Description
6-Phosphogluconate Dehydrogenase (6-PGDH) Activity Colorimetric Assay Kit
The 6-Phosphogluconate Dehydrogenase (6-PGDH) Activity Colorimetric Assay Kit (MAES0513) measures 6-PGDH enzyme activity in serum, plasma, animal tissue, plant tissue, and cell samples. The enzymatic product reacts with a chromogenic agent to give a color with maximum absorbance at 450 nm, and activity is calculated from the change in OD450 over a 10 min incubation at 37°C. Researchers use the kit to study the pentose phosphate pathway, NADPH production, and 6-PGDH-associated tumor signaling. This product is for Research Use Only.
6-Phosphogluconate dehydrogenase (6-PGDH) is the rate-limiting enzyme of the pentose phosphate pathway. This pathway is responsible for the production of NADPH, and the sources link it to energy balance, growth rate, and cell viability. Because 6-PGDH controls the rate of this pathway, its activity indicates how much metabolic flux passes through the NADPH-producing branch. Measuring the enzyme activity therefore gives a functional readout of this pathway.
Researchers measure 6-PGDH because it is associated with several tumor signaling pathways, including the epidermal growth factor signaling pathway and the nuclear factor E2-related factor signaling pathway. The listed research area for this kit is glycolysis and lipid metabolism. Published literature that cites this product pairs it with glucose-6-phosphate assays, glucose-6-phosphate dehydrogenase assays, and NADP+/NADPH measurements, which places the enzyme within the same NADPH-generating network under study.
The assay is colorimetric. 6-PGDH in the sample acts on its substrate, and the product generated reacts with a chromogenic agent to form a chromogenic substance with maximum absorption at 450 nm. The working solution combines buffer, substrate, coenzyme working solution, and chromogenic agent. For each well, 20 µL of standard or sample is mixed with 200 µL of working solution, and the optical density (OD) is read at 450 nm (A1). After a 10 min incubation at 37°C, the OD is read again (A2). The change in absorbance (A2 − A1) is used to calculate activity against a standard curve. A microplate reader with a 440-460 nm measurement range is required, with 450 nm as the optimum wavelength.
The kit is intended for serum, plasma, animal tissue, plant tissue, and cell samples. Serum and plasma are assayed directly. Tissue samples are washed in cold PBS, homogenized, and centrifuged, and cell samples are washed in PBS, homogenized by ultrasonic disruption, and centrifuged. In both cases, the supernatant is kept on ice for detection. Listed tissues include mouse liver, muscle, heart, brain, and kidney, as well as broccoli, potato, and corn. Listed cell types are HeLa and 293T cells. Cell extracts should be detected on the same day they are prepared.
The reported analytical sensitivity is 1.26 U/L, and the detection range is 1.26-101.85 U/L. Intra-assay precision, based on three human serum samples assayed in replicate, ranged from 2.9% to 4.6% CV. Inter-assay precision, from 20 assays in duplicate by three operators, ranged from 5.9% to 9.4% CV. Recovery was 95.0%, 105.0%, and 102.0% at low, middle, and high concentrations, with an average of 100.7%. Standard OD values can vary with operator, pipetting technique, and temperature, so the provided standard curve is for reference only. For research use only.
| Product: | 6-Phosphogluconate Dehydrogenase (6-PGDH) Activity Colorimetric Assay Kit |
| SKU: | MAES0513 |
| Analyte: | 6-Phosphogluconate dehydrogenase (6-PGDH) activity |
| Detection method: | Colorimetric |
| Sample types: | Serum, plasma, animal tissue, plant tissue, cells |
| Assay time: | 50 min |
| Research area: | Glycolysis and lipid metabolism |
| Detection method: | Colorimetric |
| Wavelength: | 450 nm (maximum absorbance) |
| Detection instrument: | Microplate reader (440-460 nm) |
| Sensitivity: | 1.26 U/L |
| Detection range: | 1.26-101.85 U/L |
| Sample volume: | 20 µL |
| Assay time: | 50 min |
| Intra-assay CV: | 2.9-4.6% |
| Inter-assay CV: | 5.9-9.4% |
| Recovery: | 100.7% (average) |
- Colorimetric readout at 450 nm on a microplate reader (440-460 nm)
- Detection range 1.26-101.85 U/L with a sensitivity of 1.26 U/L
- Works with serum, plasma, animal tissue, plant tissue, and cell samples
- Requires 20 µL of sample per well and a 50 min assay time
- Intra-assay CV 2.9-4.6% and inter-assay CV 5.9-9.4%
The 6-PGDH catalytic substrate is converted to a product that reacts with a chromogenic agent to generate a colored substance with maximum absorbance at 450 nm. Absorbance is read at 450 nm before and after a 10 min incubation at 37°C. The change in OD450 (ΔA450), corrected by the standard curve slope and intercept, gives 6-PGDH activity.
