Aconitase (ACO) Activity Assay Kit (MAES0263)

SKU MAES0263
Product Type Assay
Instrument Microplate Reader
Detection Method Colorimetric
Sample Type Animal Tissue
Sensitivity 2.32 U/L
Range 2.32-60.19 U/L
Assay Time 25 min
€648

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

Aconitase (ACO) Activity Assay Kit

The Aconitase (ACO) Activity Assay Kit (MAES0263) measures ACO enzyme activity in animal tissue homogenates by colorimetric detection of cis-aconitate at 240 nm. Aconitase is an Fe/S protein found in the cytoplasm and mitochondria that links the tricarboxylic acid and glyoxylate cycles. The kit is used to study TCA cycle and energy metabolism in tissue samples. For Research Use Only.

Aconitase (ACO) is an iron-sulfur (Fe/S) protein enzyme found mainly in the cytoplasm and mitochondria of cells. It catalyzes the reversible conversion of citric acid to isocitric acid, with cis-aconitate as the intermediate. Through this reaction, ACO helps maintain the tricarboxylic acid (TCA) cycle and the glyoxylate cycle. Because the enzyme sits at a central point in these pathways, its activity is a useful indicator of the metabolic state of the tissue under study.

Researchers measure ACO activity in animal tissue homogenates to study the TCA cycle and energy metabolism, the two research areas listed for this kit. The source materials describe assays in rat liver, mouse liver, mouse kidney, mouse brain, rat lung, mouse muscle, and mouse heart tissue, which indicates use across several organ systems. The product page also lists related kits used together with this product in published studies: α-ketoglutarate dehydrogenase, citrate synthase, pyruvate dehydrogenase, and NAD-isocitrate dehydrogenase. Measuring these activities in parallel allows comparison across the cycle.

The assay measures the rate of cis-aconitate formation from isocitrate. Cis-aconitate has a characteristic absorption peak at 240 nm, so its production is followed by reading optical density (OD) at that wavelength on a microplate reader set to 230–250 nm, with 240 nm as the optimum. Sample supernatant is combined with substrate at a volume ratio of 80:1 and incubated at 37 °C for 10 min. Each well then receives 20 µL of sample and 180 µL of buffer solution. After the first OD reading (A1), the plate is incubated at 25 °C for 4 min and read again (A2). The change, ΔA = A2 − A1, is used for calculation.

The kit is intended for animal tissue samples. Tissue is homogenized in extraction solution A with protease inhibitor at 4 °C, and the resulting fractions are used to determine cytoplasmic and mitochondrial ACO activity separately, each with its own protein measurement. Fresh samples are recommended because the enzyme is easily inactivated. Processed samples should be kept on ice and used within 2 hours. The substrate is prone to oxidation and should be covered promptly after each use. All reagents should be equilibrated to room temperature before use, and components from different kits should not be mixed.

Analytical sensitivity is 2.32 U/L, determined by adding two standard deviations to the mean OD of the zero standard assayed 20 times and calculating the corresponding concentration. The detection range is 2.32–60.19 U/L. In the manual's performance appendix, intra-assay precision for three mouse liver samples (20 replicates each) gave CV values of 9.1–10.0%, and inter-assay CVs were 5.3–6.8%. Average recovery across high, middle, and low concentration samples was 103%, with individual recoveries of 98–107%. The product page lists summary values of 5.9% intra-assay CV and 9.5% inter-assay CV.