Angiotensin Converting Enzyme 1 (ACE1) Inhibitor Screening Kit (MAES0494)

SKU MAES0494
Size 96 Assays
€1,099

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

Angiotensin Converting Enzyme 1 (ACE1) Inhibitor Screening Kit

The Assay Genie Angiotensin Converting Enzyme 1 (ACE1) Inhibitor Screening Kit (MAES0494) measures the inhibitory effect of test compounds on ACE1 activity using a fluorometric readout. ACE1 cleaves a substrate to release fluorescent products, and inhibition is calculated from the reduction in fluorescence relative to a total enzyme control. The kit is intended for screening compounds that act on ACE1 and includes enalapril as an ACE1 inhibitor positive control.

Angiotensin Converting Enzyme 1 (ACE1), also known as angiotensin converting enzyme (ACE), kininase II, and peptidyl-carboxylpeptidase, is a key component of the renin-angiotensin system (RAS). Within this pathway, angiotensin is converted into angiotensin II. Angiotensin II strongly contracts vascular smooth muscle, which increases peripheral vascular resistance and can raise blood pressure. Because excessively high ACE1 activity can directly elevate blood pressure, the enzyme is a regulatory target. ACE1 inhibitors lower blood pressure by suppressing its activity.

Researchers use this kit to screen compounds for activity against ACE1, identifying candidate molecules that act as ACE1 inhibitors. The stated research area is inhibitor screening, and the manual describes the intended use as screening compound samples for ACE1 inhibition. The physiological context is blood pressure regulation, since elevated ACE1 activity drives vascular constriction and hypertension-related pathways that ACE1 inhibitors are designed to counteract. Enalapril, an ACE1 inhibitor, is included as a positive control so that inhibition rates can be compared against a known reference.

The assay is fluorometric. ACE1 catalyzes decomposition of a substrate that releases fluorescent products. When an inhibitor is present, formation of these fluorescent products is reduced, and inhibitor effect is determined from the degree of suppression relative to a total enzyme well. Enzyme working solution is incubated with the sample at 37°C for 20 min. Substrate working solution is then added to each well, mixed for 5 s, and incubated at 37°C for 10 min. Fluorescence is read on a microplate reader at an excitation of 320 nm and an emission of 420 nm, using a black 96-well microplate.

The manual recommends diluting samples with double-distilled water. For test compounds with poor water solubility, DMSO can be used to prepare a high-concentration solution that is then diluted with double-distilled water, keeping DMSO below 5% in the reaction system. Kit reagents should be stored at -20°C, protected from light, for 12 months, and all reagents should be equilibrated to 25°C before use. The reconstituted enzyme solution can be stored at -20°C for 7 days, while enzyme and substrate working solutions must be prepared on the day of use and used within 8 h.

The reported inter-assay precision is CV 0.3-9.2%, and the intra-assay precision is CV 0.2-3.3%. Each assay well uses 10 µL of sample, and the total assay time is 50 min. The performance appendix presents an inhibition curve generated with enalapril, the ACE1 inhibitor used as the reference compound in the kit. The kit is for research use only and must not be used for clinical diagnosis.