- Measuring 6-PGDH activity in pentose phosphate pathway studies
- Studying NADPH production and energy balance in tissue and cell samples
- Investigating 6-PGDH activity in epidermal growth factor and Nrf2 tumor signaling research
- Assessing growth rate and cell viability in relation to 6-PGDH activity
- Comparing 6-PGDH activity across serum, plasma, animal tissue, plant tissue, and cell samples
| Component | Quantity | Storage |
| Buffer (Reagent 1), solution | 1 vial | -20°C, 12 months, protect from light |
| Substrate (Reagent 2), solution | 1 vial | -20°C, 12 months, protect from light |
| Coenzyme (Reagent 3), powder | 1 vial | -20°C, 12 months, protect from light |
| Chromogenic Agent (Reagent 4), solution | 1 vial | -20°C, 12 months, protect from light |
| Standard (Reagent 5), powder | Powder vials | -20°C, 12 months, protect from light |
| Microplate | Included | Room temperature |
| Plate sealer | Included | Room temperature |
| Sample layout sheet | Included | Room temperature |
- Microplate reader capable of 440-460 nm reading (450 nm optimum)
- 37°C incubator
- PBS (0.01 M, pH 7.4)
- Double distilled water
- Normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4) as sample diluent
- Dounce homogenizer (tissue) or ultrasonic cell disruptor (cells)
- Centrifuge capable of 10000 ×g at 4°C
- Ice and cold PBS for sample harvest
- Pipettes and tips
Serum/plasma
- Detect serum and plasma samples directly.
- Recommended dilution factor: human serum 1; rat plasma 1; fetal bovine plasma 1 (undiluted for these listed samples).
- Diluent for samples is PBS (0.01 M, pH 7.4) or normal saline (0.9% NaCl). For other sample types, perform a pretest to confirm the dilution factor.
Tissue (animal and plant)
- Harvest the amount of tissue needed for each assay (initial recommendation 20 mg).
- Wash tissue in cold PBS (0.01 M, pH 7.4).
- Homogenize 20 mg tissue in 180 µL PBS (0.01 M, pH 7.4) with a dounce homogenizer at 4°C.
- Centrifuge at 10000 × g for 10 min at 4°C to remove insoluble material.
- Collect the supernatant and keep it on ice for detection.
- Recommended dilution factor for 10% homogenates: mouse liver 1-10; mouse muscle 1-10; mouse heart 1-10; mouse brain 1-10; mouse kidney 2-10; broccoli 1; potato 1; corn 1-10.
- Dilute with PBS (0.01 M, pH 7.4). For other tissue types, perform a pretest to confirm the dilution factor.
Cells
- Harvest the number of cells needed for each assay (initial recommendation 1 × 10^6 cells).
- Wash cells with PBS (0.01 M, pH 7.4).
- Homogenize 1 × 10^6 cells in 200 µL PBS (0.01 M, pH 7.4) with an ultrasonic cell disruptor at 4°C.
- Centrifuge at 10000 × g for 10 min at 4°C to remove insoluble material.
- Collect the supernatant and keep it on ice. Detect on the same day.
- Recommended dilution factor: HeLa cells (1 × 10^6) 2-10; 293T cells (1 × 10^6) 8-25.
- Dilute with PBS (0.01 M, pH 7.4). For other cell types, perform a pretest to confirm the dilution factor.
Reagent preparation
- Equilibrate all reagents to 25°C before use.
- Coenzyme working solution: dissolve the coenzyme in 850 µL double distilled water and mix fully. Aliquot and store at -20°C for up to 1 week, protected from light.
- Working solution: prepare fresh on the day of the assay, protected from light. Example for 400 µL: 250 µL buffer, 20 µL substrate, 30 µL coenzyme working solution, and 100 µL chromogenic agent. Mix well.
- 1000 µmol/L standard solution: dissolve the standard in 750 µL double distilled water and mix fully. Aliquot and store at -20°C for up to 1 week, protected from light.
- Standard curve: prepare fresh standards each time by diluting the 1000 µmol/L standard with double distilled water to 0, 50, 100, 200, 400, 600, 800, and 1000 µmol/L (standard volumes 0, 10, 20, 40, 80, 120, 160, and 200 µL; water 200, 190, 180, 160, 120, 80, 40, and 0 µL, respectively, for a 200 µL total). Discard working standards after use.
Sample preparation
- Plasma or serum: assay directly.
- Tissue: wash in cold PBS (0.01 M, pH 7.4). Homogenize 20 mg tissue in 180 µL PBS with a Dounce homogenizer at 4°C. Centrifuge at 10000 ×g for 10 min at 4°C. Keep the supernatant on ice.
