Description
Annexin V-EGFP Reagent
Annexin V-EGFP Reagent (AKES013) is an EGFP-conjugated Annexin V probe for identifying apoptotic cells. Annexin V binds phosphatidylserine (PS) in a calcium-dependent manner and binds specifically to PS exposed on the outer leaflet of the apoptotic cell membrane. Detection is by flow cytometry or fluorescence microscopy, and the probe can be combined with a membrane-impermeant DNA dye to distinguish apoptotic stages. For Research Use Only.
Annexin V is a member of the annexin family of proteins that binds phosphatidylserine (PS) in a calcium-dependent manner. Annexin V-EGFP Reagent is an EGFP-conjugated form of Annexin V developed to identify apoptotic cells. The conjugate binds specifically to PS on the outer leaflet of the apoptotic cell membrane, so the reagent reports membrane changes that accompany apoptosis rather than a soluble analyte.
Researchers use Annexin V-EGFP Reagent to identify apoptotic cells and to distinguish apoptotic stages within a population. Cells at different stages can be separated by combining Annexin V with a membrane-impermeable DNA dye such as propidium iodide (PI), 7-aminoactinomycin D (7-AAD), or DAPI. In the source example, Jurkat cells treated with 5 µM camptothecin for 4 h showed Annexin V-EGFP single-positive early apoptotic cells, while Annexin V-EGFP and PI double-positive cells were necrotic or late apoptotic, and PI single-positive cells were naked nuclei.
The assay is a fluorescence labeling method. Cells are resuspended in 1× Annexin V Binding Buffer, which provides the calcium required for PS binding, and then stained with Annexin V-EGFP Reagent and, optionally, a DNA dye. The mixture is gently vortexed and incubated at room temperature for 15 to 20 min in the dark. Labeled cells are read by flow cytometry using the FITC channel, with excitation and emission at 488 and 510 nm, or by fluorescence microscopy.
The reagent is intended for cell samples, including suspension cells and adherent cells. For adherent cultures, suspension cells generated during apoptosis induction must be collected and analyzed together with the adherent cells harvested afterward. Mechanical damage during digestion should be minimized, and trypsin solutions should avoid EDTA, which interferes with Annexin V binding to PS. Stained samples should be analyzed promptly, and extended exposure to direct light should be avoided to protect the fluorophore from quenching.
| Name: | Annexin V-EGFP Reagent |
| SKU: | AKES013 |
| Pack Size: | 50 Tests, 200 Tests |
| Application: | Annexin V detection of apoptotic cells |
| Detection method: | Fluorometric; flow cytometry |
| Sample type: | Cell samples (suspension cells; adherent cells after harvest) |
| Assay time: | 40 min |
| Detection instrument: | Flow cytometer; fluorescence microscope |
| Dye type: | EGFP |
| Excitation/Emission: | 488/510 nm |
| Channel set: | FITC |
| Other reagents required: | Annexin V Binding Buffer, PBS, deionized water |
- Annexin V conjugated to EGFP (Ex/Em 488/510 nm; FITC channel)
- Binds exposed phosphatidylserine in a calcium-dependent manner
- Compatible with flow cytometry and fluorescence microscopy
- Staining protocol of about 40 min, including a 15 to 20 min room-temperature incubation
- Can be combined with PI, 7-AAD, or DAPI to separate early apoptotic, necrotic, and late apoptotic cells
Annexin V binds phosphatidylserine (PS) in a calcium-dependent manner. Annexin V-EGFP binds specifically to PS on the outer leaflet of apoptotic cell membranes. Bound probe is detected by EGFP fluorescence (Ex/Em 488/510 nm, FITC channel) using flow cytometry or fluorescence microscopy.
- Detection of early apoptotic cells by PS exposure using flow cytometry
- Fluorescence microscopy of Annexin V-positive cells
- Discrimination of early apoptotic, necrotic, and late apoptotic cells when combined with PI, 7-AAD, or DAPI
- Apoptosis assays on suspension cells, and on adherent cells after harvest
| Component | Quantity | Storage |
| Annexin V-EGFP Reagent | 50 Tests: 125 µL × 2; 200 Tests: 500 µL × 2 | 2-8 °C, protect from light; avoid freeze/thaw cycles |
- Annexin V Binding Buffer (1×), user-supplied
- Phosphate-buffered saline (PBS)
- Deionized water
- DNA dye for co-staining: PI, 7-AAD, or DAPI (user-supplied, optional)
- Flow cytometer with 488 nm excitation and FITC channel detection, or fluorescence microscope
- Centrifuge capable of 300 ×g
- Microcentrifuge tubes, vortex mixer, and ice
- Trypsin without EDTA for adherent cell harvest (if applicable)
Cells (suspension and adherent)
- Induce apoptosis in suspension cells with the reagents of interest. Collect the cell culture, centrifuge at 300 × g for 5 min, and discard the supernatant. Wash the cells with PBS, resuspend gently, and count the cells.
