Description
Cyanine7 Labeling Kit
The Cyanine7 Labeling Kit (AKES134) provides the reagents for covalent labeling of antibodies and other proteins that carry primary amino groups. The Cyanine7 NHS ester reacts with N-terminal and lysine side-chain amines to form a stable amide bond. The kit includes a 10 kDa filtration device for buffer exchange and removal of unreacted dye, so the process does not require dialysis. Researchers use it for fluorescent conjugate preparation in the near-infrared range.
Cyanine7 NHS ester is an activated, water-soluble cyanine dye supplied for covalent labeling of proteins. Its reactive N-hydroxysuccinimide ester targets primary amino groups, namely the N-terminal amine and lysine residue side chains, which are present on antibodies and many other proteins. Within a defined pH range, the dye forms a stable amide bond with these groups, attaching the near-infrared fluorophore directly to the protein. The dye has an excitation maximum of 750 nm, an emission maximum of 773 nm, and a molar extinction coefficient of 240,600 L mol-1 cm-1.
Researchers use this kit to attach a near-infrared fluorescent label to antibodies and other proteins that carry primary amino groups. The kit is described as suitable for both micro-labeling and large-scale labeling, with 0.1 to 1 mg of protein labeled per reaction. Documented successful labeling targets include Annexin V, protein A/G, 2019-nCov spike, NGAL, and several recombinant protein fragments. Labeling outcome varies with protein solubility in different buffers, pH and temperature stability, protein purity, and accessibility of the labeling site, so a small test labeling is recommended for unfamiliar proteins.
The complete labeling process takes about 90 minutes. The dye is dissolved in N,N-dimethylformamide (DMF) and added to a protein solution at about 2 mg/mL in Labeling Buffer I, then incubated at 37 °C for 30 minutes in the dark. The reaction can optionally be stopped with 1 M Tris (pH 8.7) at 10 µL per 100 µg of protein. Unreacted dye is removed by ultrafiltration through a 10 kDa filtration tube with 1× PBS washes, which replaces desalting by dialysis. Degree of labeling is estimated by scanning absorbance from 230 to 800 nm and reading A280 and A750 on a 1 cm optical path against a 1× PBS blank.
The kit is intended for purified proteins containing primary amino groups, with antibodies as a principal example. Buffer components with free amines, including Tris, glycine, amino acids, imidazole, sodium azide, and ammonium ion, interfere with labeling and should be removed by repeated ultrafiltration with Labeling Buffer I. Carrier proteins such as BSA and gelatin should be removed by affinity or chromatographic methods before labeling. The recommended dye-to-protein molar ratio is 3.6:1 to 11:1 for proteins of 30 to 100 kDa. The unopened kit is stable at 2 to 8 °C for 1 year, and the dye is kept at -20 °C with desiccant and shielded from light. Labeled protein can be stored for 6 months at 2 to 8 °C in the dark with 0.05 to 0.2% Proclin 300 or 0.05% sodium azide plus a stabilizer such as 0.1% BSA, or at -20 °C with an equal volume of glycerol.
| Product Name: | Cyanine7 Labeling Kit |
| SKU: | AKES134 |
| Labeling group: | Cyanine 7 |
| Applications: | Protein labeling; antibody labeling |
| Reactive chemistry: | NHS ester (amine-reactive) |
| Target functional group: | Primary amino groups (N-terminal and lysine side chains) |
| Excitation maximum: | 750 nm |
| Emission maximum: | 773 nm |
| Labeling reaction: | 30 min at 37°C, in the dark |
- Amine-reactive Cyanine7 NHS ester; dye is pre-activated and ready to dissolve in DMF
- Excitation/absorption maximum 750 nm; emission maximum 773 nm
- Labels 0.1–1 mg of protein per reaction
- Whole labeling workflow takes approximately 90 min
- Includes 10 kDa filtration device for buffer exchange without dialysis
- Degree of labeling calculated from A280 and A750 absorbance



Labeling is performed by reacting the Cyanine7 NHS ester with primary amines on the target protein in a labeling buffer at 37°C for 30 min in the dark. Unreacted dye is removed by ultrafiltration. The degree of substitution (DOS) is then determined from absorbance: DOS = (A750 × ε IgG) / (ε Cyanine7 × (A280 − CF280 × A750)). Protein concentration (mg/mL) = (A280 − CF280 × A750) × 150000 / ε IgG.
