Description
Annexin V-EV500/PI Apoptosis Kit
The Annexin V-EV500/PI Apoptosis Kit (AKES048) is a fluorescent dual-staining reagent set for detecting apoptosis in cell samples. Annexin V conjugated to EV500 binds phosphatidylserine (PS) exposed on the outer leaflet of the apoptotic cell membrane, while propidium iodide (PI) marks cells that have lost membrane integrity. Researchers use the combination to distinguish early apoptotic, late apoptotic or necrotic, and PI-positive nuclei populations by flow cytometry or fluorescence microscopy.
Annexin V is a member of the annexin protein family that binds phosphatidylserine (PS) in a calcium-dependent manner. In this kit, Annexin V is conjugated to the EV500 dye, which allows it to bind specifically to PS on the outer leaflet of the apoptotic cell membrane. Because this binding marks cells undergoing apoptosis, the labeled protein serves as the primary apoptosis marker. Propidium iodide (PI), a nuclear dye, is supplied as the second stain and reports membrane integrity and DNA content.
Researchers use this Annexin V and PI combination to assess apoptosis in cell populations and to separate cells at different stages. Intact cells efficiently exclude PI, so PI entry indicates lost membrane integrity. Annexin V-positive, PI-negative cells are early apoptotic, cells positive for both markers are necrotic or late apoptotic, and PI-only positive events are naked nuclei. The kit is also suited to dead-cell discrimination and DNA analysis during flow cytometry. The manual demonstrates the kit with Jurkat cells treated with 5 µM camptothecin for 4 h.
Staining is performed in 1× Annexin V Binding Buffer on cell suspensions. Annexin V-EV500 and PI are added to each tube, the cells are mixed gently, and the tubes are incubated at room temperature for 15 to 20 min in the dark. EV500 has excitation and emission maxima of 425 and 500 nm and is detected in the Pacific Green channel, while PI is read in the ECD channel, which is preferred over PE. Results can be acquired by flow cytometry or fluorescence microscopy. The stated assay time is 40 min.
The kit is developed for both suspension and adherent cells. Cell input is 1 to 5 × 10^5 cells per tube, washed with PBS before resuspension in binding buffer. For adherent cultures, suspension cells generated after apoptosis induction must be collected and analyzed together with the adherent cells. Mechanical damage from digestion should be minimized, and EDTA-containing trypsin should be avoided because EDTA interferes with Annexin V binding to phosphatidylserine. Samples should be analyzed promptly after staining, and exposure to direct light should be limited to protect the fluorophores.
| Name: | Annexin V-EV500/PI Apoptosis Kit |
| SKU: | AKES048 |
| Pack Size: | 20 Assays, 100 Assays |
| Application: | Annexin V-based apoptosis detection |
| Detection Method: | Fluorometric; flow cytometry or fluorescence microscopy |
| Sample Type: | Cell samples (suspension and adherent cells) |
| Assay Time: | 15–20 min incubation at room temperature |
| Detection Instrument: | Flow cytometer or fluorescence microscope |
| Dye Type: | EV500 |
| Channel Set: | Pacific Green (Annexin V-EV500); ECD or PerCP/Cy5.5 (PI) |
- Annexin V-EV500 conjugate binds PS in a calcium-dependent manner
- PI co-staining distinguishes late apoptotic or necrotic cells from early apoptotic cells
- Compatible with suspension and adherent cell samples
- Pacific Green channel detection for Annexin V-EV500 on flow cytometers
- One-step and two-step staining protocols with a 15–20 min room-temperature incubation
- Research Use Only
Annexin V-EV500 binds specifically to PS exposed on the outer leaflet of apoptotic cell membranes. PI enters cells that have lost membrane integrity and stains DNA. Annexin V-EV500 single-positive cells are early apoptotic, Annexin V-EV500 and PI double-positive cells are necrotic or late apoptotic, and PI single-positive cells are naked nuclei. Signals are read by flow cytometry or fluorescence microscopy.
- Quantifying early and late apoptosis in cell populations by flow cytometry
- Discriminating dead cells from viable cells during flow cytometric analysis
- Classifying cells into early apoptotic, late apoptotic or necrotic, and naked nuclei populations
- Visualizing PS exposure in suspension and adherent cells by fluorescence microscopy
| Component | Quantity | Storage |
| Annexin V-EV500 Reagent | 20 Assays: 125 µL; 100 Assays: 500 µL | 2-8°C, protect from light |
| Annexin V Binding Buffer (10×) | 20 Assays: 1.4 mL × 2; 100 Assays: 5.5 mL × 2 | 2-8°C |
| PI Reagent (50 µg/mL) | 20 Assays: 125 µL; 100 Assays: 500 µL | 2-8°C, protect from light |
- PBS
- Deionized water
- Flow cytometer with a Pacific Green channel (or fluorescence microscope)
- Centrifuge capable of 300 ×g
- Microcentrifuge tubes or flow tubes
- Vortex mixer
- Trypsin solution without EDTA for adherent cells (EDTA interferes with Annexin V binding)
- Apoptosis-inducing reagents of interest
Cells, suspension
- Induce apoptosis with the reagents of interest. Collect the cell culture, centrifuge at 300 × g for 5 min, and discard the supernatant.
