Description
BSA Removal Kit
The BSA Removal Kit (AKES153) is a research reagent for removing bovine serum albumin (BSA) from antibody preparations before chemical labeling. BSA co-purified with an antibody can greatly reduce labeling efficiency, and this kit separates the antibody from BSA by precipitation in about 15 minutes. The purified antibody can be used directly for subsequent labeling of reduced antibodies without a replacement buffer step.
Bovine serum albumin (BSA) is often added to antibody solutions as an antibody protectant. When an antibody must be chemically labeled, the BSA present in the preparation has to be removed first. If it is not removed, the labeling coupling efficiency is greatly reduced. The problem is most severe when BSA is present at a higher concentration than the antibody, because successful labeling is then almost impossible. This kit separates the antibody from its carrier protein before conjugation.
Researchers use this kit as a preparation step before labeling antibodies with small-molecule dyes, including NHS-ester dyes. Common alternatives for BSA removal include protein A/G or antigen affinity purification, molecular exclusion purification, and other purification methods. The source describes these as cumbersome and costly in both conditions and reagents. This kit provides a shorter workflow of about 15 minutes, and the purified antibody can proceed directly to labeling of reduced antibody without buffer replacement.
The procedure is a precipitation-based separation. The antibody mixture is combined with BSA removal buffer at 80 µL per 100 µL of mixture, incubated at room temperature for 5 minutes, and centrifuged at 13000×g for 5 minutes. The supernatant containing BSA is discarded, leaving a white precipitate of purified antibody at the bottom of the tube. The pellet is then dissolved in 1× PBS (pH 7.4) or another buffer suited to the downstream labeling chemistry. The kit contains no detection chemistry, so there is no wavelength or absorbance readout. Typical results compare the BSA-only supernatant with the redissolved purified antibody pellet. Quantification of the purified antibody should be done by PAGE electrophoresis, because A280 and BCA measurements are not accurate while BSA is present in the pre-purified sample.
The kit is described as suitable for each antibody subtype of each species, but the cautions state that only IgG antibodies were tested. IgM, IgA, IgD, IgE, IgY, other recombinant subtype antibodies, and antibody fragments were not tested, and purification efficiency may differ for these types. Antibodies containing gelatin or other non-BSA proteins may not yield a visible pellet. Antibody pH should be within 6.0 to 8.0, and glycerol above 20% interferes with purification. The kit should be stored at 2 to 8 °C, where an unopened kit is stable for 12 months. BSA removal buffer may crystallize, and it should be fully dissolved in a 37 °C water bath and equilibrated to room temperature before use.
| Product name: | BSA Removal Kit |
| SKU: | AKES153 |
| Application: | Antibody labeling (BSA removal prior to labeling) |
| Intended use: | Research use only |
| Processing time: | About 15 min |
- Removes BSA from antibody samples in about 15 min
- Precipitation-based workflow; purified antibody needs no replacement buffer
- Direct use of purified antibody for subsequent labeling steps
- Optional 50 kDa ultrafiltration pre-treatment for pH or glycerol adjustment
- Suitable for IgG antibodies; tested on IgG only
The kit uses precipitation to separate antibody from BSA. The BSA-containing antibody sample is mixed with BSA Removal buffer at 80 µL per 100 µL of sample, incubated at room temperature for 5 min, and centrifuged at 13000×g for 5 min. The BSA-containing supernatant is discarded, and the white precipitate at the bottom of the tube is the purified antibody.
- Pre-labeling purification of antibodies to remove BSA before conjugation
- Preparation of BSA-free IgG for labeling with reduced antibodies
- Preparation of BSA-free IgG for labeling with NHS-ester dyes, following desalting
- Antibody workflows where BSA is present as an antibody protectant
| Component | Storage |
| BSA Removal buffer | 2 to 8°C |
| 1× PBS (pH 7.4) | 2 to 8°C |
- High precision pipette
- Centrifuge capable of 13000×g
- Thermostatic water bath set to 37 °C
- Disposable suction tips
- 1.5 mL microcentrifuge tubes
- 50 kDa ultrafiltration tube (optional, for pH or glycerol pre-treatment)
Antibody (IgG) solution containing BSA
- Equilibrate all kit components to room temperature. If the BSA removal buffer has crystallized, dissolve it completely in a 37 °C water bath, then equilibrate to room temperature.
- Perform optional ultrafiltration if the antibody pH is outside 6.0 to 8.0 or the glycerol concentration exceeds 20%. Add 450 µL of 1× PBS (pH 7.4) to a 50 kDa ultrafiltration tube, centrifuge at 13000×g for 1 minute, and discard the collection tube liquid. Add the antibody to the inner tube and bring the volume to 450 µL. Centrifuge at 13000×g for 1 minute. Repeat the ultrafiltration three times. Invert the inner tube into a clean collection tube, centrifuge at 13000×g for 1 minute, and collect the liquid in the inner tube.
