Description
Pepsin Activity Assay Kit
The Pepsin Activity Assay Kit (MAES0284) measures pepsin activity in gastric and intestinal tissue homogenates. Pepsin hydrolyzes a substrate, and the hydrolysate forms a blue product under alkaline conditions that is read at 660 nm. Researchers use the kit to quantify pepsin activity in units normalized to tissue protein concentration.
Pepsin is a protease that catalyzes the hydrolysis of its substrate, and its enzymatic activity is the analyte this kit quantifies. The kit is intended to measure pepsin activity in gastric and intestinal tissue samples and is classified within the Amino Acids and Proteins research area. Because the readout depends on substrate hydrolysis, results reflect enzymatic activity rather than the amount of pepsin protein alone. Activity is normalized to the protein content of each sample, which allows comparison between tissue homogenates prepared at different concentrations. The kit is for research use only and is not intended for clinical diagnosis.
The sources identify gastric and intestinal tissue from rat and mouse as the sample types for this assay, with example data and dilution guidance provided for 20% homogenates of each. This places the kit in studies of digestive tissue physiology, where comparing pepsin activity across the stomach and intestine is the central measurement. Researchers can apply the kit to these tissues to quantify activity in a standardized colorimetric format. The sources do not describe specific disease models, so applications beyond the listed gastric and intestinal tissue types should be confirmed by the user through pretesting.
The assay is a colorimetric, endpoint method. Pepsin in the sample is incubated at 37°C with a precipitating agent and a measuring working solution containing substrate, then the supernatant is transferred to a microplate. Chromogenic agent A and chromogenic agent B are added, and the mixture is incubated at 37°C for 10 min. The hydrolysate reacts with the chromogenic agent under alkaline conditions to form a blue substance with a maximum absorption peak at 660 nm, and color depth is proportional to pepsin activity. Absorbance is read on a microplate reader at 650-670 nm, with 660 nm as the optimum wavelength.
Tissue is harvested, washed in cold PBS (0.01 M, pH 7.4), and homogenized in normal saline (0.9% NaCl) at 4°C. Homogenates are centrifuged to remove insoluble material, and the supernatant is kept on ice for detection. Kit reagents are stored at -20°C for 12 months, and the chromogenic agent B, substrate, and standard solution must be protected from light. The substrate working solution is stored at 2-8°C for up to 2 days, while standard dilutions and the measuring working solution must be prepared fresh and discarded after use.
Reported analytical sensitivity is 0.63 U/mL, and the detection range is 0.63-94.98 U/mL. Intra-assay coefficients of variation ranged from 1.3% to 2.2%, and inter-assay coefficients of variation ranged from 4.8% to 5.6% across three rat gastric tissue samples. Spike recovery averaged 95% across high, middle, and low standard concentrations, with individual recoveries of 93% to 98%. These performance figures are reported in the manual's Appendix I and reflect the test conditions described there.
| Sample type: | Gastric and intestinal tissue homogenates |
| Assay type: | Enzyme activity detection |
| Detection method: | Colorimetric |
| Instrument: | Microplate reader (650-670 nm; optimum wavelength 660 nm) |
| Sensitivity: | 0.63 U/mL |
| Detection range: | 0.63-94.98 U/mL |
| Intra-assay CV: | 1.3-2.2% |
| Inter-assay CV: | 4.8-5.6% |
| Research area: | Amino acids and proteins |
| Detection method: | Colorimetric |
| Wavelength: | 660 nm (optimum); instrument range 650-670 nm |
| Sensitivity: | 0.63 U/mL |
| Detection range: | 0.63-94.98 U/mL |
| Intra-assay CV: | 1.3-2.2% |
| Inter-assay CV: | 4.8-5.6% |
| Average recovery: | 95% (high, middle, and low concentration samples; individual recoveries 93-98%) |
- Colorimetric readout at 660 nm on a microplate reader (650-670 nm)
- Detection range 0.63-94.98 U/mL with sensitivity of 0.63 U/mL
- Intra-assay CV 1.3-2.2% and inter-assay CV 4.8-5.6%
- Validated for gastric and intestinal tissue homogenates, including rat and mouse samples
- Activity expressed in U/mg protein using a protein concentration measurement of the sample
- Stable at -20°C for 12 months; light-sensitive components require shading
Pepsin catalyzes substrate hydrolysis, and the hydrolysate reacts with the chromogenic agent under alkaline conditions to form a blue substance. The blue substance has a maximum absorption peak at 660 nm, and color depth is proportional to pepsin activity. Enzyme activity is calculated from the OD value.