- Cells: wash about 1×10^6 cells with PBS (0.01 M, pH 7.4). Homogenize in 200 µL PBS with an ultrasonic cell disruptor at 4°C. Centrifuge at 10000 ×g for 10 min at 4°C. Keep the supernatant on ice and assay the same day.
- Dilute samples as needed using the recommended dilution factors (for example, 10% mouse liver tissue homogenate 1-10; 1×10^6 293T cells 8-25; rat plasma 1). For sample types not listed, run a pretest to confirm the dilution factor.
Assay
- Add 20 µL of each standard to standard wells, or 20 µL of sample to sample wells.
- Add 200 µL of working solution to each well.
- Mix on the microplate reader for 5 s and read OD450 (A1).
- Incubate for 10 min at 37°C and read OD450 again (A2).
- Calculate ΔA450 = A2 − A1 for each well. Use the blank-subtracted standard values to generate the standard curve.
Plasma (serum) samples: 6-PGDH activity (U/L) = (ΔA450 − b) ÷ a ÷ T × f; Tissue samples: 6-PGDH activity (U/g wet weight) = (ΔA450 − b) ÷ a × V1 ÷ m ÷ T × f × 1000; Cell samples: 6-PGDH activity (U/10^6 cells) = (ΔA450 − b) ÷ a × V2 ÷ n ÷ T × f × 1000
- Standard curve: y = ax + b, where y is the absolute ΔA (A2 minus the mean A2 of the blank, Standard #1) and x is the standard concentration (µmol/L). Create the curve with graphing software or Excel.
- ΔA450 = A2 − A1, the change in OD at 450 nm for the sample well. A1 is read immediately after mixing, and A2 is read after 10 min at 37°C.
- a = slope and b = intercept of the standard curve.
- T = reaction time, 10 min.
- f = dilution factor of the sample before testing. Multiply by f to correct for any dilution performed.
- Plasma (serum): 1 unit is the amount of 6-PGDH in 1 L of sample that catalyzes decomposition of 1 µmol of product at 37°C per min.
- Tissue: V1 = volume of tissue homogenate, 0.0009 L; m = weight of the sample, 0.1 g; 1000 converts µmol/L to nmol/L; 1 unit is the amount of 6-PGDH in 1 g of tissue that catalyzes decomposition of 1 nmol of product at 37°C per min.
- Cells: V2 = volume of cell homogenate, 0.0002 L; n = number of cells, 1 × 10^6; 1 unit is the amount of 6-PGDH in 1 × 10^6 cells that catalyzes decomposition of 1 nmol of product at 37°C per min.
- Dilution factor handling: multiply the calculated result by f, as shown in the manual's example (for example, a 5-fold dilution uses f = 5).
Which sample types can be tested with this kit?
The kit measures 6-PGDH activity in serum, plasma, animal tissue, plant tissue, and cell samples. Serum and plasma are assayed directly, while tissue and cell samples require homogenization and centrifugation first.
How should the kit components be stored, and how long are they stable?
Store the kit at -20°C, protected from light, for 12 months. Aliquoted coenzyme working solution and standard solution are stored at -20°C for 1 week, and the working solution should be prepared fresh and used on the same day.
What should I do if my sample is outside the detection range?
The detection range is 1.26-101.85 U/L. If the concentration is not within this range, take an extra dilution or concentration of the sample. Samples not listed in the manual should be pretested to confirm the dilution factor.
What factors can affect the results?
Results are closely related to reagent handling, operation, and environmental conditions. Equilibrate all reagents to 25°C before use, and always prepare a fresh set of standards.
What instrument settings are required?
Use a microplate reader with a 440-460 nm range and read absorbance at 450 nm, the optimum wavelength. The assay requires an incubator set to 37°C for the 10 min second reading.
How long does the assay take, and how much sample is needed?
The assay time is 50 min, and 20 µL of standard or sample is added per well. Each well then receives 200 µL of working solution.
| Storage: | -20°C |
| Valid period: | 12 months |
| Light sensitivity: | Protect from light |
| Working solution: | Prepare fresh and use the same day |
| Coenzyme working solution: | Aliquot and store at -20°C for up to 1 week, protected from light |
| 1000 µmol/L standard solution: | Aliquot and store at -20°C for up to 1 week, protected from light |
Notes
- For Research Use Only. Not for clinical diagnosis or therapeutic use.
- Do not mix reagents from different kits.
- Centrifuge small reagent volumes before use.
- Protect coenzyme, substrate, working solution, and standards from light.
- Prepare the working solution fresh and use it the same day.
- Prepare a fresh standard curve for every assay.
- If a sample falls outside the detection range of 1.26-101.85 U/L, dilute or concentrate it and re-assay.
- Run a pretest for sample types not listed in the dilution table.
- Cell lysates should be assayed on the day of preparation.
- Experimental results depend on reagent handling, operation, and environment. Reserve sufficient sample for repeat testing.