- Preparation of fluorescently labeled antibodies for near-infrared detection
- Labeling of proteins containing primary amines, such as Annexin V, protein A/G, and recombinant protein fragments
- Labeling of other proteins with free amino groups, with the labeling ratio set by the number of available amines
- Optimization of dye:protein molar ratio to control degree of labeling
| Component | Storage |
| Cyanine7 NHS ester | -20°C, protect from light |
| Labeling Buffer I | 2-8°C |
| DMF | 2-8°C, protect from light |
| 1×PBS (pH 7.4) | 2-8°C |
| 1 M Tris (pH 8.7) | 2-8°C |
| 10 kDa filtration tube | Room temperature |
- Pipettes and tips (0.5–10 µL, 2–20 µL, 20–200 µL, 200–1000 µL)
- UV spectrophotometer, nanodrop, or multifunctional microplate reader
- 37°C incubator
- Centrifuge capable of 12,000×g
- Protein to be labeled (0.1–1 mg per reaction), free of interfering amines such as Tris, glycine, or amino acids
Purified antibodies or other proteins containing primary amino groups
- Bring all reagents to room temperature for 20 minutes before use. Reagents not in use remain refrigerated.
- Prepare the filter device: add 500 µL Labeling Buffer I to the dry filter device, stand at room temperature for 10 minutes, and discard the buffer before adding protein. The filter must remain moist throughout labeling.
- Dissolve 0.1 mg of Cyanine7 NHS ester in 10 µL DMF and stand for 10 minutes until fully dissolved. The resulting concentration is 12.08 mM. Keep the tube covered.
- Concentrate and exchange buffer: place the filter device in a collection tube, add 1 mg of protein, and bring the volume to 0.5 mL with Labeling Buffer I. Centrifuge at 12,000 × g for 10 minutes and discard the liquid in the collection tube. The maximum filter volume is 0.5 mL; for larger volumes, add the sample in several rounds.
- If the protein contains free amino groups, repeat ultrafiltration with Labeling Buffer I to remove them fully.
- Recover the protein: invert the filter device into a new collection tube and centrifuge at 1,000 × g for 2 minutes. Add Labeling Buffer I to the collected protein so the concentration is about 2 mg/mL.
Preparation
- Bring all kit reagents to room temperature for 20 min before use.
- Pre-wet the filter device: add 500 µL Labeling Buffer I to the dry device, stand 10 min at room temperature, and discard the buffer. Keep the device moist throughout.
- Dissolve 0.1 mg Cyanine7 NHS Ester in 10 µL DMF and stand 10 min until fully dissolved. The dye concentration is 12.08 mM. Cover the tube until use.
Labeling
- Concentrate and buffer-exchange: add 1 mg protein and Labeling Buffer I to a final volume of 0.5 mL in the filter device. Centrifuge at 12,000×g for 10 min and discard the filtrate. Repeat if the protein volume exceeds 0.5 mL.
- Recover protein: invert the filter device into a clean collection tube and centrifuge at 1000×g for 2 min. Adjust the protein solution with Labeling Buffer I to a concentration of about 2 mg/mL.
- Label: immediately add 9.9 µL of 12.08 mM Cyanine7 to the protein solution. Mix thoroughly, cap, and incubate at 37°C for 30 min in the dark.
- (Optional) Block: add 10 µL of 1 M Tris (pH 8.7) per 100 µg protein. Mix and incubate at room temperature for 10 min.
Purification and collection
- Bring the reaction to 0.5 mL with 1×PBS, transfer to the filter device, and centrifuge at 12,000×g for 10–30 min. Discard the filtrate.
- Replenish 1×PBS to 500 µL in the filter device and repeat centrifugation 2–3 times, until the ultrafiltrate is nearly colorless.
