MDA Fluorometric Assay Kit (MAES0274)

SKU MAES0274
Product Type Assay
Instrument Fluorescence Microplate Reader
Detection Method Fluorometric
Sample Type Serum, Plasma, Animal Tissue, And Cell
Sensitivity 0.04 μmol/L
Range 0.04-10 μmol/L
$623

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

MDA Fluorometric Assay Kit

The MDA Fluorometric Assay Kit (MAES0274) quantifies malondialdehyde (MDA), a catabolite of lipid peroxides, in serum, plasma, animal tissue, and cell samples. MDA reacts with thiobarbituric acid (TBA) to form a red compound whose fluorescence is read at Ex/Em 520 nm/550 nm. Researchers use the kit to measure lipid peroxidation in oxidative stress studies.

Malondialdehyde (MDA) is a catabolite formed when lipid peroxides break down. Lipid peroxidation is an oxidative process in which reactive species attack lipids, and MDA is one of the products that accumulates from it. Because MDA is generated downstream of lipid peroxide degradation, it is used as an indicator of lipid peroxidation in biological samples. This kit is intended to quantify MDA content in serum, plasma, animal tissue, and cell samples.

Researchers measure MDA as an index of oxidative stress. Publications cited with this kit include studies of acute lung injury treated with an artificial exosome, colorectal cancer therapy that uses ferroptosis, and cerebral ischemia treated with reactive oxygen species-responsive nanoparticles. These contexts involve oxidative damage that is often assessed through lipid peroxidation endpoints, so MDA quantification supports comparison between treated and control groups.

The assay relies on the reaction of MDA with thiobarbituric acid (TBA) to form a red compound. The fluorescence intensity of this product is proportional to MDA content and is read at an excitation wavelength of 520 nm and an emission wavelength of 550 nm. Each standard or sample (0.1 mL) is combined with 0.1 mL of clarificant and 0.5 mL of chromogenic agent, which is a mixture of acid reagent and TBA reagent application solutions. Tubes are vortexed and incubated in a 95-100°C water bath for 40 min, cooled in running water, and centrifuged at 10000×g for 10 min. Then 0.25 mL of supernatant is transferred to a black microplate for reading.

Serum and plasma are tested directly. If testing does not occur on the same day, serum or plasma can be stored at -80°C for one month. Tissue samples are washed in cold PBS and homogenized at 4°C at an initial recommendation of 20 mg tissue per 180 µL PBS (0.01 M, pH 7.4). Cell samples are washed with PBS and lysed in CAMT lysis buffer, with an initial recommendation of 1×10^6 to 1×10^7 cells per 0.3 mL. Tissue and cell results are normalized to protein concentration, which must be measured separately. Lysate and homogenate supernatants are kept on ice until testing.

Reported analytical sensitivity is 0.04 µmol/L, and the detection range is 0.04-10 µmol/L. Intra-assay precision ranges from 2.3% to 4.3% CV, and inter-assay precision ranges from 4.5% to 7.0% CV. Recovery across high, middle, and low concentration samples averaged 97%, with individual values of 95%, 99%, and 97%. Standard curve data are provided for reference only, because fluorescence values vary with operator, pipetting technique, and temperature. A fresh set of standards should be prepared for each assay.