Description
ATPase Activity Assay Kit
The ATPase Activity Assay Kit (MAES0234) measures ATPase activity in animal tissue and cell homogenates. ATPase hydrolyzes ATP to ADP and inorganic phosphorus, and the kit quantifies the inorganic phosphorus produced per unit time by colorimetric detection. It is intended for Research Use Only.
ATPase is an enzyme that catalyzes the hydrolysis of adenosine triphosphate (ATP) to adenosine diphosphate (ADP) and inorganic phosphorus. ATP is described as an important high-energy compound in organisms, and ATPase activity helps maintain the balance of cell membrane potential and ions. This kit measures ATPase activity in animal tissue and cell samples, with activity expressed as inorganic phosphorus produced per unit time.
The kit is listed under the Oxidative Stress research area on the product page. Publications cited in the manual examine mitochondrial dynamics in cerebral ischemia-reperfusion injury, ferroptosis and neurotoxicity induced by manganese, senescence of bone marrow mesenchymal stem cells in ovariectomized rats, and sepsis-induced acute respiratory distress syndrome. These models involve energy metabolism and redox balance, which is why ATPase activity is measured in them.
The method is colorimetric and quantifies inorganic phosphorus released during ATP hydrolysis. Sample is incubated with buffer and substrate working solution at 37 °C for 30 min, and acid reagent stops the reaction. Supernatant is then mixed with chromogenic working solution, incubated at room temperature for 2 min, treated with acid reagent, and held for 10 min in the dark. Optical density is read at 640 nm, which the manual identifies as the optimum wavelength within 630-640 nm.
Suitable samples are animal tissue homogenates and cell lysates. Tissue (initial recommendation 50 mg) is homogenized in 450 µL normal saline (0.9% NaCl) at 4 °C, and cells (initial recommendation 2×10^6) are homogenized in 400 µL normal saline using an ultrasonic cell disruptor at 4 °C. Homogenates are centrifuged at 10000×g for 10 min at 4 °C, and the supernatant is kept on ice until testing. Kit reagents are stored at 2-8 °C for 12 months, with the substrate and chromogenic agent A protected from light. Substrate working solution is stable for 7 days at 2-8 °C, and chromogenic working solution must be used within 10 hours of preparation.
The analytical sensitivity is 0.06 U/L, and the detection range is 0.06-2.75 U/L. Intra-assay precision was 3.8-4.4% CV across three human serum samples assayed in replicates of 20. Inter-assay precision was 4.6-5.2% CV across 20 assays in duplicate by three operators. Recovery at low, middle, and high concentrations ranged from 91% to 98%, with an average of 95%.
| Product Name: | ATPase Activity Assay Kit |
| SKU: | MAES0234 |
| Sample Type: | Animal tissue, cell homogenate |
| Assay Type: | Enzyme activity detection |
| Detection Method: | Colorimetric |
| Instrument: | Microplate reader (630-640 nm; optimum 640 nm) |
| Assay Time: | 80 min (1 h 20 min) |
| Research Area: | Oxidative Stress |
| Detection Method: | Colorimetric (inorganic phosphorus) |
| Measuring Wavelength: | 630-640 nm (optimum 640 nm) |
| Sensitivity: | 0.06 U/L |
| Detection Range: | 0.06-2.75 U/L |
| Intra-assay CV: | 3.8-4.4% |
| Inter-assay CV: | 4.6-5.2% |
| Recovery: | 91-98% (average 95%) |
- Colorimetric endpoint read at 640 nm (optimum wavelength) on a microplate reader
- Sensitivity 0.06 U/L; detection range 0.06-2.75 U/L
- Validated for animal tissue and cell homogenate samples
- Total assay time approximately 80 min (1 h 20 min)
- Reagents stored at 2-8°C with 12-month valid period
ATPase catalyzes the hydrolysis of adenosine triphosphate (ATP) to adenosine diphosphate (ADP) and inorganic phosphorus. The activity of ATPase is determined by the inorganic phosphorus production per unit time. Sample and control tubes are incubated with substrate, then acid reagent is added and the inorganic phosphorus is detected with a chromogenic working solution (Chromogenic Agent A and Chromogenic Agent B). Absorbance is read at 640 nm and converted to concentration using a standard curve.
