100% Quality Guarantee
PhD-Level Technical Support
MAES0195 typical standard curve - Lactate dehydrogenase (LDH) Activity Assay Kit (WST-8)
Key Features

Lactate dehydrogenase (LDH) Activity Assay Kit (WST-8) (MAES0195)

SKU MAES0195
Product Type Assay
Instrument Microplate Reader
Sample Type Serum, Plasma, Animal Tissue, Hydrothorax, Cells
Sensitivity 0.11 U/L
Range 0.11-39.9 U/L
Assay Time 30 min
Shipping Gel Pack
Research Area Glycolysis & Carbohydrates
Research Area Enzyme Activity
Research Area Clinical Chemistry
€329

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

Lactate dehydrogenase (LDH) Activity Assay Kit (WST-8)

The Lactate Dehydrogenase (LDH) Activity Assay Kit (WST-8) (MAES0195) measures LDH enzymatic activity in serum, plasma, animal tissue, hydrothorax, cell and cell culture supernatant samples. LDH converts NAD+ to NADH, and the NADH is coupled to WST-8 reduction, producing a yellow product read at 450 nm. Researchers use extracellular LDH activity as a readout of cell damage and cell death.

Lactate dehydrogenase (LDH) is an oxidoreductase that catalyzes the conversion of lactate to pyruvic acid and back, converting NAD+ to NADH and back in the same reaction cycle. The enzyme is a tetramer of four subunits, and its two most common subunits are LDH-M and LDH-H. Because LDH links the lactate and pyruvate pool to the NAD+/NADH redox state, its activity reflects a central step of glycolysis and cellular energy metabolism.

LDH is released into the blood by cells after tissue damage or erythrocyte hemolysis, so extracellular LDH activity is used to detect cell damage or cell death. Researchers measure LDH in serum, plasma, hydrothorax, tissue homogenates, cells, and cell culture supernatant to assess injury and metabolic state. The product is listed for research in glycolysis and lipid metabolism, liver and renal function, and energy metabolism. Publications cited in the manual apply LDH-related readouts to pyroptosis in endometrial cancer, acute lung injury, and experimental autoimmune myasthenia gravis.

The kit uses a colorimetric method in which LDH catalyzes the reaction of lactic acid with NAD+ to produce pyruvic acid and NADH. Under the action of PMS, NADH transfers electrons to WST-8 to form a yellow product with a characteristic absorbance peak at 450 nm. The reaction working solution combines substrate, chromogenic agent, and coenzyme working solution. Standards and samples (50 µL each) are mixed with 50 µL of reaction working solution, incubated at 37°C for 10 minutes, stopped with 50 µL of stop solution, and read on a microplate reader at 450 nm.

The kit is validated for serum, plasma, animal tissue, cell culture supernatant, and cell samples. Serum and plasma are assayed directly, and if testing does not occur on the same day, they can be stored at -80°C for one month. Tissue is washed in cold PBS, homogenized in lysis solution at 4°C, and clarified by centrifugation, with the supernatant kept on ice. Cells are harvested, washed, and lysed in lysis solution on ice. Dilution factors differ by sample type, and any sample type not listed requires a pretest to confirm the dilution factor.

The detection range is 0.11 to 39.9 U/L, and the analytical sensitivity is 0.11 U/L, determined by adding two standard deviations to the mean OD of the zero standard assayed 20 times. Product data report an intra-assay CV of 2.3% and an inter-assay CV of 2.3%. The manual reports intra-assay CVs of 2.0 to 2.6% and inter-assay CVs of 2.0 to 2.5% across three human serum samples. The standard curve values are provided for reference only because OD readings vary with operator, pipetting technique, and temperature.