Description
EdU Cell Proliferation Flow Cytometry Assay Kit (Green, FITC)
The EdU Cell Proliferation Flow Cytometry Assay Kit (Green, FITC) measures DNA synthesis in proliferating cells. EdU (5-ethynyl-2-deoxyuridine), a thymidine analog, is incorporated into newly synthesized DNA and detected by a copper-catalyzed click reaction with FITC Azide. The method avoids BrdU antibody steps and is read on a flow cytometer using the FITC channel.
5-ethynyl-2-deoxyuridine (EdU) is a thymidine analog. During DNA synthesis, EdU can replace thymidine and incorporate into newly synthesized DNA. The acetylene group on EdU serves as a chemical handle, so the newly made DNA of proliferating cells can be labeled after incorporation. Direct detection of DNA synthesis is considered the most accurate approach for measuring cell proliferation, and this kit detects incorporated EdU in cells by flow cytometry.
Cell proliferation assays are widely used to evaluate cell viability, genotoxicity, and the effect of antitumor drugs. Earlier approaches had limitations. Radiolabeled nucleoside incorporation involved radioactive contamination and difficulty detecting single cells. The BrdU method, which relies on antibody detection, has many steps, many influencing factors, and poor antibody stability. The EdU method avoids antibodies, is described as convenient, and offers high detection sensitivity, which is why it is positioned as an upgrade to the BrdU method.
Detection depends on a click reaction. After EdU incorporation, cells are fixed and permeabilized, and the alkyne group on EdU reacts with FITC Azide through catalysis by monovalent copper ions, forming a stable triazole ring. The labeled cells are then read on a flow cytometer using the FITC channel. FITC has a maximum excitation wavelength of 490 nm and a maximum emission wavelength of 530 nm. The manual advises detecting samples as soon as possible to avoid fluorescence quenching.
The manual lists both suspension and adherent cells as supported sample types. The EdU labeling concentration varies with cell type, culture medium, cell growth density, and other conditions, so it must be confirmed by preliminary experiments. Copper ions can affect the fluorescence of GFP, RFP, mCherry, and other fluorescent proteins, so the kit is not suitable for cells expressing these proteins. Components should be stored at -20 °C protected from light, and EdU (10 mM) should be stored at -20 °C in aliquots.
| Detection method: | Fluorometric; flow cytometry |
| Sample type: | Cells (suspension and adherent) |
| Assay time: | 2 hours |
| Detection instrument: | Flow cytometer |
| Dye: | FITC |
| Excitation / emission: | 490 nm / 530 nm |
| Channel set: | FITC |
- Antibody-free detection: EdU incorporation followed by a copper-catalyzed click reaction with FITC Azide
- Detects suspension and adherent cells by flow cytometry
- FITC detection channel (Ex/Em 490/530 nm)
- Approximately 2 hour assay time
- Includes EdU, click reaction components, and FITC Azide for direct labeling of newly synthesized DNA
EdU replaces thymidine during DNA synthesis and is incorporated into newly synthesized DNA. The alkyne group on EdU reacts with fluorescently labeled azide probes, here FITC Azide, through catalysis by monovalent copper ions to form a stable triazole ring. This click reaction is rapid. Newly synthesized DNA is labeled with FITC, so proliferating cells can be detected by flow cytometry.
- Cell proliferation assays by flow cytometry
- Evaluation of cell viability
- Genotoxicity assessment
- Evaluation of antitumor drug effects on cell proliferation
- Analysis of DNA synthesis in suspension and adherent cell populations
| Component | Storage |
| EdU (10 mM) | -20°C/-80°C |
| Click Reaction Buffer I | -20°C |
| FITC Azide I | -20°C/-80°C, protect from light |
| CuSO4 | -20°C |
| Click Additive | -20°C |
- PBS with 1% BSA, pH 7.2 to 7.6
- PBS with 1% saponin, pH 7.2 to 7.6
- 4% paraformaldehyde dissolved in PBS
- Deionized water
- Flow cytometer with FITC channel set
- Centrifuge
- 6-well plate (volumes in the protocol are for 6-well plates)
Cells (suspension or adherent)
- Labeling: Culture cells with EdU. The labeling concentration varies with cell type, so use an initial concentration of 10 µM in preliminary experiments and test a concentration gradient to determine the best concentration. Use a cell sample without EdU as a negative control. Refer to the incubation time table for common cell lines and the reference table of concentration and time for EdU incubation.
- Click Additive Solution (prepare before use): Dissolve one vial of Click Additive (220 mg) fully in 1.1 mL deionized water. Aliquot and store at -20 °C. Use aliquots only after any precipitate has fully dissolved.
- Collect cells and centrifuge at 300×g for 5 min. Discard the supernatant.
- Wash cells with 1 mL PBS (with 1% BSA). Centrifuge at 300×g for 5 min and discard the supernatant.
- Fix: Resuspend cells in 1 mL 4% Polyformaldehyde (dissolved in PBS) and mix thoroughly. Incubate at room temperature for 15 min, protected from light. If room temperature is low, as in winter, extend the fixation time or fix overnight at 4 °C.
- Wash: Centrifuge at 300×g for 5 min and discard the supernatant. Resuspend cells in 1 mL PBS (with 1% BSA) and mix thoroughly. Centrifuge again at 300×g for 5 min, discard the supernatant, and resuspend in 1 mL PBS (with 1% BSA).
