Description
FITC-11-dUTP
FITC-11-dUTP (AKES086) is a fluorescein-labeled deoxyuridine triphosphate that is incorporated at DNA 3'-OH termini by terminal deoxynucleotidyl transferase (TdT). It is used to detect DNA strand breaks associated with apoptosis. Labeled termini are read by fluorescence microscopy or flow cytometry. For research use only.
FITC-11-dUTP is a fluorescein-labeled modified triphosphate that serves as a nucleotide substrate for terminal deoxynucleotidyl transferase (TdT). The fluorescein is linked to the nitrogenous base through an 11-atom chain. Chromosomal DNA breakage is an important marker event in apoptotic cells. Double-strand breaks and single-strand gaps generate exposed 3'-OH termini, and the labeled dUTP is incorporated onto these ends, making the reagent a marker of DNA breakage in cell death.
Researchers use FITC-11-dUTP to identify apoptotic cells in situ, where the spatial distribution of dying cells within a sample is the question of interest. Because the label is incorporated only at DNA 3'-OH termini, the signal reports cells with DNA breaks rather than total DNA content. The reagent therefore suits studies that compare apoptosis across tissue regions, cell populations, or treatment conditions, and experiments that require cell-level readout by flow cytometry.
In practice, TdT adds the fluorescein-labeled dUTP to the 3'-OH termini of fragmented DNA. The conjugate is detected with a FITC filter set, with excitation and emission at 490 nm and 520 nm, respectively. Fluorescence can be read on a fluorescence microscope or a flow cytometer. The 11-atom linker is designed to prevent static quenching of the fluorescein and to improve the efficiency of nucleotide binding to the 3'-OH terminus of DNA.
The reagent has been used with paraffin sections, frozen sections, and cell slides. Samples should be handled as fixed tissue or cell preparations that retain accessible DNA ends for TdT labeling. Store the product at -20°C in the dark, where it is stable for 12 months. Avoid repeated freezing and thawing, and do not vortex the solution. It is shipped on ice bags and is for research use only.
| Product name: | FITC-11-dUTP |
| SKU: | AKES086 |
| Dye: | FITC |
| Excitation/Emission: | 490/520 nm |
| Detection method: | Fluorometric |
| Detection instruments: | Fluorescence microscope; flow cytometer |
| Intended use: | Research use only |
- FITC-labeled dUTP for TdT-mediated 3'-OH end labeling
- 11-atom linker between fluorescein and the nitrogenous base
- Linker reduces static quenching of fluorescence and improves nucleotide incorporation
- Excitation/emission 490/520 nm (FITC filter set)
- Compatible with fluorescence microscopy and flow cytometry readouts
- Stable at -20°C for 12 months, protected from light
TdT catalyzes the addition of FITC-labeled dUTP to the 3'-OH ends of fragmented DNA, including DNA double-strand breaks in apoptotic cells and single-strand gaps. The incorporated fluorescein signal is then detected by flow cytometry or fluorescence microscopy.
- Detection of DNA fragmentation in apoptosis research
- TdT-mediated labeling of DNA 3'-OH termini in cell and tissue preparations
- Fluorescence microscopy readout of apoptotic cells
- Flow cytometry analysis of apoptotic cell populations
Which sample types can I use with FITC-11-dUTP?
The product is listed for paraffin sections, frozen sections, and cell slides. Detection is based on fluorescence of the dUTP conjugate at 3'-OH ends of fragmented DNA.
How should I store FITC-11-dUTP?
Store the product at -20°C in the dark. The stated shelf life is 12 months under these conditions. Avoid repeated freezing and thawing.
Can I vortex the reagent before use?
Vortexing is not recommended. Mix gently and avoid repeated freeze-thaw cycles to maintain performance.
What instrument settings should I use for detection?
Use a FITC filter set with excitation at 490 nm and emission at 520 nm. Read the signal on a fluorescence microscope or a flow cytometer.
Why does the dUTP have an 11-atom chain between fluorescein and the base?
The 11-atom chain prevents static quenching of fluorescence. It also improves the efficiency of nucleotide binding to the 3'-OH terminus of DNA.
| Storage temperature: | -20°C |
| Storage conditions: | Store in the dark (protect from light) |
| Shelf life: | 12 months |
| Freeze-thaw: | Avoid repeated freezing and thawing |
| Handling: | Not recommended to vortex |
| Shipping: | Ice bag |
Cautions
- For research use only. Not for diagnostic or therapeutic use.
- Wear a lab coat and disposable gloves during experiments.
- Avoid repeated freezing and thawing.
- Do not vortex.