- Measuring pepsin activity in gastric tissue homogenates from rat and mouse
- Measuring pepsin activity in intestinal tissue homogenates
- Comparing pepsin activity across tissue samples normalized to protein concentration
- Amino acid and protein research requiring a colorimetric pepsin activity readout
| Component | Quantity | Storage |
| Reagent 1: Buffer Solution | 55 mL x 2 vials | -20°C, 12 months |
| Reagent 2: Precipitating Agent | 50 mL x 1 vial | -20°C, 12 months |
| Reagent 3: Chromogenic Agent A | 20 mL x 1 vial | -20°C, 12 months |
| Reagent 4: Chromogenic Agent B | 10 mL x 1 vial | -20°C, 12 months, protect from light |
| Reagent 5: Substrate (powder) | 2 vials | -20°C, 12 months, protect from light |
| Reagent 6: Substrate Solvent | 12 mL x 1 vial | -20°C, 12 months |
| Reagent 7: 1 mg/mL Standard Solution | 1.5 mL x 1 vial | -20°C, 12 months, protect from light |
| Microplate | 96 wells x 1 | No requirement |
| Plate sealer | 2 pieces | No requirement |
| Sample layout sheet | 1 piece | No requirement |
- Microplate reader capable of 650-670 nm (optimum 660 nm)
- Incubator set to 37°C
- Water bath set to 75°C
- Centrifuge capable of 3500 r/min and 10000 x g at 4°C
- Dounce homogenizer
- Ice and a 4°C refrigerator
- 2 mL EP tubes
- Normal saline (0.9% NaCl)
- PBS (0.01 M, pH 7.4) for tissue washing
- Protein concentration assay for measuring supernatant protein concentration
- Precision pipettes and tips
Tissue homogenate (gastric and intestinal)
- Harvest the amount of tissue needed for each assay; the initial recommendation is 30 mg.
- Wash the tissue in cold PBS (0.01 M, pH 7.4).
- Homogenize 30 mg of tissue in 120 µL of normal saline (0.9% NaCl) with a Dounce homogenizer at 4°C.
- Centrifuge at 10000 × g for 10 min at 4°C to remove insoluble material. Collect the supernatant and keep it on ice for detection.
- Determine the protein concentration of the supernatant with a separate protein assay, as the protein concentration is required for the calculation.
- Dilution: the recommended dilution factor is 1 for 20% rat gastric, 20% mouse gastric, 20% rat intestinal, and 20% mouse intestinal tissue homogenates (for reference only).
- Diluent: buffer solution is specified in the manual; normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4) is listed in the product information. For other sample types, perform a pretest to confirm the dilution factor.
Reagent preparation
- Equilibrate all reagents to room temperature before use.
- Substrate working solution: dissolve one substrate vial in 5 mL Substrate Solvent. Dissolve completely in a 75°C water bath for 30 min. Store at 2-8°C for up to 2 days.
- 60 µg/mL standard: mix 940 µL Buffer Solution with 60 µL of 1 mg/mL Standard Solution. Prepare on the day of the assay.
- Measuring working solution: mix 195 µL Buffer Solution with 125 µL substrate working solution per 320 µL (scale to the number of test wells). Prepare on the day of the assay.
- Standard curve: dilute the 60 µg/mL standard with Buffer Solution to 0, 12, 18, 24, 36, 42, 48, and 60 µg/mL. For example, 0, 40, 60, 80, 120, 140, 160, and 200 µL of 60 µg/mL standard are combined with 200, 160, 140, 120, 80, 60, 40, and 0 µL of Buffer Solution, respectively. Prepare fresh and discard after use.
Sample preparation
- Wash tissue in cold PBS (0.01 M, pH 7.4).
- Homogenize 30 mg tissue in 120 µL normal saline (0.9% NaCl) with a Dounce homogenizer at 4°C.
