Description
AF488-11-dUTP
AF488-11-dUTP (AKES087) is a fluorescein-labeled deoxyuridine triphosphate for detecting DNA 3'-OH termini generated during apoptosis. Terminal deoxynucleotidyl transferase (TdT) incorporates the dUTP at broken DNA ends, and the AF488 signal is read by fluorescence microscopy or flow cytometry. It is used in TUNEL-type apoptosis assays on paraffin sections, frozen sections, and cell slides. For research use only.
AF488-11-dUTP is a modified deoxyuridine triphosphate carrying a fluorescein-based dye. Terminal deoxynucleotidyl transferase (TdT) can attach it to the 3'-OH terminus of DNA. The dye and the nitrogenous base are separated by an 11-atom chain, a design that reduces static quenching of fluorescence and improves the efficiency of nucleotide binding to the 3'-OH terminus. Its biological relevance lies in the DNA breaks it labels, which arise during apoptosis.
Chromosomal DNA breakage is a key marker event in apoptosis. Double-strand breaks in apoptotic cells produce a series of DNA 3'-OH termini, and a gap in one strand creates the same end. Researchers use these exposed termini as a marker to detect apoptotic cells and to localize DNA fragmentation within a tissue section or cell slide. Because the label is tied to the break itself, the signal reflects the presence of these ends rather than a general cell stain.
In practice, TdT incorporates the labeled dUTP onto the 3'-OH termini of the broken DNA. The fluorescein conjugate that results can then be read by flow cytometry or by fluorescence microscopy. For fluorescence microscopy, the product is designated for a FITC filter set, with excitation and emission at 495 nm and 519 nm, respectively. The method is a fluorometric readout, so signal intensity is observed directly from the labeled ends.
The listed sample types are paraffin sections, frozen sections, and cell slides, and the listed detection instrument is a fluorescence microscope. The reagent should be stored at -20°C in the dark, where it is stable for 12 months. Repeated freezing and thawing should be avoided, and the reagent should not be vortexed. The product ships on ice bags.
| Product: | AF488-11-dUTP |
| SKU: | AKES087 |
| Dye: | AF488 |
| Excitation / Emission: | 495 nm / 519 nm |
| Channel set: | FITC |
| Filter set: | FITC |
| Detection method: | Fluorometric |
| Sample types: | Paraffin section; frozen section; cell slide |
| Detection instrument: | Fluorescence microscope; flow cytometer |
| Intended use: | Research use only |
- Fluorescein (AF488) dUTP conjugate for TdT-mediated 3'-OH end labeling
- 11-atom linker between the fluorophore and the nitrogenous base
- Excitation/emission 495/519 nm; FITC filter set compatible
- Detection by fluorescence microscopy or flow cytometry
- Supplied at 1 nmol/µL
- Stored at -20°C, protected from light, for 12 months
DNA double-strand breaks in apoptotic cells, or gaps in one strand, expose 3'-OH termini. Under the action of terminal deoxynucleotidyl transferase (TdT), the fluorescein-labeled dUTP is linked to the 3'-OH terminus of the broken DNA. The fluorescence of the dUTP conjugate is then detected by flow cytometry or fluorescence microscopy.
- Detection of DNA 3'-OH breaks as a marker of apoptosis in tissue and cell preparations
- TUNEL-type in situ apoptosis assays on paraffin sections and frozen sections
- Apoptosis analysis in cell slides by fluorescence microscopy
- Quantification of labeled apoptotic cells by flow cytometry
- Terminal deoxynucleotidyl transferase (TdT) and its reaction buffer
- Fluorescence microscope with FITC filter set, or flow cytometer
- Lab coat and disposable gloves
- Prepare paraffin sections, frozen sections, or cell slides for in situ labeling.
- Label the 3'-OH termini of fragmented DNA with AF488-11-dUTP using terminal deoxynucleotidyl transferase (TdT).
- Detect the AF488 fluorescence by fluorescence microscopy or flow cytometry (Ex/Em 495/519 nm).
Which sample types are supported?
The listed sample types are paraffin sections, frozen sections, and cell slides. The listed detection instrument is a fluorescence microscope.
How should the reagent be stored and handled?
Store the reagent in the dark at -20°C for 12 months. Avoid repeated freezing and thawing, and do not vortex the reagent.
Which filter set and wavelengths should I use?
The product is designated for a FITC filter set, with excitation and emission at 495 nm and 519 nm. Fluorescence can be read on a fluorescence microscope.
Can the signal be read by flow cytometry?
Yes. The manual states that fluorescence of the dUTP conjugate can be detected by flow cytometry or by fluorescence microscopy.
What safety precautions apply?
This product is for research use only. Wear a lab coat and disposable gloves before performing experiments.
| Storage: | -20°C, protected from light |
| Shelf life: | 12 months |
| Handling: | Avoid repeated freezing and thawing; do not vortex |
| Shipping: | Ice bag |
Cautions
- For research use only. Not for diagnostic or therapeutic use.
- Wear a lab coat and disposable gloves during all experiments.
- Store in the dark at -20°C. Avoid repeated freezing and thawing.
- Do not vortex.