Description
Citrate Synthase (CS) Activity Assay Kit
The Citrate Synthase (CS) Activity Assay Kit (MAES0239) measures CS enzyme activity in animal tissue, plant tissue, and cell samples. The assay is colorimetric: CS-dependent formation of the yellow product is followed by the change in absorbance at 412 nm. Researchers use it to quantify CS activity in tricarboxylic acid (TCA) cycle and mitochondrial energy metabolism studies.
Citrate synthase (CS) is a mitochondrial enzyme of the tricarboxylic acid (TCA) cycle. It catalyzes the reaction of acetyl-CoA with oxaloacetate to produce limonyl-CoA, which can further produce CoA. Because this step links acetyl-CoA entry to the cycle, CS sits at a central point in cellular energy metabolism. The Assay Genie Citrate Synthase (CS) Activity Assay Kit (MAES0239) measures this enzymatic activity in tissue and cell samples.
Researchers measure CS activity to study mitochondrial function, TCA cycle flux, and energy metabolism. The kit's stated research areas are mitochondria function, the TCA cycle, and energy metabolism. The supplied sources describe use with animal tissue, plant tissue, and cell samples, and they report measurements in rat and mouse tissue homogenates. They do not name specific disease models, so any disease-related application must be defined by the investigator.
The assay is colorimetric. CS activity produces a yellow product with a characteristic absorption peak at 412 nm, and activity is calculated from the change in absorbance at that wavelength. The kit contains buffer, substrate, chromogenic agent, and standard reagents. After a 3-minute 37 °C incubation, the first absorbance reading (A1) is taken. Following an 8-minute 37 °C incubation, the second reading (A2) is taken, and ΔA is calculated as A2 minus A1. Readings are made on a microplate reader at 402–422 nm, with 412 nm as the optimum wavelength.
Suitable samples include animal tissue, plant tissue, and cells. Tissue is homogenized at 4 °C and centrifuged to remove insoluble material, and the supernatant is kept on ice. Cells are washed in PBS, disrupted at 4 °C, and centrifuged, and the supernatant is kept on ice. Reagents must be stored at -20 °C for up to 12 months, with the chromogenic agent and standard protected from light. The chromogenic agent may stay on ice for no more than 2 hours after thawing and must be returned to -20 °C immediately after use. The 10 mmol/L standard solution may be stored at -20 °C for 3 days, and repeated freeze-thaw cycles should be avoided. The 1 mmol/L standard must be prepared fresh and used within 2 hours.
Reported performance figures include an analytical sensitivity of 2.09 U/L and a detection range of 2.09–110 U/L. Intra-assay precision was 3.9–5.6% CV, and inter-assay precision was 6.4–9.8% CV, based on mouse liver tissue samples. Spike recovery across three standard concentrations ranged from 98% to 108%, with an average recovery of 104%.
| Product Name: | Citrate Synthase (CS) Activity Assay Kit |
| SKU: | MAES0239 |
| Assay Type: | Enzyme activity |
| Synonyms: | CS |
| Sample Type: | Animal tissue, plant tissue, and cells |
| Detection Method: | Colorimetric |
| Detection Instrument: | Microplate reader (402–422 nm; optimum wavelength 412 nm) |
| Assay Time: | 30 min |
| Sensitivity: | 2.09 U/L |
| Detection Range: | 2.09–110 U/L |
| Intra-assay CV: | 5% |
| Inter-assay CV: | 7.9% |
| Sample Volume: | 10 µL tissue homogenate |
| Other Instruments Required: | Incubator, centrifuge |
- Colorimetric CS activity measurement read at 412 nm (microplate reader, 402–422 nm range)
- Detection range 2.09–110 U/L; analytical sensitivity 2.09 U/L
- Assay time of 30 min
- Validated for animal tissue, plant tissue, and cell samples
- Intra-assay CV 5%; inter-assay CV 7.9%
- Research Use Only
Citrate synthetase (CS) catalyzes acetyl-CoA and oxaloacetate to produce limonyl-CoA, which can further produce CoA. The yellow product generated by this reaction has a characteristic absorption peak at 412 nm. The activity of CS is calculated by measuring the change in absorbance at 412 nm between two read points (A1 and A2) separated by an 8 min incubation at 37 °C.
- Measuring CS activity in animal tissue homogenates for mitochondrial and TCA cycle studies
- Comparing CS activity across tissues, such as mouse liver, kidney, heart, and lung homogenates
- Assessing CS activity in plant tissue extracts
- Quantifying CS activity in cell lysates for energy metabolism research
| Component | Quantity | Storage |
| Reagent 1: Extraction Solution | Included | -20°C, 12 months |
| Reagent 2: Buffer Solution | Included | -20°C, 12 months |
| Reagent 3: Substrate | Included | -20°C, 12 months; protect from light |
| Reagent 4: Chromogenic Agent | Included | -20°C, 12 months; protect from light |
| Reagent 5: Standard Powder | Included | -20°C, 12 months; protect from light |
| Microplate (wells) | Included | No requirement |
- Microplate reader capable of 402–422 nm reading (optimum 412 nm)
- Incubator set to 37 °C
- Centrifuge capable of 10000 × g
- Dounce homogenizer (tissue) or ultrasonic cell disruptor (cells)
- Ice bath
- PBS (0.01 M, pH 7.4) for washing cells
- Double-distilled water for standard preparation
- Protein concentration assay for determining sample protein (required for U/g protein calculation)
- Precision pipettes and microplate-compatible tubes
Tissue
- Harvest the amount of tissue needed for each assay. The initial recommendation is 20 mg.
