MAES0169 typical standard curve - Glutathione-S-Transferase (GST) Activity Assay Kit
Key Features

Glutathione-S-Transferase (GST) Activity Assay Kit (MAES0169)

SKU MAES0169
Product Type Assay
Instrument Spectrophotometer(340 nm)
Detection Method Colorimetric method
Sample Type Serum, Plasma, Animal Tissue And Cell
Sensitivity 1 U/L
Range 1-79 U/L
€362

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

Glutathione-S-Transferase (GST) Activity Assay Kit

The Glutathione-S-Transferase (GST) Activity Assay Kit (MAES0169) measures GST activity in serum, plasma, tissue, and cell samples. GST catalyzes the conjugation of reduced glutathione (GSH) to 1-chloro-2,4-dinitrobenzene (CDNB), and the product absorbs at 340 nm. Researchers use the kit to quantify GST activity across the 1-79 U/L detection range in oxidative stress and liver and renal function studies.

Glutathione-S-transferase (GST), also referred to as GSH-ST, is an enzyme that catalyzes the binding of reduced glutathione (GSH) to dinitrobenzene (CDNB). Because this assay reports catalytic activity rather than enzyme abundance, results reflect how much GSH conjugation a sample performs per unit time. The kit therefore quantifies functional GST activity in serum, plasma, tissue, and cell samples. Activity is expressed per minute at 37°C, with one unit defined as the amount of enzyme that conjugates 1 µmol of CDNB and GSH per minute.

Researchers measure GST activity in studies of oxidative stress and of liver and renal function, which are the research areas listed for this kit. Validation data are presented for rat liver, lung, and kidney tissue homogenates, and each matrix requires a different dilution before testing. Comparing GST activity across these tissues, or across experimental conditions within one tissue, is the typical use case for this format.

The reaction is run in a cuvette at 37°C and monitored spectrophotometrically at 340 nm. The powder application solution is prepared by dissolving one vial in 5 mL of double-distilled water. For each tube, 0.1 mL of sample (or extracting solution for the blank) is combined with 0.9 mL of buffer solution and 0.1 mL of powder application solution. Absorbance is read at 340 nm at 20 s (A1), the mixture is incubated at 37°C, and absorbance is read again at 320 s (A2). The product of the GSH and CDNB reaction absorbs at 340 nm, so the rate of absorbance increase is the readout, expressed as ΔA = (A2 − A1)sample − (A2 − A1)blank.

Serum and plasma are assayed directly; if they cannot be assayed the same day, they can be stored at -80°C for one month. Tissue is washed in cold PBS (0.01 M, pH 7.4) and homogenized at 20 mg per 180 µL of extracting solution in a Dounce homogenizer at 4°C. Cells (initially 1×10^6) are washed in PBS and disrupted in 300 µL of extracting solution with an ultrasonic cell disruptor at 4°C. Lysates are centrifuged at 10000×g for 10 minutes, and supernatants are kept on ice. Protein concentration of each supernatant must be measured separately, because tissue and cell results are normalized to protein.

Analytical sensitivity is 1 U/L, and the detection range is 1–79 U/L. Intra-assay precision, determined from 20 replicates of three human serum samples, gave coefficients of variation of 1.6–2.3%. Inter-assay precision, determined from 17 runs in duplicate by three operators, gave coefficients of variation of 4.2–4.4%. Recovery was assessed at low, middle, and high concentrations, with an average recovery of 105% (individual values 103–108%). The standard curve in the manual is provided for reference only, because absorbance values vary with operator, pipetting technique, and temperature.