CuZn/Mn Superoxide Dismutase (CuZn-SOD/Mn-SOD) Activity Assay Kit (Hydroxylamine) (MAES0035)

SKU MAES0035
Product Type Assay
Instrument Microplate Reader
Sample Type Serum, Plasma, Urine, Cells, Cell Culture Supernatant, Tissue
Sensitivity 1.35 U/mL
Range 1.35-62 U/mL
Assay Time 70 min
Shipping Gel Pack
Research Area Oxidative Stress
Research Area Reactive Oxygen Species
Research Area Plant & Environmental Stress
$652

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

CuZn/Mn Superoxide Dismutase (CuZn-SOD/Mn-SOD) Activity Assay Kit (Hydroxylamine)

The CuZn/Mn Superoxide Dismutase (CuZn-SOD/Mn-SOD) Activity Assay Kit (Hydroxylamine) (MAES0035) measures total SOD (T-SOD), CuZn-SOD and Mn-SOD activity in serum, plasma, urine, cells, cell culture supernatant and tissue homogenates. The kit uses a xanthine/xanthine oxidase superoxide-generating system and a colorimetric readout on a microplate reader. It is used in oxidative stress research to quantify SOD activity and to separate the CuZn-SOD and Mn-SOD contributions within a sample.

Superoxide dismutase (SOD) is an antioxidant enzyme system that acts on superoxide anion (O2•-). In higher animals, two forms of SOD are present in cells: copper-zinc SOD (CuZn-SOD) and manganese SOD (Mn-SOD). The sum of the two equals total SOD (T-SOD). Because the two isoforms respond differently to sample pretreatment, the kit reports T-SOD and CuZn-SOD activity directly, and Mn-SOD activity is calculated by subtraction.

SOD activity is measured as a readout of oxidative stress, which is the primary research area for this kit. The cited literature applies SOD measurements to ferroptosis and iron levels in the brain of 3×Tg-AD mice, lipid metabolism and inflammation in high-energy diet-induced hyperlipidemia rats, and TNF-α-induced inflammation in human nucleus pulposus cells. Other cited studies address cadmium chloride-induced apoptosis in HK-2 cells, deoxynivalenol-induced liver damage, and varicocele-associated male infertility.

The assay is colorimetric. Xanthine and xanthine oxidase generate superoxide anion, which oxidizes hydroxylamine to form nitrite. After a chromogenic reaction, nitrite produces a purplish red color. SOD in the sample inhibits superoxide anion and reduces nitrite formation, so the optical density (OD) falls relative to the control. In the procedure, the reaction mixture is incubated at 37°C for 50 min, chromogenic agent is added, and the mixture stands for 10 min at room temperature before OD is read at 550 nm on a microplate reader.

The kit is designed for serum, plasma, urine, animal tissue, plant tissue, cells, and cell culture supernatant. Serum and plasma are assayed directly. Urine is centrifuged at 10000 g for 15 min to remove insoluble material. Tissue and cell samples are homogenized in normal saline (0.9% NaCl) and centrifuged at 10000 × g for 10 min at 4°C, and their protein concentration must be determined separately so that activity can be normalized per mg of protein. Samples are kept on ice and must be diluted to fall within the optimal inhibition range.

Reported performance includes an analytical sensitivity of 1.35 U/mL and a detection range of 1.35-62 U/mL. The product page lists intra-assay CV of 5.1% and inter-assay CV of 9.6%. Replicate data in the manual show intra-assay CVs of 4.8-5.6% and inter-assay CVs of 9.2-10.2% across three human serum samples. Spike-recovery testing at low, middle, and high concentrations yielded recoveries of 98-101%, with an average recovery of 99%.