- Centrifuge at 10000 x g for 10 min at 4°C. Collect the supernatant and keep on ice.
- Determine the protein concentration of the supernatant with a protein assay.
- Dilute samples as needed. For 20% rat or mouse gastric and intestinal tissue homogenates, the reference dilution factor is 1. For other sample types, perform a pretest to confirm the dilution factor.
Enzymatic reaction
- Control tube: add 40 µL sample to a 2 mL EP tube, then add 400 µL Precipitating Agent.
- Sample tube: add 40 µL sample to a 2 mL EP tube.
- Add 200 µL measuring working solution to the control and sample tubes. Mix and incubate at 37°C for 10 min.
- Add 400 µL Precipitating Agent to the sample tube. Mix and incubate at 37°C for 10 min.
- Centrifuge at 3500 r/min for 10 min. Collect the supernatant for detection.
Chromogenic reaction and reading
- Add 60 µL of each standard to standard wells, 60 µL control supernatant to control wells, and 60 µL sample supernatant to sample wells.
- Add 150 µL Chromogenic Agent A to each well.
- Add 60 µL Chromogenic Agent B to each well.
- Mix with the microplate reader and incubate at 37°C for 10 min.
- Read OD at 660 nm.
Pepsin activity (U/mg prot) = (ΔA660 − b) ÷ a ÷ T × (V1 ÷ V2) ÷ Cpr × f
- ΔA660 = OD(sample) − OD(control), measured at 660 nm.
- a and b are the slope and intercept of the standard curve y = ax + b, where y is the absolute OD value of each standard (mean blank OD subtracted) and x is the standard concentration in µg/mL.
- T is the time of enzymatic reaction, 10 min.
- V1 is the volume of enzymatic reaction, 0.64 mL.
- V2 is the volume of sample in enzymatic reaction, 0.04 mL.
- Cpr is the protein concentration of the sample in mg prot/mL.
- f is the dilution factor of the sample before testing. Use f = 1 for the listed 20% homogenates.
- One unit is defined as the amount of pepsin in 1 mg tissue protein that catalyzes the conversion of substrate to produce 1 µg of product per minute at 37°C.
- Worked example from the manual: with a standard curve of y = 0.0102x + 0.001, sample OD 0.414, control OD 0.379, and protein concentration 0.268 mg prot/mL for 20% rat gastric homogenate, the result is 19.9 U/mg prot.
What sample types can be tested with this kit?
The kit is intended for pepsin activity in gastric and intestinal tissue samples. The manual provides dilution guidance for 20% rat and mouse gastric and intestinal tissue homogenates.
How should samples and reagents be stored?
Kit reagents are stored at -20°C for 12 months, and the chromogenic agent B, substrate, and standard solution should be protected from light. Substrate working solution can be stored at 2-8°C for 2 days, while standards and measuring working solution must be prepared fresh.
What is the detection range, and what should be done if a sample is out of range?
The detection range is 0.63-94.98 U/mL. If the concentration is not within the detection range, an extra dilution or concentration should be taken for the sample.
What are the key points that affect results?
The results are closely related to reagent condition, operation, and environment. Pretesting is recommended for sample types not listed in the manual, and the kit is for research use only, not clinical diagnosis.
What instrument settings are required?
Read absorbance on a microplate reader at 650-670 nm, with 660 nm as the optimum wavelength. Standards and samples are measured at 660 nm after the chromogenic reaction.
How long does the assay take?
The enzymatic reaction involves 10 min at 37°C, a second 10 min incubation at 37°C after adding precipitating agent, and centrifugation for 10 min. The chromogenic reaction requires a further 10 min at 37°C before reading.
| Storage: | -20°C; the chromogenic agent B, substrate, and 1 mg/mL standard solution also need protection from light |
| Shelf Life: | 12 months |
Notes
- For research use only; do not use in clinical diagnosis.
- Store reagents strictly according to the preservation conditions in the kit table.
- Do not mix reagents from different kits.
- Equilibrate all reagents to room temperature before use.
- Centrifuge small-volume reagents before use to ensure sufficient amounts.
- Prepare the standard curve dilutions and measuring working solution fresh on the day of testing and discard unused working standards after use.