100% Quality Guarantee
PhD-Level Technical Support
beta-galactosidase (beta-GAL) Activity Assay Kit typical standard curve
Key Features

beta-galactosidase (beta-GAL) Activity Assay Kit (MAES0215)

SKU MAES0215
Product Type Assay
Instrument Microplate Reader
Detection Method Colorimetric
Sample Type Serum, Plasma, Cells, Animal And Plant Tissue
Sensitivity 16.19 U/L
Range 16.19-1200 U/L
Assay Time 70 min
€428

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

beta-galactosidase (beta-GAL) Activity Assay Kit

The β-galactosidase (β-GAL) Activity Assay Kit (MAES0215) measures β-GAL enzyme activity in cell lysates and animal and plant tissue homogenates. The assay uses a colorimetric readout: β-GAL hydrolyzes a nitrophenylgalactoside substrate to nitrophenol, which is quantified by absorbance at 400 nm. Researchers use the kit to compare β-GAL activity across samples in enzyme and protein studies. For Research Use Only.

β-galactosidase (β-GAL) is an enzyme that catalyzes the hydrolysis of lactose and glycosides. In plants, it is widely involved in growth and development and in the synthesis of plant cell walls. The enzyme can hydrolyze lactose from milk and whey into galactose and glucose. In the human body, β-galactosidase can also be used to treat lactose intolerance caused by lactose deficiency.

Researchers measure β-GAL activity to study its role in plant growth and cell wall synthesis, and to support biotechnology work in gene engineering, enzyme engineering, and protein engineering. This kit is intended to measure β-galactosidase activity in cells and in animal and plant tissue samples. The manual's example analysis reports activity in rat liver, spleen, lung, and heart tissue homogenates. The lactose intolerance context links the enzyme to human physiology, where lactose deficiency leads to intolerance.

The assay is colorimetric. β-GAL converts the substrate nitrophenylgalactoside pyranopyranoside to nitrophenol, which has a maximum absorption peak at 400 nm. Substrate working solution is prepared by dissolving the substrate powder in buffer solution in a 90-100°C water bath and cooling it to room temperature. Sample wells receive substrate working solution, while control and standard wells receive buffer solution. After activator is added, the plate is incubated at 37°C for 40 min, then chromogenic agent is added and the plate is incubated at 37°C for 10 min protected from light. Absorbance is read at 400 nm on a microplate reader set to 390-410 nm.

Suitable samples are cells (adherent or suspension) and animal or plant tissues. Tissues are washed in cold PBS (0.01 M, pH 7.4), homogenized in buffer solution at 4°C, and centrifuged at 10000×g for 10 min at 4°C to remove insoluble material. The supernatant is collected and kept on ice until testing. Buffer solution, activator agent, chromogenic agent, and the 20 mmol/L standard solution are stored at 2-8°C for 12 months, protected from light. Substrate powder is stored at -20°C for 12 months, and substrate working solution is stored at 2-8°C for 7 days protected from light. Because results are normalized to protein, the protein concentration of each supernatant must be determined separately.

The analytical sensitivity is 16.19 U/L, determined by adding two standard deviations to the mean OD of the zero standard assayed 20 times and calculating the corresponding concentration. The detection range is 16.19-1200 U/L. Intra-assay CV ranged from 2.8% to 3.2%, and inter-assay CV ranged from 5.6% to 6.3% across three human serum samples. Recovery across low, middle, and high standard concentrations averaged 101%, with individual recoveries of 99% to 103%.

View AllClose

0 Reviews

0
Based on 0 reviews

No reviews yet. Be the first to share your experience!

View AllClose