Description
Calcein AM Assay Buffer
Calcein AM Assay Buffer (AKES091) is an isotonic loading buffer designed for Calcein AM probe staining of suspended and adherent cells. It is formulated to improve Calcein AM loading efficiency and to reduce Calcein leakage from anionic cells and P-glycoprotein carrier cells. The buffer is compatible with propidium iodide (PI) co-staining for distinguishing dead cells. Research Use Only.
Calcein AM Assay Buffer is a buffer formulated for loading the Calcein AM probe, which yields green fluorescent calcein in stained cells. The buffer is built on a cell isotonic buffer base and is designed to be compatible with propidium iodide (PI) staining working solution. According to the manual, it increases the efficiency of Calcein AM loading and reduces calcein leakage from anionic cells and P-glycoprotein carrier cells, which supports the best staining efficiency.
Researchers use this buffer to stain cells with Calcein AM and, when co-stained with PI, to distinguish dead cells. Staining can be read directly by flow cytometry or fluorescence microscopy, which suits workflows that assess individual cells or fields. The source material does not name specific disease models or physiological contexts. Its stated applications are staining of suspended cells and adherent cells, including anionic cells and P-glycoprotein carrier cells, where calcein leakage is reduced.
Calcein AM staining is performed by incubating cells with a working solution prepared from Calcein AM Solution (100 µM) and this buffer. Suspended cells are resuspended in 200 µL of working solution per group of 1 to 5×10⁵ cells and incubated for 5 to 15 min at room temperature in the dark. Adherent cells receive 100 µL per well in a 96-well plate or 200 µL per well in a 24-well plate and are incubated at 37°C for 10 to 30 min. Calcein is green fluorescent, with Ex/Em of 494/517 nm. PI is red fluorescent, with Ex/Em of 535/617 nm.
Suitable samples are suspended cells and adherent cells. Before staining, wash cells with serum-free medium or PBS, because serum may contain esterase. The buffer should not contain primary or secondary amines, which can hinder loading. Suspended cells are centrifuged at 300×g for 5 min and the supernatant is discarded, while adherent cells are washed with PBS and the PBS is removed. Centrifuge acceleration should be no more than 3 and deceleration no more than 2 to avoid cell loss. Store the buffer at -20°C.
| Product name: | Calcein AM Assay Buffer |
| SKU: | AKES091 |
| Intended use: | Loading of Calcein AM probe for live-cell staining |
| Compatible co-stain: | Propidium iodide (PI) staining working solution |
| Readout: | Flow cytometry or fluorescence microscopy |
| Use: | Research Use Only |
- Designed specifically for loading Calcein AM probe
- Based on cell isotonic buffer
- Reduces Calcein leakage in anionic cells and P-glycoprotein carrier cells
- Compatible with PI staining working solution
- Suitable for flow cytometry and fluorescence microscopy readout
Cells are incubated with Calcein AM staining working solution prepared in Calcein AM Assay Buffer. Intracellular esterases convert Calcein AM to green fluorescent Calcein (Ex/Em = 494 nm/517 nm). Co-staining with PI solution (Ex/Em = 535 nm/617 nm) labels dead cells with red fluorescence. For flow cytometry, Calcein is detected in the FITC channel and PI in the PE or PerCP/Cy5.5 channel.
- Live-cell viability staining of suspended cells by flow cytometry
- Calcein AM staining of adherent cells in 96-well or 24-well plates for fluorescence microscopy
- Co-staining with PI to distinguish live and dead cells
- Calcein AM loading in anionic cells and P-glycoprotein carrier cells where Calcein leakage is a concern
- Calcein AM stock solution (100 µM)
- Propidium iodide (PI) solution (750 µM), optional for dead-cell co-staining
- Phosphate-buffered saline (PBS)
- Serum-free medium
- Centrifuge
- Flow cytometer or fluorescence microscope
- 96-well or 24-well plates for adherent cells
- Incubator at 37°C and dark incubation at room temperature
Suspended cells
- Collect the cells and centrifuge at 300×g for 5 min. Discard the supernatant.
