Description
Lactate Dehydrogenase (LDH) Activity Assay Kit
The LDH Activity Assay Kit (MAES0058) measures lactate dehydrogenase (LDH) activity in serum, plasma, hydrothorax, tissue, and cell samples using a colorimetric endpoint readout. LDH converts lactic acid to pyruvate with coenzyme I as the hydrogen carrier, and the pyruvate is derivatized with 2,4-dinitrophenylhydrazine for absorbance measurement at 450 nm. The kit is for Research Use Only.
Lactate dehydrogenase (LDH) is an enzyme that catalyzes the conversion of lactic acid to pyruvate. In this reaction, coenzyme I acts as a hydrogen carrier. Because the reaction links lactate and pyruvate, LDH activity reflects the glycolysis and energy metabolism pathways that define the kit's research areas. The kit quantifies LDH activity in the sample, reported in U/L for serum, plasma, and hydrothorax fluid and in U/g protein for tissue and cell lysates.
LDH activity is measured to assess liver and renal function and to study glycolysis, lipid metabolism, and energy metabolism. The sources list mouse liver, kidney, and lung tissue, HepG2 cells, and porcine serum as representative sample types. Cited studies apply LDH measurements to acute lung injury, cardiotoxicity, cerebral ischemia/reperfusion injury, myasthenia gravis, and vulvovaginal candidiasis models. The kit is intended for research use only and is not for clinical diagnosis.
The assay is a colorimetric method. LDH converts lactic acid to pyruvate, with coenzyme I as the hydrogen carrier. The pyruvate then reacts with 2,4-dinitrophenylhydrazine to form pyruvate dinitrophenylhydrazone, which is red-brown in alkaline solution. Color depth is proportional to pyruvate concentration. In the protocol, sample wells receive substrate buffer and coenzyme I application solution, then incubate at 37°C for 15 minutes. Chromogenic agent is added, followed by a second 15-minute incubation at 37°C. Alkali reagent is then added, and the plate stands at room temperature for 5 minutes before reading absorbance at 450 nm on a microplate reader (440-460 nm).
Serum, plasma, hydrothorax, tissue homogenates, and cell lysates are supported. Hemolyzed serum should be avoided because LDH activity in red blood cells is about 100 times higher than in serum. Detergents such as SDS, Tween 20, NP-40, and Triton X-100 should not be present in samples, and oxalate anticoagulants should not be used because oxalate inhibits LDH activity. Serum and plasma can be assayed directly. If testing is delayed, they can be stored at -80°C for up to one month. Tissue and cell samples are homogenized in normal saline or PBS, then centrifuged at 10000×g for 10 minutes at 4°C to remove insoluble material. The supernatant is kept on ice until testing.
The analytical sensitivity is 6 U/L. The detection range is 6-500 U/L. Intra-assay precision is 1.8% CV, and inter-assay precision is 2.4% CV, as reported on the product page. The manual reports an average recovery of 98% across three concentration levels, with individual recoveries of 97-99%. Within the manual's precision study, intra-assay CVs were 1.5-2.3% and inter-assay CVs were 2.2-2.6% across three human serum samples.
| Product Name: | LDH Activity Assay Kit |
| SKU: | MAES0058 |
| Product Size: | 96 Assays |
| Sample Type: | Serum, plasma, hydrothorax, tissue, cells |
| Detection Method: | Colorimetric (2,4-dinitrophenylhydrazine derivatization) |
| Detection Instrument: | Microplate reader, 440-460 nm (optimum 450 nm) |
| Assay Time: | 45 min |
| Sensitivity: | 6 U/L |
| Detection Range: | 6-500 U/L |
| Recovery Rate: | 98% |
| Research Area: | Liver and Renal Function; Glycolysis and Lipid Metabolism; Energy Metabolism |
| Sensitivity: | 6 U/L |
| Detection Range: | 6-500 U/L |
| Intra-assay CV: | 1.8% |
| Inter-assay CV: | 2.4% |
| Recovery Rate: | 98% (average; individual levels 97-99%) |
| Sample Volume: | 20 µL per well |
| Assay Time: | 45 min (incubations at 37°C) |
| Detection Wavelength: | 450 nm (440-460 nm range) |
- Colorimetric endpoint readout at 450 nm on a microplate reader (440-460 nm range)
- Sensitivity of 6 U/L and detection range of 6-500 U/L
- Sample types: serum, plasma, hydrothorax, tissue homogenates, and cells
- Sample volume of 20 µL per well; total assay time of 45 min
- Recovery rate of 98% (average of three spike levels)
Using coenzyme I as a hydrogen carrier, LDH catalyzes the conversion of lactic acid to pyruvate. The pyruvate reacts with 2,4-dinitrophenylhydrazine to form pyruvate dinitrophenylhydrazone, which is red-brown in alkaline solution. Color depth is proportional to pyruvate concentration, so LDH activity is calculated from the optical density (OD) measured at 450 nm.
