Description
Annexin V-Cyanine5 Reagent
Annexin V-Cyanine5 Reagent (AKES015) is an Annexin V conjugate labeled with Cyanine5 for detecting apoptotic cells. Annexin V binds phosphatidylserine (PS) on the outer leaflet of the apoptotic cell membrane in a calcium-dependent manner. Researchers use it with membrane-impermeable DNA dyes to distinguish cells at different apoptotic stages by flow cytometry or fluorescence microscopy.
Annexin V is a member of the annexin family of proteins that binds phosphatidylserine (PS) in a calcium-dependent manner. The Annexin V-Cyanine5 Reagent is the Cyanine5-conjugated format of this protein, developed to identify apoptotic cells. Its target is PS exposed on the outer leaflet of the apoptotic cell membrane, so the reagent reports a membrane change that accompanies apoptosis. Binding is specific to this exposed PS, which allows apoptotic cells to be distinguished within a cell population.
Researchers use Annexin V staining to study apoptosis and to separate cells at different apoptotic stages. Combining Annexin V with a membrane-impermeable DNA dye, such as Propidium Iodide (PI), 7-Aminoactinomycin D (7-AAD), or 4',6-Diamidino-2-Phenylindole (DAPI), resolves these stages. Annexin V single-positive cells are early apoptotic, Annexin V and PI double-positive cells are necrotic or late apoptotic, and PI single-positive events are naked nuclei. The sources illustrate this with Jurkat cells treated with 5 µM camptothecin for 4 h.
In practice, cells are harvested, washed with PBS, and resuspended in 1× Annexin V Binding Buffer. Annexin V-Cyanine5 Reagent and the DNA dye are added to each tube, and the cells are gently vortexed. Incubation proceeds at room temperature for 15 to 20 min in the dark. Cyanine5 has excitation and emission maxima of 650 nm and 670 nm, respectively, and the readout is by flow cytometry or fluorescence microscopy. The APC channel is the recommended channel set for flow cytometry.
The reagent is intended for cell samples. Suspension cells generated during apoptosis induction are collected directly, while adherent cells are detected together with the suspension cells collected from the same culture. Mechanical damage during adherent cell digestion should be minimized. Trypsin solutions should contain as little EDTA as possible, because EDTA interferes with Annexin V binding to PS; if EDTA-containing trypsin is used, cells must be washed thoroughly. Stained cells should be analyzed immediately, or kept on ice in the dark and analyzed within 1 h.
| Name: | Annexin V-Cyanine5 Reagent |
| SKU: | AKES015 |
| Pack Size: | 50 Tests, 200 Tests |
| Application: | Annexin V detection of apoptotic cells |
| Detection method: | Fluorometric |
| Sample type: | Cell samples |
| Assay time: | 40 min |
| Detection instrument: | Flow cytometer or fluorescence microscope |
| Dye type: | Cyanine5 |
| Ex/Em: | 650/670 nm |
| Channel set: | APC |
| Other reagents required: | Annexin V Binding Buffer, PBS, deionized water |
- Annexin V conjugated to Cyanine5 (Ex/Em 650/670 nm), detected in the APC channel
- Calcium-dependent binding to phosphatidylserine on the outer leaflet of apoptotic cells
- Compatible with flow cytometry or fluorescence microscopy
- Stains in approximately 15-20 min at room temperature in the dark
- Compatible with PI, 7-AAD, or DAPI for apoptotic-stage discrimination
- Research Use Only
Annexin V-Cyanine5 binds specifically to phosphatidylserine exposed on the outer leaflet of apoptotic cell membranes. Bound reagent is detected by flow cytometry or fluorescence microscopy using the Cyanine5 fluorophore (Ex/Em 650/670 nm). Binding depends on calcium, so the Annexin V Binding Buffer is used during staining.
- Detection of early apoptotic cells (Annexin V-positive, DNA dye-negative) by flow cytometry
- Discrimination of early apoptotic, necrotic, and late apoptotic cells in multiparameter assays with PI, 7-AAD, or DAPI
- Fluorescence microscopy of phosphatidylserine exposure on apoptotic cells
- Time-course studies of apoptosis induction with chemical or biological treatments
| Component | Quantity | Storage |
| Annexin V-Cyanine5 Reagent | 50 Tests: 125 µL × 2; 200 Tests: 500 µL × 2 | 2–8°C, protect from light |
- Annexin V Binding Buffer, 1× working solution
- PBS
- Deionized water
- DNA dye for co-staining: PI, 7-AAD, or DAPI (user-supplied)
- Centrifuge capable of 300 ×g
- Flow cytometer (APC channel) or fluorescence microscope
- Suspension or harvested cells, 1–5×105 cells per tube
- Microcentrifuge tubes and ice
Cells (suspension cells)
- Induce apoptosis in suspension cells with the reagents of interest.