- Add 0.2 mL 1×PBS to the filter device and pipet gently. Invert the device into a new collection tube and centrifuge at 1000×g for 2 min. The collected solution is the Cyanine7-labeled protein.
DOS = (A750 × εIgG) / (εCyanine7 × (A280 − CF280 × A750)) Protein concentration (mg/mL) = (A280 − CF280 × A750) × 150000 / εIgG
- DOS: average number of Cyanine7 dye molecules per protein (degree of substitution).
- A750: absorbance of the Cyanine7-labeled sample at 750 nm, 1 cm optical path (dimensionless).
- A280: absorbance of the Cyanine7-labeled sample at 280 nm, 1 cm optical path (dimensionless).
- εIgG: molar extinction coefficient of IgG, 210,000 L mol-1 cm-1.
- εCyanine7: molar extinction coefficient of Cyanine7, 240,600 L mol-1 cm-1.
- CF280: correction coefficient of Cyanine7 absorbance at 280 nm, 0.04.
- Protein concentration is reported in mg/mL. The constant 150000 is used as written in the manual.
- The manual defines no dilution factor for these measurements; enter the absorbance values as measured.
How much protein can I label in one reaction?
The kit can label 0.1 to 1 mg of protein each time. Each filter device holds a maximum of 0.5 mL, and loading more than 1 mg of protein per filter can cause leakage and low recovery.
How should I store the kit, the dye, and the labeled protein?
The unopened kit is stored at 2 to 8 °C for 1 year. Dissolved Cyanine7 can be stored at -20 °C or -80 °C for 1 week, and the dye should be kept with desiccant and shielded from light. Labeled protein can be stored for 6 months at 2 to 8 °C in the dark with preservative and stabilizer, or at -20 °C with an equal volume of glycerol.
What should I do if the degree of labeling (DOS) is low or greater than 10?
A low DOS usually reflects interfering components such as Tris, glycine, or sodium azide, or an inaccurate starting protein concentration; remove interferents and quantify the protein before labeling. A DOS greater than 10 indicates excess lysine residues or excess dye; reduce the amount of dye or test different molar ratios, and keep the theoretical protein concentration above 0.5 mg/mL after labeling.
Which substances interfere with labeling?
Tris, glycine, imidazole, sodium azide, thiomersal, Proclin, ammonium ion, BSA, and gelatin can interfere with labeling. Excess DMF also interferes with the reaction, so use the minimum amount needed to dissolve the dye. Mixing the dye with water before labeling or taking it from cold storage without equilibrating to room temperature can cause labeling failure.
Which instrument settings should I use to measure the degree of labeling?
Scan absorbance from 230 nm to 800 nm on an absorbance scanning device, using 1× PBS as the blank. Record A280 and A750 on a 1 cm optical path, and base the result on the full absorption curve rather than a single maximum value. Use 2 µL of labeled sample.
How long does the labeling procedure take?
The whole process takes about 90 minutes. The labeling reaction itself is 30 minutes at 37 °C in the dark, and each ultrafiltration spin is 10 to 30 minutes at 12,000 × g, repeated 2 to 3 times during purification.
| Storage: | Unopened kit at 2-8°C, protected from light; Cyanine7 NHS ester at -20°C, protected from light; filtration tubes at room temperature; dissolved dye at -20°C or -80°C with desiccant |
| Shelf Life: | 1 year (12 months) for the unopened kit |
| Shipping: | Ice bag |
Cautions
- For research use only; not for use in clinical diagnostics.
- Cyanine 7 is susceptible to moisture hydrolysis; equilibrate the dye to room temperature before opening to prevent condensation.
- Protect the dye and labeled protein from light by incubating in the dark and using shading-light storage.
- Remove free amino-group interferents (e.g., Tris, glycine, amino acids) from the protein before labeling, since they compete with the dye.
- Dissolved Cyanine7 is stable only about 1 week at -20°C or -80°C; prepare it fresh for each use.
- Keep the filter device moist throughout the labeling process.