- Homogenize 20 mg of tissue in 180 µL of extraction solution with a Dounce homogenizer at 4 °C.
- Centrifuge at 10000×g for 15 minutes to remove insoluble material.
- Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant using a separate protein quantification assay. This value is required for the calculation.
- Dilution: the recommended dilution factor is 1 for 10% rat kidney, spleen, liver, and heart tissue homogenates, and for 10% mouse liver and lung tissue homogenates. The diluent is extraction solution. For other sample types, perform a pretest to confirm the dilution factor.
Cells
- Harvest the number of cells needed for each assay. The initial recommendation is 1×10^6 cells.
- Wash cells with PBS (0.01 M, pH 7.4).
- Homogenize 1×10^6 cells in 200 µL of extraction solution with an ultrasonic cell disruptor at 4 °C.
- Centrifuge at 10000×g for 10 minutes to remove insoluble material.
- Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant using a separate protein quantification assay. This value is required for the calculation.
- Dilution: the recommended dilution factor is 1 for the listed tissue homogenates. The diluent is extraction solution. For other sample types, perform a pretest to confirm the dilution factor.
Reagent preparation
- Equilibrate all reagents to room temperature before use.
- After melting, keep the chromogenic agent on ice for no more than 2 h, then return it to -20 °C immediately after use.
- Prepare the 10 mmol/L standard stock by dissolving one vial of standard powder in 1 mL double-distilled water. Aliquot and store at -20 °C for up to 3 days, protected from light; avoid repeated freeze/thaw cycles.
- Prepare 1 mmol/L standard fresh by mixing 100 µL of 10 mmol/L standard with 900 µL double-distilled water. Use within 2 h.
- Prepare the standard curve fresh for each assay by diluting 1 mmol/L standard with double-distilled water: 0, 40/160, 60/140, 80/120, 120/80, 160/40, 180/20, and 200/0 µL of 1 mmol/L standard/water (final concentrations 0, 0.2, 0.3, 0.4, 0.6, 0.8, 0.9, and 1 mmol/L). Discard working standards after use.
Sample preparation
- Tissue: homogenize 20 mg tissue in 180 µL extracting solution at 4 °C with a dounce homogenizer. Centrifuge at 10000 × g for 15 min. Keep the supernatant on ice.
- Cells: wash 1 × 106 cells with PBS (0.01 M, pH 7.4). Homogenize in 200 µL extracting solution at 4 °C with an ultrasonic cell disruptor. Centrifuge at 10000 × g for 10 min. Keep the supernatant on ice.
- Determine the protein concentration of each supernatant using a separate protein assay.
- Dilute samples as needed. For the listed tissue homogenates (10%), the recommended dilution factor is 1. For other sample types, perform a pretest to confirm the dilution factor.
CS activity (U/gprot) = (ΔA412 - b) ÷ a ÷ T × 1000 ÷ Cpr × f
- ΔA412 is the change in OD value of the sample well (A2 minus A1 at 412 nm).
- a and b are the slope and intercept of the standard curve, y = ax + b. Standard curve values are based on absolute OD, which is the mean standard OD minus the mean blank OD.
- T is the incubation time of the reaction, 8 min.
- 1000 converts units: 1 mmol/L = 1000 µmol/L.
- Cpr is the protein concentration of the sample, in gprot/L.
- f is the dilution factor of the sample before testing. Use 1 if the sample is not diluted.
- One unit is defined as the amount of CS in 1 g of tissue or cell protein that produces 1 µmol of CoA per minute at 37 °C.
- Example from the manual: (0.871 – 0.695 + 0.0099) ÷ 0.3699 ÷ 8 × 1000 ÷ 7.40 = 8.49 U/gprot for 10% mouse liver tissue homogenate.
What sample types can be used with this kit?
The kit measures CS activity in animal tissue, plant tissue, and cell samples. For sample types not listed in the manual, perform a pretest to confirm the dilution factor.
How should samples and reagents be stored?
Store the reagents at -20 °C for 12 months, with the chromogenic agent and standard protected from light. Keep prepared samples on ice until use. Avoid repeated freeze-thaw cycles for the 10 mmol/L standard solution.
What should I do if my sample is outside the detection range?
The detection range is 2.09–110 U/L. The manual advises an extra dilution or concentration if the substance is not within the detection range. Confirm the dilution factor with a pretest for any sample type not listed.
What are the key points for a successful assay?
Avoid bubbles when adding reagents. Thaw the chromogenic agent on ice and use it within 2 hours, then return it to -20 °C immediately. Prepare the 1 mmol/L standard fresh and use it within 2 hours. Perform the assay according to the operating steps and read the absorbance at 412 nm.
What instrument settings are required?
Use a microplate reader with a 402–422 nm filter range. The optimum wavelength is 412 nm. Read absorbance at 412 nm at the initial reading (A1) and after the 8-minute incubation (A2).
How long does the assay take?
The assay time is 30 minutes. The procedure includes a 3-minute incubation at 37 °C, a first reading, an 8-minute incubation at 37 °C, and a second reading.
| Storage: | -20°C; protect light-sensitive components from light |
| Shelf Life: | 12 months |
Notes
- For research use only. Not for clinical diagnosis.
- Put the chromogenic agent on ice for no more than 2 h after melting, then return it to -20°C immediately after use.
- Store the 10 mmol/L standard solution at -20°C for up to 3 days, protected from light, and avoid repeated freeze/thaw cycles.
- Prepare the 1 mmol/L standard solution fresh and use it within 2 h.
- Avoid bubbles when adding reagents.
- Do not mix reagents from different kits.