Description
Propidium Iodide (PI) Solution(750 µM)
Propidium Iodide (PI) Solution (750 µM) is a nucleic acid dye for identifying dead cells. PI enters cells that have lost membrane selective permeability, binds double-stranded DNA, and emits red fluorescence (Ex/Em 535/617 nm). It is used for fluorometric viability assessment by flow cytometry or fluorescence microscopy.
Propidium iodide (PI) is a nucleic acid dye whose staining depends on plasma membrane integrity. In living cells the membrane selectively limits what enters the cytoplasm and nucleus, so PI is largely excluded. When a cell dies and loses this selective permeability, PI can cross the membrane and bind double-stranded DNA. The reagent therefore reports membrane integrity at the level of individual cells rather than the abundance of a specific protein or pathway component.
Researchers use PI to separate dead cells from viable cells before downstream analysis, so that population-level measurements reflect intact cells. Flow cytometry and fluorescence microscopy are the two readouts described for this solution. When living cells must also be identified in the same sample, PI can be combined with Calcein AM Solution (100 µM), which labels living cells with green fluorescence, allowing live and dead cells to be distinguished side by side.
PI is excited at 535 nm and emits red fluorescence at 617 nm once bound to DNA. For flow cytometry, the 750 µM stock is diluted in PBS at 1 µL per 1 mL to form the staining working solution, and cells are resuspended in 200 µL of that solution. Incubation lasts 5 to 15 minutes at room temperature in the dark. For fluorescence microscopy, the working solution is prepared at 10 µL per 1 mL of PBS and incubated at 37°C for 10 to 30 minutes. Signal is read in the PE or PerCP/Cy5.5 channel on a flow cytometer, or with a TRITC filter set on a fluorescence microscope.
Suspended cells are collected and centrifuged at 300×g for 5 minutes, then washed once in PBS before staining. Adherent cells must first have their culture medium removed and be rinsed with PBS. Stained samples should be kept protected from light. If flow cytometry cannot be performed immediately, samples should be held at 4°C in the dark and analyzed within 2 hours. Wash buffers must be free of metal ions such as Mn2+, which quench fluorescence.
| Target: | Dead cells (loss of membrane selective permeability) |
| Dye type: | PI |
| Excitation/Emission: | 535 nm / 617 nm |
| Detection method: | Fluorometric; flow cytometry; fluorescence microscopy |
| Sample type: | Cells |
| Assay time: | 30 min |
| Use: | Research Use Only |
- Nucleic acid dye that stains cells with compromised membranes
- Red fluorescence, Ex/Em 535/617 nm
- Compatible with flow cytometry (PE or PerCP/Cy5.5 channel) and fluorescence microscopy (TRITC filter set)
- Staining time of about 30 min
- Supplied as a 750 µM solution; stored at -20°C for 12 months, protected from light
- Research Use Only
PI is excluded from cells with intact membranes. When membrane selective permeability is lost, PI enters the cell, intercalates with double-stranded DNA, and emits red fluorescence (Ex/Em 535/617 nm). Fluorescence is read by flow cytometry (PE or PerCP/Cy5.5 channel) or by fluorescence microscopy (TRITC filter set), with dead cells appearing as PI-positive.
- Discrimination of dead cells in flow cytometry viability assays
- Identification of dead cells by fluorescence microscopy
- Co-staining with Calcein AM to distinguish living and dead cell populations
- Cell death and cell viability studies in cultured cells
- PBS (pH 7.2-7.6)
- Centrifuge capable of 300×g
- Flow cytometer (PE or PerCP/Cy5.5 channel) or fluorescence microscope (TRITC filter set)
- 96-well or 24-well plates (for microscopy)
- Vortex mixer
- 37°C incubator (microscopy protocol) and 4°C refrigerator (flow cytometry hold)
- Calcein AM Solution (100 µM), optional for co-staining living cells
Cells in suspension (flow cytometry)
- Collect cells and centrifuge at 300×g for 5 min. Discard the supernatant.
- Add 1 mL of PBS to resuspend the cells, centrifuge at 300×g for 5 min, and discard the supernatant. Wash once.
- Thaw the PI Solution (750 µM) at room temperature and vortex-mix before use.
- Prepare the staining working solution at 1 µL PI Solution (750 µM) per 1 mL PBS (for example, 1 µL in 1 mL, 5 µL in 5 mL, or 10 µL in 10 mL PBS). Prepare according to the number of samples.
- Resuspend 1 to 5×10^5 cells in 200 µL of PI staining working solution.
