serum and plasma samples for liver and renal function studies
- Quantifying NAG activity in mouse liver, kidney, heart and lung tissue homogenates
- Assessing NAG activity in cell lysates normalized to total protein
- Comparing NAG activity across experimental groups in animal tissue studies
| Component | Storage |
| Reagent 1: Buffer Solution | -20°C, 12 months |
| Reagent 2: Substrate Solution (shade from light) | -20°C, 12 months, protect from light |
| Reagent 3: Chromogenic Agent | -20°C, 12 months |
| Reagent 4: Standard Powder (shade from light) | -20°C, 12 months, protect from light |
| Microplate | Room temperature |
| Plate sealer | Room temperature |
| Sample layout sheet | Room temperature |
- Microplate reader capable of 390-415 nm detection (optimum 400 nm)
- 37°C incubator
- Double distilled water
- Normal saline (0.9% NaCl)
- PBS (0.01 M, pH 7.4) for tissue and cell washing
- Homogenizer (Dounce homogenizer for tissue; ultrasonic cell disruptor for cells), kept at 4°C
- Refrigerated centrifuge capable of 10000×g at 4°C
- Protein concentration assay for tissue and cell supernatants
- Precision pipettes and microplate mixer
Serum/plasma
- Detect serum or plasma directly without pretreatment.
- If not tested on the same day, store serum or plasma at -80°C for up to one month.
- Dilution factors: human serum, 1; rat plasma, 1; bovine serum, 2-3.
- Diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).
- For other sample types, perform a pretest to confirm the dilution factor.
Tissue
- Harvest the amount of tissue needed for each assay (initial recommendation: 20 mg).
- Wash tissue in cold PBS (0.01 M, pH 7.4).
- Homogenize 20 mg tissue in 180 µL normal saline (0.9% NaCl) with a Dounce homogenizer at 4°C. This yields a 10% homogenate.
- Centrifuge at 10000×g for 10 minutes at 4°C to remove insoluble material.
- Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant separately for use in the calculation.
- Dilution factors for 10% homogenates: mouse liver, kidney, heart, and lung, 3-5 each. Dilute with normal saline (0.9% NaCl).
Cells (adherent or suspension)
- Harvest the number of cells needed for each assay (initial recommendation: 1×10^6 cells).
- Wash cells with PBS (0.01 M, pH 7.4).
- Homogenize 1×10^6 cells in 200 µL normal saline (0.9% NaCl) with an ultrasonic cell disruptor at 4°C.
- Centrifuge at 10000×g for 10 minutes at 4°C to remove insoluble material.
- Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant separately for use in the calculation.
- Dilution factors: 6×10^6 CHO cells, 1; 0.6×10^6 293T/17 cells, 1. Diluent is normal saline (0.9% NaCl).
Reagent preparation
- Equilibrate all reagents to room temperature before use.
- Prepare measure working solution fresh on the day of use by mixing buffer solution and substrate solution at 140 µL and 40 µL per 180 µL (4:1). Use within 1 day.
- Prepare 20 mmol/L standard solution: dissolve one vial of standard powder in 1 mL double distilled water and heat at 40°C for 3 min, protected from light, until dissolved. Aliquot and store at -20°C for up to 3 months.
- Prepare 0.5 mmol/L standard: dilute 20 µL of 20 mmol/L standard with 780 µL double distilled water and mix well. Prepare on the day of use.
- Prepare the standard curve fresh for each assay using 0.5 mmol/L standard diluted with double distilled water (0, 0.1, 0.15, 0.2, 0.3, 0.35, 0.4, 0.5 mmol/L; 0, 40, 60, 80, 120, 140, 160, 200 µL of 0.5 mmol/L standard with 200, 160, 140, 120, 80, 60, 40, 0 µL water, respectively). Discard working dilutions after use.
Sample preparation
- Serum and plasma: assay directly. If not assayed the same day, store at -80°C for up to 1 month.
- Tissue: wash in cold PBS, homogenize 20 mg tissue in 180 µL normal saline with a Dounce homogenizer at 4°C, centrifuge at 10000×g for 10 min at 4°C, and keep the supernatant on ice.
- Cells (adherent or suspension): wash with PBS, homogenize 1×10^6 cells in 200 µL normal saline with an ultrasonic cell disruptor at 4°C, centrifuge at 10000×g for 10 min at 4°C, and keep the supernatant on ice.
- Determine protein concentration of tissue and cell supernatants before calculating activity.
