100% Quality Guarantee
PhD-Level Technical Support
beta-Hydroxybutyrate (beta-HB) Colorimetric Assay Kit typical standard curve
Key Features

beta-Hydroxybutyrate (beta-HB) Colorimetric Assay Kit (MAES0217)

SKU MAES0217
Product Type Assay
Instrument Microplate Reader
Detection Method Colorimetric
Sample Type Serum, Plasma, Urine, Animal Tissue
Sensitivity 0.01 mmol/L
Range 0.01-2.00 mmol/L
Assay Time 60 min
€450

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

beta-Hydroxybutyrate (beta-HB) Colorimetric Assay Kit

The beta-Hydroxybutyrate (beta-HB) Colorimetric Assay Kit (MAES0217) quantifies beta-hydroxybutyrate in serum, plasma, urine, and animal tissue homogenates. The assay uses beta-hydroxybutyrate dehydrogenase, NAD+, and WST-8 to generate a yellow product read at 450 nm. Researchers use it to measure ketone body levels in metabolic and energy metabolism studies.

β-Hydroxybutyrate (β-HB), C4H8O3, is a ketone body that accounts for about 75% of total ketone bodies. Its formation from acetoacetic acid is promoted by NADH, and β-hydroxybutyrate dehydrogenase catalyzes its oxidative dehydrogenation, which reduces NAD+ to NADH. Because β-HB is tied to the NAD+/NADH balance in ketone metabolism, it serves as a readout of energy metabolism and lipid metabolism.

Researchers measure β-HB as an index in diabetic ketoacidosis, where increased NADH production drives conversion of acetoacetic acid into β-HB. The source also states that β-HB level can be used as an index to evaluate glycosuria. The kit's listed research areas are metabolic diseases, glycolysis and lipid metabolism, and energy metabolism. Cited publications apply β-hydroxybutyrate measurement to osteoarthritis, where it is linked to chondrocyte mitophagy and cartilage degeneration, and to aging-related atrial fibrillation as a potential diagnostic biomarker.

The assay is a colorimetric, enzyme-coupled reaction. β-hydroxybutyrate dehydrogenase oxidizes β-HB and reduces NAD+ to NADH. A hydrogen transmitter then transfers electrons from NADH to WST-8, which forms a yellow product. The change in absorbance is read at 450 nm on a microplate reader (440-460 nm). In the procedure, 10 µL of standard or sample is mixed with 50 µL of enzyme reaction working solution and incubated at 37°C for 10 min. Then 160 µL of chromogenic working solution is added, and the plate is incubated at 37°C for 30 min before the OD is read at 450 nm.

The kit is intended for β-HB measurement in serum, plasma, urine, and animal tissue. The product page dilution table lists human serum and plasma, rat and mouse serum and plasma, 10% rat liver, kidney, and heart tissue homogenates, and human urine. Serum and plasma require ultrafiltration through a 50 kD tube, and turbid samples must be clarified by centrifugation first. Tissue is homogenized in cold PBS and processed the same way. Prepared samples are kept on ice until testing, and each well receives 10 µL of sample.

The analytical sensitivity is 0.01 mmol/L, determined by adding two standard deviations to the mean OD of the zero standard assayed 20 times. The detection range is 0.01-2.00 mmol/L. Intra-assay CV ranged from 1.7% to 2.3% for three human serum samples assayed in replicates of 20. Inter-assay CV ranged from 3.8% to 4.2% across 20 assays in duplicate by three operators. Mean recovery across high, middle, and low concentration samples was 105%, with individual recoveries of 104% to 106%. Standard curve data are provided for reference only, since OD values vary with operator, pipetting, and temperature.