Description
Protein Carbonyl Colorimetric Assay Kit (Tissue And Serum Samples)
The Protein Carbonyl Colorimetric Assay Kit (Tissue And Serum Samples) (MAES0096) quantifies protein carbonyl content, a biological marker of ROS-mediated protein oxidation, in serum, plasma, tissue, hydrothorax, and cell culture supernatant samples. Carbonyl groups are derivatized with 2,4-dinitrophenylhydrazine (DNPH) to form a precipitate, which is washed, dissolved, and read at 370 nm on a microplate reader. The kit is used in oxidative stress research and in studies of amino acid and protein modification. For Research Use Only.
Reactive oxygen species (ROS) produced by aerobic metabolism can oxidize DNA, lipids, and proteins. Secondary reactions between amino acid side chains of proteins and lipid oxidation products are a main cause of protein carbonyl formation.
Protein carbonyl content is a biological marker of ROS-mediated protein oxidation and is used as an indicator of oxidative stress in research samples.
| Product Name: | Protein Carbonyl Colorimetric Assay Kit (Tissue And Serum Samples) |
| SKU: | MAES0096 |
| Size: | 96 Assays |
| Sample Types: | Serum, plasma, hydrothorax, cell culture supernatant, tissue |
| Detection Method: | Colorimetric |
| Wavelength: | 370 nm (instrument range 360-385 nm) |
| Instrument: | Microplate reader |
| Assay Time: | 140 min (2 h 20 min) |
| Research Area: | Oxidative stress; amino acids and proteins |
| Detection Method: | Colorimetric (DNPH-based) |
| Measurement Wavelength: | 370 nm |
| Instrument Wavelength Range: | 360-385 nm |
| Intra-assay CV: | 5.2% |
| Inter-assay CV: | 8.5% |
| Recommended Protein Concentration of Sample: | 1-10 mg/mL |
| Sample Volume per Reaction: | 0.1 mL |
| Assay Time: | 2 h 20 min |
- Colorimetric detection of protein carbonyl content, read at 370 nm (instrument range 360-385 nm)
- Validated sample types: serum, plasma, hydrothorax, cell culture supernatant, and tissue homogenate
- Total assay time of 140 min (2 h 20 min) on a microplate reader
- Intra-assay CV 5.2% and inter-assay CV 8.5%
- Includes all reagents for 96 assays; sold as 96 Assays only
- Storage at 2-8°C with a 12-month valid period
Protein carbonyl content increases after oxidation. Carbonyl groups react with 2,4-dinitrophenylhydrazine (DNPH) to form a reddish brown precipitate. After the precipitate is washed and dissolved, absorbance is measured at 370 nm. Carbonyl content is calculated indirectly using the formula: Protein carbonyl content (nmol/mg prot) = (A1 − A2) × 4.55 ÷ Cpr × f, where A1 is the sample OD, A2 is the control OD, Cpr is the sample protein concentration (mg prot/mL), and f is the pre-test dilution factor. The 4.55 constant incorporates the molar extinction coefficient of carbonyl (22000 L/mol/cm), the 0.8 cm optical path, the 1.25 mL total reaction volume, and the 0.1 mL sample volume.
- Quantification of protein carbonyl content as a marker of ROS-mediated protein oxidation
- Oxidative stress studies in serum, plasma, and hydrothorax samples
- Assessment of protein oxidation in tissue homogenates and cell culture supernatants
- Comparative studies of protein oxidation across experimental conditions in amino acid and protein research
| Component | Quantity | Storage |
| Homogenate Medium (Reagent1) | 50 mL × 2 vials | 2-8°C, 12 months |
| Sulfates Powder (Reagent2) | 2 vials | 2-8°C, 12 months, shading light |
| DNPH Solution (Reagent3) | 20 mL × 1 vial | 2-8°C, 12 months, shading light |
| Acid Reagent (Reagent4) | 20 mL × 1 vial | 2-8°C, 12 months |
| Protein Precipitator (Reagent5) | 60 mL × 1 vial | 2-8°C, 12 months |
| Denaturant (Reagent6) | 50 mL × 3 vials | 2-8°C, 12 months |
| Microplate | 96 wells | No requirement |
| Plate Sealer | 2 pieces | Not applicable |
| Sample Layout Sheet | 1 piece | Not applicable |
- Microplate reader capable of 360-385 nm (optimum 370 nm)
- Vortex mixer
- Micropipettor
- Water bath (37°C)
- Incubator (37°C)
- Centrifuge (13780 × g, 11580 × g, and 10000 × g capable; 4°C)
- Double-distilled water and deionized water
- Anhydrous ethanol
- Ethyl acetate
- PBS (0.01 M, pH 7.4) for tissue washing
- Round-bottom test tubes (recommended over tip-bottom tubes)
- 2 mL EP tubes
Reagent preparation
- Equilibrate all reagents to room temperature before use.
- Sulfates application solution: dissolve one vial of sulfates in 3 mL double-distilled water and mix well. Store at 2-8°C for up to 3 days, protected from light.
- Anhydrous ethanol-ethyl acetate mixture: for each tube, mix 500 µL anhydrous ethanol with 500 µL ethyl acetate (1000 µL total). Prepare on the day of use.