- Add 1 mL of PBS to resuspend the cells. Centrifuge at 300×g for 5 min and discard the supernatant.
- Repeat the wash one time and discard the supernatant.
- Prepare an appropriate amount of Calcein AM staining working solution using Calcein AM Solution (100 µM) and Calcein AM Assay Buffer.
- Add 200 µL of Calcein AM staining working solution to resuspend 1 to 5×10⁵ cells in each group. Incubate for 5 to 15 min at room temperature in the dark.
- After incubation, detect the staining directly by flow cytometry or observe under a fluorescence microscope.
Adherent cells
- Carefully remove the culture medium.
- Add an appropriate amount of PBS to each well to wash the cells. Repeat the wash on the slides and remove the PBS.
- Prepare an appropriate amount of Calcein AM staining working solution using Calcein AM Solution (100 µM) and Calcein AM Assay Buffer.
- Add Calcein AM staining working solution at 100 µL per well in a 96-well plate or 200 µL per well in a 24-well plate. Incubate at 37°C for 10 to 30 min.
- After incubation, detect the staining directly by flow cytometry or observe under a fluorescence microscope.
Sample preparation
- Suspended cells: Collect cells, centrifuge at 300×g for 5 min, and discard the supernatant. Resuspend the cells in 1 mL PBS, centrifuge at 300×g for 5 min, and discard the supernatant.
- Adherent cells: Remove the culture medium, add an appropriate volume of PBS to each well to wash, and remove the PBS.
Staining
- Prepare the Calcein AM staining working solution by diluting Calcein AM solution (100 µM) in Calcein AM Assay Buffer.
- Suspended cells: Add 200 µL of Calcein AM staining working solution to resuspend 1–5×105 cells per group. Incubate for 5–15 min at room temperature in the dark.
- Adherent cells: Add Calcein AM staining working solution at 100 µL per well in a 96-well plate or 200 µL per well in a 24-well plate. Incubate at 37°C for 10–30 min.
Detection
- Detect staining directly by flow cytometry or observe under a fluorescence microscope.
- Optional: co-stain with PI solution (750 µM) to distinguish dead cells.
How should the buffer be stored?
Store Calcein AM Assay Buffer at -20°C. The stated shelf life is 12 months.
What sample types can be stained with this buffer?
The buffer is used for suspended cells and adherent cells. Before staining, wash cells with serum-free medium or PBS, because serum may contain esterase.
Which components or conditions can interfere with loading?
The buffer should not contain primary or secondary amines, which can hinder loading. Serum may contain esterase, so cells should be washed in serum-free medium or PBS before staining.
Which instrument channels and wavelengths should be used?
For flow cytometry, detect Calcein in the FITC channel and PI in the PE or PerCP/Cy5.5 channel. Calcein is green fluorescent with Ex/Em of 494/517 nm, and PI is red fluorescent with Ex/Em of 535/617 nm.
How long does staining take?
Suspended cells are incubated for 5 to 15 min at room temperature in the dark. Adherent cells are incubated at 37°C for 10 to 30 min.
What centrifuge settings should be used to avoid cell loss?
Excessive acceleration and deceleration can cause cell loss. Set acceleration to no more than 3 and deceleration to no more than 2.
| Storage temperature: | -20°C |
| Shelf life: | 12 months |
| Shipping: | Ice bag |
Cautions
- For Research Use Only. Not for diagnostic or therapeutic use.
- Wash cells with serum-free medium or PBS before staining, because serum may contain esterases.
- Do not use buffers containing primary or secondary amines, which can hinder AM ester loading.
- Store the product at -20°C to avoid loss of performance.
- Limit centrifuge acceleration to no more than 3 and deceleration to no more than 2 (Acc≤3, Dec≤2) to reduce cell loss.
- Follow standard laboratory reagent safety procedures.