Description
| Product Name: | Super Sensitivity Chemiluminescent Substrate (ECL) Detection Kit |
| SKU: | AGEL3540 |
| Size: | 50 mL / 100 mL / 500 mL |
| Applications: | Western Blot, ELISA |
| RUO: | Research-Use-Only |
The Super Excellent Chemiluminescent Substrate (ECL) Detection Kit is a horseradish peroxidase (HRP) substrate, which can be used to detect horseradish peroxidase (HRP) labeled proteins or nucleic acids, analyze protein content by Western blot or ELISA, and is compatible with film and digital development system.
The special ingredients contained in this product can effectively reduce non-specific luminescence and background luminescence, even if exposed for a long time, the background is still extremely low.
The signal of this product decays slowly, and the luminescence is not significantly weakened after 30 min, and the luminous intensity can still reach about 70% of the highest luminous intensity after 120 min.
For Research Use Only.
| Component | Quantity | Storage | ||
| 50 mL | 100 mL | 500 mL | ||
| Super ECL Substrate A | 25 mL | 50 mL | 250 mL | 2~8°C |
| Super ECL Substrate B | 25 mL | 50 mL | 250 mL | 2~8°C |
| Manual | One Copy | - | ||
1. Follow the step of Western Blotting to block the membrane and incubate the primary/secondary antibody.
2. Wash the membrane with TBST for 3 times, 5 min each time.
3. Prepare ECL Working Solution by mixing equal parts of the ECL Substrate A and ECL Substrate B.
Note: Prepare the working solution before use, and change the pipette tips during the suction process.
4. Take an appropriate amount of mixed ECL Working Solution and add it to the membrane.
5. Adjust the exposure time according to the intensity of the luminous intensity.
| Storage & Expiry: | Store at 2~8°C for 12 months. |
| Background: | The special ingredients contained in this product can effectively reduce non-specific luminescence and background luminescence, even if exposed for a long time, the background is still extremely low. |
| Signal Stability: | The signal of this product decays slowly, and the luminescence is not significantly weakened after 30 min, and the luminous intensity can still reach about 70% of the highest luminous intensity after 120 min. |
Important Notes:
1. Before using this product, the imprinting film must be thoroughly washed, otherwise it may cause the background to rise.
2. ECL Substrate A and ECL Substrate B must be prepared before use, and change the pipette tips during the suction process.
3. Do not expose ECL working solution to sunlight or strong light, otherwise it will cause its inactivation, and laboratory light will have little effect on the working solution.
4. NaN3 inhibits HRP activity, NaN3 should be avoided during the experiment.
What can this kit be used for?
It is a horseradish peroxidase (HRP) substrate for detecting HRP-labeled proteins or nucleic acids and analysing protein content by Western blot or ELISA. It is compatible with film and digital development systems.
How do I prepare the working solution?
Mix equal parts of ECL Substrate A and ECL Substrate B. Prepare the working solution before use and change the pipette tips during the suction process.
How should I store the kit?
Store at 2~8°C for 12 months.
Is there anything that interferes with the assay?
NaN3 inhibits HRP activity and should be avoided during the experiment. Do not expose the ECL working solution to sunlight or strong light, as this causes inactivation; laboratory light has little effect.
How long does the signal last?
The signal decays slowly: luminescence is not significantly weakened after 30 min, and the luminous intensity can still reach about 70% of the highest luminous intensity after 120 min.