- If the BSA concentration is above 0.5%, dilute the antibody to below 0.5% BSA.
- If the purified antibody amount is below 60 µg, concentrate the antibody by ultrafiltration before proceeding. Otherwise, no visible white pellet may form after centrifugation.
- Add 80 µL of BSA removal buffer per 100 µL of antibody mixture to a 1.5 mL tube. Mix, incubate at room temperature for 5 minutes, and centrifuge at 13000×g for 5 minutes.
- Discard the supernatant, removing as much liquid as possible without disturbing the pellet. The white precipitate at the bottom is the purified antibody. Residual liquid can cause labeling failure with NHS-containing dyes.
- Dissolve the purified antibody in 1× PBS (pH 7.4). Estimate the buffer volume from the original antibody amount and the required concentration, or use another buffer suited to the application. For dye labels containing NHS groups, desalt the antibody by dialysis or ultrafiltration before labeling. If only reduction treatment is performed, this step is not required.
Preparation
- Remove the kit components and equilibrate to room temperature.
- If BSA Removal buffer has crystallized, dissolve it completely in a 37 °C water bath, then equilibrate to room temperature before use.
Optional pre-treatment (pH outside 6.0 to 8.0 or glycerol above 20%)
- Add 450 µL 1× PBS (pH 7.4) to a 50 kDa ultrafiltration tube and centrifuge at 13000×g for 1 min. Discard the collection tube liquid.
- Add the antibody sample to the inner tube and bring the volume to 450 µL with 1× PBS (pH 7.4).
- Centrifuge at 13000×g for 1 min. Repeat the ultrafiltration three times.
- Invert the inner tube into a clean collection tube and centrifuge at 13000×g for 1 min. Collect the liquid in the inner tube.
BSA removal
- Transfer the antibody mixture to a 1.5 mL tube. Add BSA Removal buffer at 80 µL per 100 µL of mixture and mix.
- Incubate at room temperature for 5 min, then centrifuge at 13000×g for 5 min.
- Centrifuge and discard the supernatant. The white precipitate at the bottom is the purified antibody.
- Remove as much supernatant as possible without disturbing the pellet.
- Dissolve the purified antibody in 1× PBS (pH 7.4), estimating the volume from the original antibody amount and the required concentration, then proceed directly to labeling or dissolve in another buffer as needed.
Which antibody types work with this kit?
The kit is intended for IgG antibodies, and only IgG was tested. IgM, IgA, IgD, IgE, IgY, recombinant subtype antibodies, and antibody fragments were not tested and may purify differently. Nanobodies and antibody fragments are listed as unsuitable in the troubleshooting section.
How should the kit be stored?
Store the kit at 2 to 8 °C. An unopened kit is stable for 12 months. BSA removal buffer may crystallize, so dissolve it completely in a 37 °C water bath and equilibrate to room temperature before use.
What should I do if no white pellet forms?
Check the antibody amount, which must be above 60 µg. If the concentration is low, concentrate the antibody by ultrafiltration first. Also confirm that the BSA removal buffer was added at 80 µL per 100 µL of mixture and that the supernatant was removed without disturbing the pellet.
What sample conditions interfere with purification?
Antibody pH must be between 6.0 and 8.0. Glycerol above 20% interferes, and BSA above 0.5% requires dilution. Antibodies containing gelatin or other non-BSA proteins may not yield a pellet, and antibody affinity chromatography is recommended for these.
What centrifuge settings and labware are needed?
Centrifuge at up to 13000×g, using 1.5 mL tubes for the precipitation step and a 50 kDa ultrafiltration tube for optional pre-treatment. Perform the steps at room temperature.
How long does the procedure take?
The whole process requires about 15 minutes. The precipitation step itself is 5 minutes of incubation at room temperature followed by 5 minutes of centrifugation.
| Storage temperature: | 2 to 8°C |
| Shelf life: | 12 months (unopened kit) |
| Shipping: | Ice bag |
Cautions
- For research use only. Not for diagnostic or therapeutic use.
- Use at least 60 µg of purified antibody. Lower amounts may not produce a visible white precipitate after centrifugation; concentrate low-concentration antibody by ultrafiltration first.
- If BSA concentration is above 0.5%, dilute the antibody to below 0.5% BSA before use.
- If the antibody pH is outside 6.0 to 8.0, or glycerol exceeds 20%, perform the optional ultrafiltration pre-treatment.
- Dyes containing NHS groups require dialysis or ultrafiltration desalination of the purified antibody before labeling. Reduction-only workflows do not require this step.
- This kit has been tested with IgG antibodies only. Performance with IgM, IgA, IgD, IgE, IgY, recombinant subtypes, nanobodies, or antibody fragments has not been tested, and purification efficiency may differ.
- Antibodies containing proteins other than BSA, such as gelatin, may not be purified effectively.
- Wear a lab coat and disposable gloves.