- Quantifying ATPase activity in animal tissue homogenates (rat and mouse liver, kidney, heart, spleen, and lung listed in the dilution guidance)
- Measuring ATPase activity in cell homogenates (293T cell example in the protocol)
- Comparing ATPase activity across tissues or cell samples under experimental conditions
- Oxidative stress research workflows involving ATPase activity measurements
| Component | Storage |
| Reagent 1: Buffer Solution | 2-8°C, 12 months |
| Reagent 2: Substrate Powder | 2-8°C, 12 months, protect from light |
| Reagent 3: Acid Reagent | 2-8°C, 12 months |
| Reagent 4: Chromogenic Agent A | 2-8°C, 12 months, protect from light |
| Reagent 5: Chromogenic Agent B | 2-8°C, 12 months |
| Reagent 6: 10 mmol/L Standard | 2-8°C, 12 months |
| Microplate (96-well) | No storage requirement |
- Microplate reader (630-640 nm; optimum 640 nm)
- Incubator (37°C and room temperature use)
- Vortex mixer
- Centrifuge (capable of 3500×g and 10000×g)
- Double distilled water
- Normal saline (0.9% NaCl)
- PBS (0.01 M, pH 7.4) for washing samples
- Homogenizer: Dounce homogenizer for tissue; ultrasonic cell disruptor for cells
- Ice or 4°C cold storage for samples
- 1.5 mL microcentrifuge (EP) tubes
- Protein concentration assay for sample normalization
Animal tissue homogenate
- Harvest the amount of tissue needed for each assay (initial recommendation 50 mg).
- Wash tissue in cold PBS (0.01 M, pH 7.4).
- Homogenize 50 mg tissue in 450 µL normal saline (0.9% NaCl) with a Dounce homogenizer at 4 °C to prepare a 10% homogenate.
- Centrifuge at 10000×g for 10 min at 4 °C to remove insoluble material. Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant, which is required for the calculation.
- Dilute 10% rat liver, kidney, heart, spleen, or lung homogenates, and 10% mouse liver, spleen, lung, or kidney homogenates, 5-10-fold in normal saline (0.9% NaCl). The example analysis used 5-fold dilution.
- For other sample types, perform a pretest to confirm the dilution factor. The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).
Cells (adherent or suspension)
- Harvest the number of cells needed for each assay (initial recommendation 2×10^6 cells).
- Wash cells with PBS (0.01 M, pH 7.4).
- Homogenize 2×10^6 cells in 400 µL normal saline (0.9% NaCl) with an ultrasonic cell disruptor at 4 °C.
- Centrifuge at 10000×g for 10 min at 4 °C to remove insoluble material. Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant, which is required for the calculation.
- For 293T cells, the recommended dilution factor is 1 (undiluted). For other cell types, perform a pretest to confirm the dilution factor.
Reagent preparation
- Equilibrate all reagents to room temperature before use.
- Substrate working solution: dissolve one vial of Substrate Powder in 10 mL double distilled water and mix well. Store at 2-8°C for 7 days, protected from light.
- Chromogenic working solution: for each well, mix 75 µL Chromogenic Agent A with 25 µL Chromogenic Agent B (100 µL per well). Stand at 37°C for 1 h. Prepare on the spot and use within 10 h.
- 0.1 mmol/L standard: dilute 10 µL of 10 mmol/L Standard with 990 µL double distilled water. Prepare on the spot.
- Standard curve: prepare a fresh set of standards and discard working dilutions after use. Dilute the 0.1 mmol/L standard with double distilled water as follows: 0, 20, 40, 60, 100, 120, 160, and 200 µL of 0.1 mmol/L standard, with 200, 180, 160, 140, 100, 80, 40, and 0 µL double distilled water, giving 0, 0.01, 0.02, 0.03, 0.05, 0.06, 0.08, and 0.10 mmol/L.
Sample preparation
- Tissue: wash tissue in cold PBS (0.01 M, pH 7.4). Homogenize 50 mg tissue in 450 µL normal saline (0.9% NaCl) with a Dounce homogenizer at 4°C. Centrifuge at 10000×g for 10 min at 4°C. Collect the supernatant and keep on ice.
- Cells (adherent or suspension): wash with PBS (0.01 M, pH 7.4). Homogenize 2×10^6 cells in 400 µL normal saline (0.9% NaCl) with an ultrasonic cell disruptor at 4°C. Centrifuge at 10000×g for 10 min at 4°C. Collect the supernatant and keep on ice.
- Determine the protein concentration of the supernatant separately; protein concentration (g prot/L) is required for calculation.
- Dilution: dilute samples in normal saline (0.9% NaCl). Recommended dilution factor for 10% rat and mouse tissue homogenates is 5-10; for 293T cell samples, 1. For other sample types, perform a pretest to confirm the dilution factor.