- Measurement of LDH activity in serum and plasma samples
- LDH activity profiling in tissue homogenates (for example, mouse liver, kidney, and lung)
- LDH activity measurement in cell lysates (for example, HepG2 cells)
- LDH activity analysis in hydrothorax fluid from research models
- Enzyme activity studies in glycolysis and energy metabolism
| Component | Quantity | Storage |
| Substrate Buffer | 5 mL × 1 vial | 2-8°C, 12 months |
| Coenzyme I (powder) | 1 vial | 2-8°C, 12 months |
| Chromogenic Agent | 5 mL × 1 vial | 2-8°C, 12 months, protect from light |
| Alkali Reagent | 5 mL × 1 vial | 2-8°C, 12 months |
| Pyruvic Acid (2 µmol/mL) | 1 mL × 1 vial | 2-8°C, 12 months |
| Microplate | 96 wells × 1 | No requirement |
| Plate Sealer | 2 pieces | No requirement |
| Sample Layout Sheet | 1 piece | No requirement |
- Microplate reader capable of 440-460 nm reading (450 nm optimum)
- Micropipettor and multichannel pipette
- Incubator at 37°C
- Ice bath
- Refrigerated centrifuge capable of 10000×g at 4°C (tissue and cell samples)
- Dounce homogenizer (tissue) or ultrasonic cell disruptor (cells)
- Double distilled water
- Normal saline (0.9% NaCl)
- PBS (0.01 mol/L, pH 7.4)
- User-supplied protein concentration assay (required to normalize tissue and cell results to U/g protein)
Serum/plasma
- Avoid hemolyzed serum samples.
- Do not include SDS, Tween 20, NP-40, Triton X-100, or other detergents in the sample.
- Do not use oxalate anticoagulants.
- Detect serum or plasma directly.
- If not detected on the same day, store serum or plasma at -80°C for up to one month.
- Dilution: human serum 10-fold; human plasma 15-30-fold; porcine serum 10-20-fold.
- Diluent: normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).
- For other sample types, perform a pretest to confirm the dilution factor.
Tissue
- Harvest the amount of tissue needed for each assay (initial recommendation 20 mg).
- Wash tissue in cold PBS (0.01 M, pH 7.4).
- Homogenize 20 mg tissue in 180 µL normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4) with a dounce homogenizer at 4°C.
- Centrifuge at 10000×g for 10 minutes at 4°C to remove insoluble material.
- Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant separately for use in the calculation.
- Dilution (10% homogenate): mouse kidney 500-800-fold; mouse lung 500-fold; mouse liver 500-800-fold.
- For other sample types, perform a pretest to confirm the dilution factor.
Cells (adherent or suspension)
- Harvest the number of cells needed for each assay (initial recommendation 1×10^6 cells).
- Wash cells with PBS (0.01 M, pH 7.4).
- Homogenize 1×10^6 cells in 300 µL normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4) with an ultrasonic cell disruptor at 4°C.
- Centrifuge at 10000×g for 10 minutes at 4°C to remove insoluble material.
- Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant separately for use in the calculation.
- Dilution: HepG2 cell homogenate 100-300-fold.
- For other sample types, perform a pretest to confirm the dilution factor.
Reagent preparation
- Keep Coenzyme I on ice during use. Equilibrate other reagents to room temperature before use.
- Coenzyme I working solution: dissolve one vial of Coenzyme I in 1.33 mL double distilled water and mix well. Store at 2-8°C for 15 days, or aliquot and store at -20°C for 1 month.
- Alkali working solution: for each well, mix 20 µL Alkali Reagent with 180 µL double distilled water (200 µL per well). Store at 2-8°C for up to 7 days.
- Standard curve: prepare fresh standards each time and discard after use. Dilute the 2 µmol/mL pyruvic acid standard with double distilled water to 0, 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, and 1.0 µmol/mL (0, 10, 20, 40, 80, 120, 160, and 200 µL of standard, with 400, 390, 380, 360, 320, 280, 240, and 200 µL double distilled water, respectively, in a 400 µL total volume).
Serum (plasma): LDH activity (U/L) = (ΔA450 - b) ÷ a × f × 1000 Tissue and cells: LDH activity (U/gprot) = (ΔA450 - b) ÷ a × f ÷ Cpr × 1000
- ΔA450 = OD(sample) - OD(control), the absorbance at 450 nm after subtracting the control well.
- a and b are the slope and intercept of the standard curve, y = ax + b, where y is the absoluted OD value and x is the concentration in µmol/mL.
- Standard curve absoluted OD values are obtained by averaging duplicate readings and subtracting the mean OD of the blank (Standard #1).
- f is the dilution factor of the sample before testing.
- Cpr is the protein concentration of the sample in gprot/L.
- 1000 converts units: 1 L = 1000 mL.
- One unit is defined as the enzyme amount that generates 1 µmol of pyruvic acid per liter of serum (plasma), or per gram of protein for tissue and cells, at 37°C for 15 minutes.
What sample types can be tested?
The kit measures LDH activity in serum, plasma, hydrothorax, tissue, and cell samples. The manual recommends a pretest for any sample type not listed in the protocol.
How should serum and plasma be stored before testing?
Serum and plasma should be detected directly when possible. If testing does not occur the same day, they can be stored at -80°C for up to one month.
How long are the kit reagents stable, and how should they be stored?
All kit components are stored at 2-8°C for 12 months. The chromogenic agent should be protected from light. Coenzyme I working solution is stable at 2-8°C for 15 days or aliquoted at -20°C for one month.
What should I do if my sample reads outside the detection range?
The detection range is 6-500 U/L. If the concentration is not within this range, perform an extra dilution or concentration of the sample. Include the dilution factor in the calculation.
What substances interfere with the assay?
Hemolyzed serum should be avoided because red blood cell LDH activity is about 100 times higher than serum. Detergents such as SDS, Tween 20, NP-40, and Triton X-100 should not be present, and oxalate anticoagulants inhibit LDH activity.
What instrument settings and assay time are required?