Sodium (Na) Colorimetric Assay Kit (MAES0212)

SKU MAES0212
Product Type Assay
Instrument Microplate Reader
Detection Method Colorimetric
Sample Type Serum, Plasma, Tissue
Sensitivity 0.02 mmol/L
Range 0.02-20 mmol/L
Assay Time 15 min
€274

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

Sodium (Na) Colorimetric Assay Kit

The Sodium (Na) Colorimetric Assay Kit (MAES0212) quantifies sodium ion content in serum, plasma and tissue samples by a colorimetric, β-galactosidase-based method. Sodium ions activate the enzyme, and the resulting absorbance increase is read at 405 nm on a microplate reader. The kit is used in research workflows that require a quantitative, plate-based sodium measurement across a 0.02–20 mmol/L range. For research use only.

Sodium ion (Na+) is the target analyte of this kit, which measures sodium ion content in serum, plasma, and tissue samples. The product is listed under the research areas Inorganic Ions and Plant Physiology. For serum and plasma, sodium is reported as a concentration in mmol/L. For tissue samples, sodium is normalized to protein and reported as mmol/g protein, so the reported value depends on the sample type. The kit is for research use only and is not intended for clinical diagnosis.

Researchers use this kit in studies that link sodium content to physiological and disease models. The publications cited in the manual include a wearable sweat-analysis study, a study of hyperglycaemia-induced renal dysfunction in diet-induced prediabetic rats, and a study of salt tolerance in a plant regulated by a WRKY transcription factor. Other cited work examines stool-softening effects in water deficit-induced constipation in rats and cardiotoxicity induced by isoproterenol in Wistar rats. Together, these references span biofluid, renal, cardiac, gastrointestinal, and plant research.

The assay is a colorimetric method based on β-galactosidase activated by sodium ions. This enzyme catalyzes glycoside analogues to produce glycoside and o-nitrophenol. Sodium content is calculated indirectly from the increase in absorbance, which is read at 405 nm on a microplate reader. Each well receives 10 µL of blank, standard, or sample, followed by 80 µL of chromogenic agent and 120 µL of working solution. The first reading (A1) is taken, the plate is incubated at 37°C for 3 min, and a second reading (A2) is taken. The change in absorbance, ΔA = A2 − A1, is used for calculation.

Serum and plasma are assayed directly. If they are not assayed on the same day, they can be stored at -80°C for up to one month. Tissue samples are washed in cold PBS (0.01 M, pH 7.4) and homogenized at 4°C at 20 mg in 180 µL of double-distilled water. The homogenate is centrifuged at 10,000 × g for 10 min at 4°C, and the supernatant is kept on ice until assayed. Because sodium is high in these samples, sample dilution is required before testing. Protein concentration of the tissue supernatant must also be determined separately for normalization.

The analytical sensitivity is 0.02 mmol/L, and the detection range is 0.02-20 mmol/L. In the manual's precision study, intra-assay CV was 2.0-2.5% across three human serum samples assayed in replicates of 20. Inter-assay CV was 8.2-8.5% across 20 assays in duplicate by three operators. Mean recovery was 98% across high, middle, and low concentration samples, with individual recoveries of 94-101%. Results are based on the reagent, operator, and environmental conditions, so a consistent workflow is important for reproducibility.