ACE2 Fluorometric Inhibitor Screening Kit (MAES0256)

SKU MAES0256
Product Type Assay
Instrument Fluorescence Microplate Reader
Detection Method Fluorometric
Assay Time 45 min
$884

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

ACE2 Fluorometric Inhibitor Screening Kit

The ACE2 Fluorometric Inhibitor Screening Kit (MAES0256) measures the inhibition of angiotensin-converting enzyme 2 (ACE2) activity in a microplate format. ACE2 catalyzes the cleavage of a substrate to release a fluorescent product, so a decrease in fluorescence reports inhibitor activity. Researchers use the kit to screen compounds for ACE2 inhibition and to calculate percent inhibition for test compounds.

Angiotensin-converting enzyme 2 (ACE2) is an important component of the renin angiotensin system (RAS). It acts as a negative regulatory factor of the RAS and can balance multiple functions of angiotensin-converting enzyme (ACE). By regulating angiotensin II, ACE2 cleaves angiotensin II into Ang1-7, a peptide with active effects such as protecting the heart and relaxing blood vessels. Because of this role, ACE2 is also described as one of the key active receptors in pharmaceutical science research.

Researchers use this kit to screen compounds that act as ACE2 inhibitors. The intended use is inhibitor screening, with the goal of determining how strongly a test compound suppresses ACE2 activity. The physiological context is the RAS, including the cardiac protection and vascular relaxation attributed to Ang1-7 production. Because ACE2 is a key active receptor in pharmaceutical science research, a fluorescence-based inhibition readout is useful for comparing compounds. The kit is labeled for research use only and is not intended for clinical diagnosis.

ACE2 catalyzes the decomposition of a substrate, releasing a fluorescent product. Inhibitors suppress this fluorescence, so the inhibitory ability of a compound is determined from the fluorescence value. The enzyme reagent is diluted into buffer to form an enzyme working solution, and the substrate is diluted into buffer to form a substrate working solution. After sample and reagent addition, the reaction starts immediately upon substrate addition. The plate is incubated at 37°C for 30 min and read on a fluorescence microplate reader at an excitation wavelength of 325 nm and an emission wavelength of 395 nm.

The kit is used with test compounds dissolved in DMSO. In the manual's example, quercetin, MLN-4760, rutin, and DX600 were each prepared in DMSO at concentrations of 7 to 10 mmol/L. Each well receives 5 µL of sample. The enzyme reagent must be kept on ice during use, and the reagents must be stored strictly according to their preservation conditions. Reagents from different kits must not be mixed. Prepared working solutions are stored at 2-8°C for 1 day, and the enzyme working solution is prepared on the spot before use.

Reported precision is an inter-assay CV of 10.5% and an intra-assay CV of 0.8%. In the manual's worked example, quercetin at 9.6 mmol/L gave an inhibition rate of 97.17%, calculated from a control fluorescence of 5977.31, a sample fluorescence of 347.16, and a blank fluorescence of 183.18. The inhibition curve in Appendix I was generated with the ACE2 inhibitor MLN-4760. Results depend on reagent handling, operation, and environmental conditions, so a pre-test is recommended for samples not listed in the manual.