Description
Smith (Sm) Antigen (SmA) Human IgA ELISA Kit (SBRS8818)
The Smith (Sm) Antigen (SmA) Human IgA ELISA Kit is an indirect, colorimetric enzyme-linked immunosorbent assay for the detection of human IgA antibodies against Smith (Sm) antigen in serum and plasma samples. Plates are pre-coated with Sm antigen, and a Positive Control containing anti-antigen antibody is supplied to generate a calibration curve for result interpretation.
Antigen-specific IgA in the sample binds to the coated wells and is detected with a biotinylated anti-human IgA antibody, followed by HRP-Streptavidin and TMB substrate. The Stop Solution changes the color from blue to yellow, and the intensity, read at 450 nm, is proportional to the amount of anti-Sm antigen IgA present.
| Product SKU: | SBRS8818 |
| Size: | 1 Plate Kit, 2 Plate Kit, 5 Plate Kit |
| Species: | Human |
| Sample Types: | Plasma, Serum |
| Design Principle: | Indirect |
| Method of Detection: | Colorimetric |
| Assay Type: | Quantitative |
| Sample Dilution: | 1:1500 in 1X Sample Diluent |
| Calibration Range: | 1.37 – 1000 Unit/ml (Positive Control) |
| Detection Wavelength: | 450 nm |
| Component | Quantity |
|---|---|
| Pathogen antigen coated 96-well Microplate | 12 strips x 8 wells |
| Wash Buffer Concentrate (20X) | 25 ml |
| Positive Control | 1 vial |
| Biotinylated Anti-Human IgA | 1 vial |
| Biotinylated Anti-Positive Control | 1 vial |
| HRP-Streptavidin concentrate | 1 vial |
| TMB One-Step Substrate Reagent | 12 ml |
| Stop Solution | 8 ml |
| Assay Diluent B (5X) | 15 ml |
| Sample Diluent (5X) | 25 ml |
- Prepare all reagents, samples and positive control calibration curve as instructed.
- Add 100 µl positive control or sample (diluted 1:1500) to each well.
- Incubate 1 hour at room temperature with gentle shaking.
- Add 100 µl prepared Biotinylated Anti-Positive Control and Biotinylated Anti-Human IgA Antibody into respective wells.
- Incubate 1 hour at room temperature with gentle shaking.
- Add 100 µl prepared HRP-Streptavidin solution to each well.
- Incubate 30 minutes at room temperature with gentle shaking.
- Add 100 µl TMB One-Step Substrate Reagent to each well.
- Incubate 30 minutes at room temperature in the dark with gentle shaking.
- Add 50 µl Stop Solution to each well.
- Read at 450 nm immediately.
The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C. For prepared reagent storage, see the technical manual.