- Permeabilize: Centrifuge at 300×g for 5 min and discard the supernatant. Resuspend cells in 0.5 mL PBS (with 1% Saponin), mix thoroughly, and incubate at room temperature for 20 min.
- Prepare Click Reaction Solution in the order listed and use within 15 min. For one sample, combine 440 µL Click Reaction Buffer I, 40 µL CuSO4, 1 µL FITC Azide I, and 20 µL Click Additive Solution, for a total of 500 µL. Scale the volumes by sample number (for example, 2 samples: 880 µL, 80 µL, 2 µL, 40 µL). For other well formats, the Click Reaction Solution volume per well is 100 µL (96-well), 150 µL (48-well), 250 µL (24-well), 400 µL (12-well), and 500 µL (6-well).
- Click reaction: Centrifuge at 300×g for 5 min and discard the supernatant. Add 500 µL Click Reaction Solution per well of a 6-well plate (or the volume listed for other formats), mix thoroughly, and incubate at room temperature for 30 min.
- Centrifuge at 300×g for 5 min and discard the supernatant. Resuspend cells in PBS (with 1% Saponin) and mix thoroughly. Detect by flow cytometry as soon as possible.
Cell labeling with EdU
- Label cells with EdU. Start with 10 µM and optimize the concentration and incubation time for your cell type.
- Include an EdU-free cell sample as a negative control.
Fixation and permeabilization
- Collect cells and centrifuge at 300 × g for 5 min. Discard the supernatant.
- Wash cells with 1 mL PBS (1% BSA). Centrifuge at 300 × g for 5 min and discard the supernatant.
- Resuspend cells in 1 mL 4% paraformaldehyde in PBS. Mix well and incubate for 15 min at room temperature, protected from light.
- Centrifuge at 300 × g for 5 min and discard the supernatant. Resuspend cells in 1 mL PBS (1% BSA), mix well, then centrifuge again.
- Resuspend cells in 200 µL PBS (1% BSA) for flow cytometry if proceeding to analysis without click labeling.
- Resuspend cells in 0.5 mL PBS (1% saponin). Mix well and incubate for 20 min at room temperature.
Click reaction and detection
- Prepare Click Additive by dissolving one vial in 1.1 mL deionized water. Aliquot and store at -20°C, protected from light.
- Prepare Click Reaction Solution fresh for each sample in the order listed. Per 500 µL reaction: Click Reaction Buffer I 440 µL, CuSO4 40 µL, FITC Azide I 1 µL, Click Additive 20 µL.
- Use the Click Reaction Solution within 15 min of preparation.
- Centrifuge at 300 × g for 5 min and discard the supernatant. Add 500 µL Click Reaction Solution, mix well, and incubate for 30 min at room temperature, protected from light.
- Centrifuge at 300 × g for 5 min and discard the supernatant. Resuspend cells in PBS (1% saponin), mix well, and analyze by flow cytometry as soon as possible.
Which sample types does the kit support?
The manual lists suspension and adherent cells as supported sample types. Cells are collected by centrifugation at 300×g for 5 min before fixation. Cells expressing GFP, RFP, mCherry, or other fluorescent proteins are not suitable because copper ions affect their fluorescence.
How should the EdU and kit components be stored?
EdU (10 mM) should be stored at -20 °C in aliquots, with 50 µL per vial recommended. The product can be stored at -20 °C for 12 months, protected from light. Click Additive Solution should be aliquoted and stored at -20 °C.
What should I do if my signal is out of range?
No quantitative assay range is given in the sources. The manual recommends a preliminary experiment with a concentration gradient of EdU, starting at 10 µM, and a cell sample without EdU as a negative control to determine the optimal labeling concentration.
What reagent conditions affect results?
Click Additive Solution that has turned brown has expired and should be discarded. If white precipitate forms, invert the vial several times and use it only after it has completely dissolved. Click Reaction Solution must be prepared in the listed order and used within 15 min of preparation.
What instrument settings should I use?
Use a flow cytometer with the FITC channel set. FITC has a maximum excitation wavelength of 490 nm and a maximum emission wavelength of 530 nm. Detect samples as soon as possible to avoid fluorescence quenching.
How long does the assay take?
The product page lists an assay time of 2 hours. In the protocol, fixation takes 15 min at room temperature, permeabilization takes 20 min, and the click reaction takes 30 min. EdU labeling time depends on cell type and is set by preliminary testing and the incubation time table.
| Storage: | -20°C, protected from light |
| Shelf life: | 12 months |
| Shipping: | Ice bag |
| EdU (10 mM) storage: | -20°C/-80°C; aliquot before first use |
Cautions
- For research use only. Not for diagnostic or therapeutic use.
- Copper ions can reduce the fluorescence of GFP, RFP, mCherry, and other fluorescent proteins. This kit is not suitable for cells expressing these proteins.
- Optimize EdU concentration and incubation time for each cell type.
- Protect FITC Azide and reaction mixtures from light.
- Detect samples as soon as possible to avoid fluorescence quenching.
- Prepare Click Reaction Solution fresh and use within 15 min.
- Discard Click Additive if the solution turns brown, as this indicates the reagent has expired.
- If Click Additive shows white precipitate before use, invert several times and use only after it fully dissolves.
- If room temperature is low, extend fixation time or fix overnight at 4°C.
- Ensure cells are completely fixed and permeabilized before EdU labeling.