- Collect the cell culture and centrifuge at 300 × g for 5 min. Discard the supernatant.
- Add PBS to wash the cells, resuspend gently, and count the cells.
- Split the cell suspension into tubes, with 1 to 5 × 10^5 cells per tube. Centrifuge at 300 × g for 5 min and discard the supernatant.
- Add PBS to wash the cells, centrifuge at 300 × g for 5 min, and discard the supernatant.
- Resuspend the cells in 500 µL of 1× Annexin V Binding Buffer per tube.
- Add 5 µL of Annexin V-Cyanine5 Reagent and 5 µL of DNA dye (PI, 7-AAD, or DAPI) to each tube.
- Gently vortex the cells and incubate at room temperature for 15 to 20 min in the dark.
- Analyze immediately. Otherwise, place the cells on ice in the dark and analyze within 1 h.
Cells (adherent cells)
- Induce apoptosis in the adherent cells with the reagents of interest.
- Collect the suspension cells generated after apoptosis induction and combine them with the subsequently harvested adherent cells.
- Minimize mechanical damage during digestion of the adherent cells.
- If trypsin containing EDTA is used, wash the cells thoroughly after harvesting to remove EDTA.
- Proceed with the staining steps for suspension cells, starting with the 500 µL of 1× Annexin V Binding Buffer resuspension.
Suspension cells
- Induce apoptosis with the treatment of interest. Collect cells, centrifuge at 300 ×g for 5 min, and discard the supernatant.
- Wash cells with PBS, resuspend gently, and count the cells.
- Aliquot 1–5×105 cells per tube, centrifuge at 300 ×g for 5 min, and discard the supernatant.
- Wash cells with PBS, centrifuge, and discard the supernatant.
- Resuspend cells in 500 µL of 1× Annexin V Binding Buffer.
- Add 5 µL of Annexin V-Cyanine5 Reagent and 5 µL of DNA dye (PI, 7-AAD, or DAPI) to each tube.
- Gently vortex and incubate at room temperature for 15–20 min in the dark.
- Analyze immediately. Alternatively, keep cells on ice in the dark and analyze within 1 h.
Adherent cells
- Collect the suspension cells generated during apoptosis induction and combine them with the adherent cells harvested afterward before staining.
- Minimize mechanical damage during digestion. Use trypsin without EDTA where possible, or wash thoroughly after harvesting if EDTA-containing trypsin is used.
What sample type does this reagent support?
The reagent is designed for cells, including suspension cells and adherent cells. For adherent cells, the suspension cells generated during apoptosis induction should be collected and analyzed together with the adherent cells.
How should the Annexin V-Cyanine5 Reagent be stored?
Store the reagent at 2 to 8 °C in the dark for one year, and protect it from light. Avoid freeze/thaw cycles.
Why is my apoptosis staining weak or inconsistent?
Check that the trypsin used for adherent cells does not contain EDTA, or wash cells thoroughly if it does, because EDTA affects Annexin V binding to phosphatidylserine. Also protect samples from extended exposure to direct light to prevent fluorophore quenching.
Which instrument settings should I use?
Analyze stained cells on a flow cytometer using the APC channel set, with Cyanine5 excitation at 650 nm and emission at 670 nm. Fluorescence microscopy can also be used for detection.
How long does the assay take, and when should samples be analyzed?
The staining incubation takes 15 to 20 min at room temperature in the dark, and the product page lists an assay time of 40 min. Analyze cells immediately after staining, or keep them on ice in the dark and analyze within 1 h.
| Storage: | 2–8°C, protect from light |
| Shelf life: | 12 months |
| Freeze/thaw: | Avoid freeze/thaw cycles |
| Shipping: | Ice bag |
Cautions
- For Research Use Only. Not for use in diagnostic or therapeutic procedures.
- Detect samples as soon as possible after staining to avoid increases in apoptosis or necrosis.
- Avoid extended exposure of samples to direct light to prevent fluorophore quenching.
- EDTA inhibits Annexin V binding to phosphatidylserine. Avoid EDTA-containing trypsin where possible, and wash cells thoroughly if it is used.
- When analyzing adherent cells, include the suspension cells collected after apoptosis induction.
- Wear a lab coat and disposable gloves during experiments.