100% Quality Guarantee
PhD-Level Technical Support
MAES0012 typical standard curve - Glucose Uptake Fluorometric Assay Kit
Key Features

Glucose Uptake Fluorometric Assay Kit (MAES0012)

SKU MAES0012
Product Type Assay
Detection Method Fluorometric
Instrument Microplate Reader
Sample Type Cells
Sensitivity 0.02 nmol/uL
Range 0.02-0.5 nmol/uL
Assay Time 100 min
Shipping Gel Pack
Research Area Glycolysis & Carbohydrates
Research Area Glucose Uptake
Research Area Diabetes & Obesity
$1,596

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

Glucose Uptake Fluorometric Assay Kit

The Glucose Uptake Fluorometric Assay Kit (MAES0012) quantifies glucose uptake in cultured cell samples using the glucose analog 2-deoxyglucose (2-DG). Intracellular 2-DG-6-phosphate is detected through an NADPH-linked enzymatic reaction that generates a fluorescent product read at Ex/Em 530/590 nm. Researchers use the kit to study cell signaling and glucose metabolism by comparing uptake across experimental conditions.

The Glucose Uptake Fluorometric Assay Kit (MAES0012) measures glucose uptake in cell samples. It uses 2-deoxyglucose (2-DG), which cells take up and convert to 2-DG-6P. Glucose uptake content is reported in nmol/µL and is calculated from a standard curve prepared with known concentrations of a 0.3 nmol/µL standard. The readout therefore reflects the uptake and intracellular conversion of 2-DG in the cells being tested.

Researchers use the kit to quantify how much glucose cells take up under defined experimental conditions. The protocol includes a control well and a sample well for each condition, which allows uptake to be compared between untreated and treated cells. The kit is intended for measuring glucose uptake content in cell samples, and the manual's worked example applies the protocol to cultured 293T cells.

After uptake, 2-DG-6P is converted by glucose dehydrogenase to 6PDG, and NADP+ is reduced to NADPH. Diaphorase then uses NADPH to convert a probe into fluorescent substances. In the workflow, cells are incubated with 2-DG at 37°C for 30 min and washed, then treated with acid reagent for 10 min at room temperature and alkali reagent. A 30 µL aliquot from each standard, sample, or control well is transferred to a fluorescence well, and 170 µL of enzyme working solution is added. After a 30 min incubation at 37°C, fluorescence is read at an excitation wavelength of 530 nm and an emission wavelength of 590 nm.

Cells should be seeded at 20000-50000 cells per well in a 96-well plate and cultured or treated according to the experimental design. Before the uptake step, cells are starved overnight in serum-free medium, or for 6 to 8 hours, with attention to cell condition. The medium is then discarded, and cells are washed twice with 200 µL of KRPH solution containing 2% BSA. KRPH solution contains 20 mM Hepes, 5 mM KH2PO4, 1 mM MgSO4, 1 mM CaCl2, 136 mM NaCl, 4.7 mM KCl, 2% BSA, at pH 7.4. Kit reagents should be stored at -20°C and equilibrated to room temperature before use.

The manual gives a detection range of 0.02-0.3 nmol/µL. In the example analysis, the standard curve was y = 48152x + 521.17, and 293T cells (0.7×10^6 cells) gave a glucose uptake content of 0.093 nmol/µL. The manual states that standard curve values are provided for reference only, because fluorescence values vary with operator, pipetting technique, and temperature. Each standard curve should therefore be generated in the same run as the samples.