- For adherent cells, collect the suspension cells generated after apoptosis induction and analyze them together with the adherent cells harvested subsequently. Avoid mechanical damage during digestion as much as possible.
- If trypsin containing EDTA is used, wash the cells thoroughly after harvesting to ensure EDTA is removed.
- Divide the cell suspension into tubes at 1 to 5 × 10^5 cells per tube. Centrifuge at 300 × g for 5 min, discard the supernatant, and wash the cells with PBS. Discard the supernatant again.
- Prepare 1× Annexin V Binding Buffer from the 10× concentrate. Add 500 µL of 1× Annexin V Binding Buffer to each tube and resuspend the cells.
- Add 5 µL of Annexin V-EGFP Reagent and 5 µL of the DNA dye (PI, 7-AAD, or DAPI) to each tube.
- Gently vortex the cells and incubate at room temperature for 15 to 20 min in the dark.
- Analyze the cells immediately with appropriate instrument settings. Otherwise, place the cells on ice in the dark and analyze within 1 h.
Cell preparation and staining
- Induce apoptosis in cells with the reagent of interest. For suspension cells, collect the culture and centrifuge at 300 ×g for 5 min. Discard the supernatant.
- For adherent cells, collect the suspension cells generated during induction together with the subsequently harvested adherent cells.
- Wash cells with PBS, resuspend gently, and count.
- Aliquot 1 to 5 ×105 cells per tube. Centrifuge at 300 ×g for 5 min, discard the supernatant, wash with PBS, and discard the supernatant again.
- Resuspend cells in 500 µL of 1× Annexin V Binding Buffer.
- Add 5 µL of Annexin V-EGFP Reagent and 5 µL of DNA dye (PI, 7-AAD, or DAPI) to each tube, if co-staining.
- Gently vortex and incubate at room temperature for 15 to 20 min in the dark.
- Analyze immediately. Alternatively, place cells on ice in the dark and analyze within 1 h.
What sample types are compatible with Annexin V-EGFP Reagent?
The reagent is designed for cell samples, including suspension cells and adherent cells. For adherent cells, collect the suspension cells produced during apoptosis induction and analyze them together with the harvested adherent cells.
How should the reagent be stored?
Store at 2 to 8°C in the dark (shading light) and avoid freeze/thaw cycles. The product page lists a shelf life of 12 months.
What instrument settings should be used?
Use a flow cytometer with the FITC channel (excitation/emission 488/510 nm) or a fluorescence microscope. Set machine parameters appropriately for the EGFP signal and any DNA dye used.
What can interfere with staining?
EDTA in trypsin digestion solutions affects Annexin V binding to phosphatidylserine. If EDTA-containing trypsin is used, wash the cells thoroughly after harvesting to remove it.
How long does the assay take, and how soon should samples be analyzed?
The assay time is 40 min, including a 15 to 20 min incubation at room temperature in the dark. Analyze cells immediately after staining, or place them on ice in the dark and analyze within 1 h.
How do I interpret the staining patterns?
Annexin V-EGFP single-positive cells are early apoptotic cells. Annexin V-EGFP and PI double-positive cells are necrotic or late apoptotic cells, and PI single-positive cells are naked nuclei.
| Storage: | 2-8 °C, protect from light (shading light) |
| Storage duration: | One year (12 months) in the dark |
| Freeze/thaw: | Avoid freeze/thaw cycles |
| Shipping: | Ice bag |
| Expiration: | 12 months |
Cautions
- For Research Use Only. Not for diagnostic or therapeutic use.
- Detect apoptosis as soon as possible after staining to avoid an increase in apoptotic or necrotic cells.
- Avoid extended exposure of samples to direct light to protect the fluorophore from quenching.
- Trypsin digestion solution should not contain EDTA where possible, because EDTA interferes with Annexin V binding to phosphatidylserine. If EDTA-containing trypsin is used, wash cells thoroughly after harvest.
- Avoid mechanical damage during digestion of adherent cells.
- Wear a lab coat and disposable gloves during experiments.