Enzymatic reaction
- Label a control tube and a sample tube (1.5 mL EP tubes). Add 160 µL double distilled water to each tube.
- Add 100 µL sample to the sample tube.
- Add 260 µL Buffer Solution to each tube.
- Add 80 µL substrate working solution to each tube.
- Mix fully and incubate at 37°C for 30 min.
- Add 100 µL Acid Reagent to each tube and mix fully.
- Add 100 µL sample to the control tube, mix fully, and centrifuge at 3500×g for 10 min. Use the supernatant for detection.
Chromogenic reaction
- Add 30 µL of each standard to the standard wells, 30 µL control supernatant to the control well, and 30 µL sample supernatant to the sample well.
- Add 100 µL chromogenic working solution to each well.
- Mix on the microplate reader for 5 s, then incubate at room temperature for 2 min.
- Add 100 µL Acid Reagent to each well.
- Mix on the microplate reader for 5 s, then incubate at room temperature for 10 min with shading light.
- Read the OD of each well at 640 nm.
Calculation
- Standard curve: average duplicate readings for each standard. Subtract the mean blank (standard 1, 0 mmol/L) OD from all standard readings to obtain absolute OD. Plot absolute OD (y) against concentration in mmol/L (x) and fit a linear equation (y = ax + b).
- ATPase activity (U/g prot) = (ΔA − b) ÷ a ÷ Cpr ÷ T × f × 1000, where ΔA = OD sample minus OD control, T = incubation time (30 min), Cpr = protein concentration of the sample (g prot/L), f = sample dilution factor, and 1000 converts mmol/L to µmol/L.
- One unit is defined as the amount of ATPase in 1 g tissue or cell protein that produces 1 µmol of product per minute at 37°C.
ATPase activity (U/gprot) = (ΔA − b) ÷ a ÷ Cpr ÷ T × f × 1000
- Standard curve: y = ax + b, where y is the absolute OD value (standard OD minus the mean blank OD) and x is the standard concentration in mmol/L. Use a as the slope and b as the intercept.
- ΔA = OD sample − OD control.
- T = incubation time of the enzymatic reaction, 30 min.
- Cpr = protein concentration of the sample, in gprot/L.
- f = dilution factor of the sample applied before the test. For undiluted samples, f = 1.
- 1000 converts 1 mmol/L to 1000 µmol/L, so the result is expressed per gram of protein.
- Definition: 1 unit is the amount of ATPase in 1 g tissue or cell protein that hydrolyzes substrate to produce 1 µmol of product per minute at 37 °C.
- Worked example from the manual: with y = 5.5215x − 0.0044, control OD 0.639, sample OD 0.784, Cpr 7.75 gprot/L, and 5-fold dilution, the activity is 0.62 U/gprot.
What sample types can be measured with this kit?
The kit measures ATPase activity in animal tissue and cell samples. Tissue must be homogenized to 10% in normal saline and clarified by centrifugation before testing. Sample types not listed in the manual should be pretested to confirm the dilution factor.
How should the kit and working solutions be stored?
Kit reagents are stored at 2-8 °C for 12 months, with the substrate and chromogenic agent A protected from light. Substrate working solution is stable for 7 days at 2-8 °C protected from light. Chromogenic working solution must be prepared on the spot and used within 10 hours.
What should I do if my sample is outside the detection range?
The detection range is 0.06-2.75 U/L. If the concentration is not within this range, take an extra dilution or concentration of the sample. Recommended dilution for listed tissue homogenates is 5-10-fold.
What factors affect results?
Results are closely related to reagent condition, operation, and environment. Reserve sufficient sample before testing, because the sample consumption from the assay is not covered by the guarantee. Reagents from different kits must not be mixed.
What instrument settings are needed?
Read the optical density on a microplate reader at 630-640 nm, with 640 nm as the optimum wavelength. The product page lists the detection wavelength as 630-650 nm.
What is the total assay time?
The assay time is 1 h 20 min. This includes the 30 min enzymatic reaction at 37 °C and the chromogenic reaction steps.
| Storage: | 2-8°C; certain reagents must be kept protected from light |
| Shelf Life: | 12 months |
Notes
- For research use only; do not use in clinical diagnosis.
- Store each reagent strictly under the listed conditions and do not mix reagents from different kits.
- Equilibrate all reagents to room temperature before use.
- Centrifuge small-volume reagents before use to ensure sufficient amounts are recovered.
- Prepare chromogenic working solution fresh and use it within 10 hours; substrate working solution is stable for 7 days at 2-8°C protected from light.
- Run the chromogenic reaction step with protected from light, as specified in the operating steps.