- Incubate for 5 to 15 min at room temperature in the dark.
- Analyze directly by flow cytometry. If analysis is delayed, keep samples protected from light at 4°C and detect within 2 hours.
Adherent cells (fluorescence microscopy)
- Carefully remove the culture medium from adherent cells.
- Add an appropriate amount of PBS to each well to wash the cells, then repeat the wash and remove the PBS.
- Thaw the PI Solution (750 µM) at room temperature and vortex-mix before use.
- Prepare the staining working solution at 10 µL PI Solution (750 µM) per 1 mL PBS (for example, 10 µL in 1 mL, 50 µL in 5 mL, or 100 µL in 10 mL PBS).
- Add 100 µL of working solution per well of a 96-well plate, or 200 µL per well of a 24-well plate.
- Incubate at 37°C for 10 to 30 min.
- Observe under a fluorescence microscope after incubation.
Cells in suspension (fluorescence microscopy)
- Collect cells and centrifuge at 300×g for 5 min. Discard the supernatant and wash once with PBS as described above.
- Add PI staining working solution at 1 to 5×10^5 cells per 200 µL and incubate at room temperature.
- Add the cell suspension to a glass slide, cover gently with a coverslip, and observe under the microscope.
Flow cytometry
- Thaw the PI Solution (750 µM) at room temperature and vortex to mix.
- Prepare PI staining working solution at 1 µL PI Solution per 1 mL PBS (for 1 mL), 5 µL per 5 mL, or 10 µL per 10 mL.
- Collect cells and centrifuge at 300×g for 5 min. Discard the supernatant.
- Resuspend cells in 1 mL PBS, centrifuge at 300×g for 5 min, and discard the supernatant. Repeat wash once.
- Resuspend 1-5×105 cells in 200 µL of PI staining working solution and incubate for 5-15 min at room temperature in the dark.
- Analyze directly by flow cytometry. If analysis is delayed, keep samples protected from light at 4°C and detect within 2 hours.
Fluorescence microscopy
- Thaw the PI Solution (750 µM) at room temperature and vortex to mix.
- Prepare PI staining working solution at 10 µL PI Solution per 1 mL PBS, 50 µL per 5 mL, or 100 µL per 10 mL.
- Remove culture medium from adherent cells and wash with PBS. Remove the PBS.
- Add 100 µL of working solution per well of a 96-well plate, or 200 µL per well of a 24-well plate. Incubate at 37°C for 10-30 min.
- Observe under a fluorescence microscope using the TRITC filter set.
- For suspended cells, collect the cell pellet, add PI staining working solution at 1-5×105 cells per 200 µL, incubate at room temperature for 15-20 min, then mount on a glass slide and cover gently before observation.
Which sample types are supported?
The manual describes staining of cells, including cells in suspension for flow cytometry and suspended or adherent cells for fluorescence microscopy. Use 1 to 5×10^5 cells per 200 µL of working solution for suspension staining.
How should the PI Solution (750 µM) be stored?
Store at -20°C for 12 months, protected from light. Thaw at room temperature and vortex-mix before preparing the working solution.
Is there a quantitative measuring range, and what if samples cannot be run right away?
The manual does not define a quantitative measuring range; cell input is 1 to 5×10^5 cells per 200 µL. If flow cytometry cannot be performed immediately, protect samples from light, keep them at 4°C, and detect within 2 hours.
What are the key interference points?
Mn2+ has a fluorescence quenching effect, so wash buffers should not contain metal ions such as Mn2+. Excessive centrifuge acceleration and deceleration can cause cell loss, so use Acc ≤3 and Dec ≤2.
What instrument settings should be used?
PI is excited at 535 nm with emission at 617 nm. On a flow cytometer, use the PE or PerCP/Cy5.5 channel. On a fluorescence microscope, use a TRITC filter set.
How long does the assay take?
Flow cytometry staining incubation takes 5 to 15 min at room temperature in the dark. Fluorescence microscopy staining takes 10 to 30 min at 37°C.
| Storage: | -20°C, protected from light |
| Shelf life: | 12 months |
| Shipping: | Ice bag |
Cautions
- For research use only.
- Follow laboratory safety procedures for handling reagents.
- Store at the appropriate temperature to avoid loss of performance.
- Mn2+ quenches PI fluorescence; do not include Mn2+ or other metal ions in wash buffers.
- Excessive centrifuge acceleration and deceleration may cause cell loss. Use acceleration no more than 3 and deceleration no more than 2 (Acc ≤ 3, Dec ≤ 2).