100% Quality Guarantee
PhD-Level Technical Support
MAES0009 typical standard curve - Alanine Aminotransferase (ALT/GPT) Activity Fluorometric Assay Kit
Key Features

Alanine Aminotransferase (ALT/GPT) Activity Fluorometric Assay Kit (MAES0009)

SKU MAES0009
Product Type Assay
Detection Method Fluorometric
Instrument Microplate Reader
Sample Type Serum, Plasma, Animal Tissue
Sensitivity 0.01 U/L
Range 0.01-0.83 U/L
Assay Time 75 min
Shipping Gel Pack
Research Area Diabetes & Obesity
Research Area Enzyme Activity
€670

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

Alanine Aminotransferase (ALT/GPT) Activity Fluorometric Assay Kit

The Alanine Aminotransferase (ALT/GPT) Activity Fluorometric Assay Kit (MAES0009) measures ALT enzyme activity in serum, plasma, and animal tissue homogenates. ALT activity is coupled to pyruvate production, which is converted by pyruvate oxidase and peroxidase into a fluorescent product read at Ex/Em 535/587 nm. Researchers use the kit to quantify ALT activity as a liver-related enzyme marker in research studies.

Alanine aminotransferase (ALT, also designated GPT) is an enzyme that catalyzes the amino conversion reaction between alanine and α-ketoglutaric acid. The reaction yields pyruvic acid and glutamic acid, linking amino acid metabolism to the pyruvate pool. Because pyruvate is the product measured here, ALT activity can be quantified by coupling pyruvate to a detectable signal, which is the basis of this kit. The kit measures ALT activity in animal tissue, serum, plasma, and other liquid samples and is supplied for research use only.

ALT activity is reported under the Liver and Renal Function research area, which defines the kit's primary research context. Researchers use this assay to measure enzyme activity in serum and plasma and in tissue homogenates from heart, spleen, liver, kidney, and lung. The example analyses in the manual include rat serum, rat kidney, mouse heart, and rat muscle homogenates, which illustrates the sample types covered by the protocol. Comparing activity across these matrices requires consistent handling and dilution, so the kit defines a recommended dilution factor for each sample type.

The assay uses a coupled enzymatic reaction. ALT-generated pyruvate is oxidized by pyruvate oxidase to produce H2O2, which, in the presence of peroxidase, converts a non-fluorescent substance into a fluorescent product. Each well receives 20 µL of standard or sample, followed by 100 µL of reaction working solution containing buffer, probe, enzyme working solution, and substrate solution. After mixing for 5 s and standing for 3 min at room temperature, the initial fluorescence (F1) is read. The plate is then incubated for 60 min at room temperature, protected from light, and a second reading (F2) is taken at excitation 535 nm and emission 587 nm. The change, ΔF = F2 − F1, is used for samples, and the standard curve is plotted using F2 of the standards because their fluorescence does not change.

Serum, plasma, and other liquid samples are suitable, as are animal tissue homogenates. Cloudy liquids should be clarified by centrifugation before testing, and tissues are homogenized in cold buffer and cleared by centrifugation. Keep supernatants on ice during testing. Liquid samples that are not assayed on the day of collection can be stored at -80°C for one month. The diluent is buffer solution (normal saline or PBS, 0.01 M, pH 7.4). Sample types not listed in the dilution table require a pretest to confirm the appropriate dilution factor.

The analytical sensitivity is 0.01 U/L, determined by adding two standard deviations to the mean O.D. of 20 zero-standard replicates and calculating the corresponding concentration. The stated detection range is 0.01 to 0.83 U/L. Intra-assay precision, measured on three human serum samples in 20 replicates, was 2.1 to 2.5% CV. Inter-assay precision, from 20 assays in duplicate performed by three operators on the same three samples, was 9.5 to 10.0% CV, with mean values of 0.10, 0.35, and 0.65 U/L. Standard fluorescence values are provided for reference only because they vary with operator, pipetting technique, and temperature.