- Dilute samples as needed. Recommended dilution factors: 10% mouse liver, kidney, heart or lung tissue homogenate 3-5; rat plasma 1; human serum 1; bovine serum 2-3; 6×10^6 CHO cells 1; 0.6×10^6 293T/17 cells 1. Diluent is normal saline or PBS (0.01 M, pH 7.4). For other sample types, run a pretest to confirm the dilution factor.
Assay procedure
- Add 20 µL of each standard to standard wells, 20 µL of sample to sample wells, and 20 µL of sample to control wells.
- Add 160 µL of measure working solution to standard and sample wells. Add 160 µL of buffer solution to control wells.
- Mix for 5 s and incubate at 37°C for 10 min.
- Add 100 µL of chromogenic agent to each well.
- Mix for 5 s and read the OD at 400 nm on the microplate reader.
Calculation
- Average duplicate readings for each standard. Subtract the mean OD of the blank (standard 0 mmol/L) from all standard readings to obtain absolute OD values.
- Plot absolute OD (y) against standard concentration in mmol/L (x) and fit a linear standard curve (y = ax + b).
- Serum or plasma: NAG activity (U/L) = (ΔA400 − b) ÷ a ÷ T × f × 1000, where T = 10 min and f = sample dilution factor. One unit is the amount of NAG that produces 1 µmol of product per minute at 37°C per liter of sample.
- Tissue or cell: NAG activity (U/gprot) = (ΔA400 − b) ÷ a ÷ T × f ÷ Cpr × 1000, where Cpr is the protein concentration of the supernatant in gprot/L.
- ΔA400 = A(sample) − A(control).
Serum/plasma: NAG activity (U/L) = (∆A400-b) ÷ a ÷ T × f × 1000 Tissue/cell: NAG activity (U/gprot) = (∆A400-b) ÷ a ÷ T × f ÷ Cpr × 1000
- Standard curve: y = ax + b, where y is the absolute OD value (mean standard OD minus the blank standard OD) and x is the standard concentration in mmol/L. Calculate the curve with graphing software or Excel.
- ∆A400 = A400 sample well − A400 control well.
- a = slope and b = intercept of the standard curve.
- T = reaction time, 10 minutes.
- f = dilution factor of the sample before testing.
- Cpr = protein concentration of the sample in g prot/L (tissue and cell calculations only).
- 1000 converts mmol/L to µmol/L (1 mmol/L = 1000 µmol/L).
- Definition: 1 unit is the amount of NAG that hydrolyzes the substrate to produce 1 µmol of product per minute at 37°C per liter of serum or plasma, or per gram of tissue or cell protein for tissue and cell samples.
How should serum and plasma be stored before testing?
Serum and plasma can be tested directly. If they are not tested on the same day, store them at -80°C for up to one month.
How should the kit reagents be stored, and how long are they stable?
Store all reagents at -20°C for 12 months. Reagent 2 (substrate solution) and Reagent 4 (standard powder) must also be protected from light. Prepare the measuring working solution fresh and use it within 1 day. Aliquoted 20 mmol/L standard stock stored at -20°C is stable for 3 months.
What is the detection range, and what should I do if a sample reads out of range?
The detection range is 0.76–49.51 U/L. If the concentration is not within the detection range, perform an extra dilution or concentration of the sample. For sample types not listed in the manual, run a pretest first.
What instrument settings are required?
Use a microplate reader with a 390–415 nm filter range, and read absorbance at the optimum wavelength of 400 nm. Incubate the reaction at 37°C.
How long does the assay take?
After the sample and working solution are mixed, the reaction incubates at 37°C for 10 minutes. Chromogenic agent is then added, the plate is mixed for 5 seconds, and absorbance is read at 400 nm.
Which factors can affect results?
Results depend closely on reagent handling, operation, and environment. Pipetting technique and temperature can change the standard curve, so run a fresh standard curve with each assay. Protect light-sensitive reagents from light.
| Storage temperature: | -20°C |
| Shelf life: | 12 months |
| Light protection: | Store substrate solution and standard powder protected from light |
| Diluted standard (20 mmol/L): | Aliquot; store at -20°C for up to 3 months |
| Serum and plasma samples: | Store at -80°C for up to 1 month if not assayed the same day |
| Measure working solution: | Use within 1 day of preparation |
Notes
- For Research Use Only. Not for use in clinical diagnosis or therapeutic procedures.
- Do not mix reagents from different kits.
- Centrifuge small-volume reagents before use to ensure sufficient volume is recovered.
- Wear a lab coat and gloves when handling samples and reagents.
- If a sample falls outside the detection range, dilute or concentrate it and re-assay.
- Run a pretest for any sample type not listed in the dilution table.
- Results are sensitive to reagent handling, operator technique, and environmental conditions.