- Add PBS to wash the cells, resuspend gently, and count the cells.
- One-step process: aliquot 1 to 5 × 10^5 cells per tube, centrifuge at 300 × g for 5 min, discard the supernatant, wash with PBS, and discard the supernatant. Resuspend the cells in 500 µL of 1× Annexin V Binding Buffer.
- One-step process: add 5 µL of Annexin V-EV500 and 5 µL of PI to each tube.
- Two-step process: aliquot 1 to 5 × 10^5 cells per tube, centrifuge at 300 × g for 5 min, discard the supernatant, wash with PBS, and discard the supernatant. Resuspend the cells in 100 µL of 1× Annexin V Binding Buffer.
- Two-step process: add 2.5 µL of Annexin V-EV500 and 2.5 µL of PI to each tube. The manual notes that half the reagent amounts retain matched-quality results, and that reagent titration is recommended for specific models.
- Gently vortex the cells and incubate at room temperature for 15 to 20 min in the dark.
- Two-step process only: add 400 µL of 1× Annexin V Binding Buffer to each tube and mix gently.
- Analyze immediately with appropriate instrument settings. If analysis is delayed, place the cells on ice in the dark and analyze within 1 h.
- Prepare 1× Annexin V Binding Buffer by diluting Annexin V Binding Buffer (10×) with deionized water before use.
Cells, adherent
- Collect the suspension cells generated after apoptosis induction, and detect them together with the subsequently collected adherent cells.
- Minimize mechanical damage during digestion of adherent cells.
- Avoid EDTA-containing trypsin where possible. If EDTA-containing trypsin is used, wash the cells thoroughly after harvesting to remove EDTA.
- Following harvest, follow the suspension cell staining procedure above, beginning with the PBS wash and 1× Annexin V Binding Buffer resuspension.
One-step process
- Induce apoptosis in cells with the reagent of interest. Collect cells, centrifuge at 300 ×g for 5 min, and discard the supernatant. Wash with PBS, resuspend gently, and count cells.
- Aliquot 1–5×105 cells per tube, centrifuge at 300 ×g for 5 min, and discard the supernatant. Wash with PBS, discard the supernatant, and resuspend cells in 500 µL of 1× Annexin V Binding Buffer.
- Add 5 µL of Annexin V-EV500 and 5 µL of PI to each tube.
- Gently vortex and incubate at room temperature for 15–20 min in the dark.
- Analyze immediately. Otherwise, keep cells on ice in the dark and analyze within 1 h.
Two-step process
- Induce apoptosis in cells with the reagent of interest. Collect cells, centrifuge at 300 ×g for 5 min, and discard the supernatant. Wash with PBS, resuspend gently, and count cells.
- Aliquot 1–5×105 cells per tube, centrifuge at 300 ×g for 5 min, and discard the supernatant. Wash with PBS, discard the supernatant, and resuspend cells in 100 µL of 1× Annexin V Binding Buffer.
- Add 2.5 µL of Annexin V-EV500 and 2.5 µL of PI to each tube.
- Gently vortex and incubate at room temperature for 15–20 min in the dark.
- Add 400 µL of 1× Annexin V Binding Buffer to each tube and mix gently.
- Analyze immediately. Otherwise, keep cells on ice in the dark and analyze within 1 h.
Reagent preparation
- Prepare 1× Annexin V Binding Buffer by diluting 10× Annexin V Binding Buffer with deionized water before use.
What sample types and cell types can be used with this kit?
The kit is developed to detect apoptosis in suspension cells and adherent cells. Use 1 to 5 × 10^5 cells per tube. For adherent cells, collect the suspension cells generated after induction together with the adherent cells before analysis.
How should the kit and reagents be stored?
Store the kit at 2 to 8°C, protected from light. The manual states a shelf life of one year and advises avoiding freeze/thaw cycles, and the product page lists a 12-month expiration.
Does the kit need a titration step?
The manual recommends titrating the reagents for optimal performance in specific models. Half the reagent amounts in the two-step protocol can still give results of matched quality.
Which factors can interfere with staining?
EDTA in trypsin digestion solutions affects Annexin V binding to phosphatidylserine, so EDTA-containing trypsin should be avoided or thoroughly washed out. Extended light exposure can quench the fluorophores, and delays after staining can increase apoptosis or necrosis.
Which instrument channels should be used?
EV500 is detected in the Pacific Green channel with excitation and emission at 425 and 500 nm. PI is read in the ECD channel, which is preferred over PE. If the sample has FITC-channel autofluorescence, use the PerCP/Cy5.5 channel for PI.
How long does the assay take, and when should samples be analyzed?
The stated assay time is 40 min, including a 15 to 20 min room-temperature incubation in the dark. Analyze cells immediately after staining, or hold them on ice in the dark and analyze within 1 h.
| Storage: | 2–8°C, protect from light |
| Shelf Life: | 12 months |
| Handling: | Avoid freeze/thaw cycles |
| Shipping: | Ice bag |
Cautions
- For Research Use Only. Not for use in diagnostic or therapeutic procedures.
- Do not use trypsin containing EDTA; wash cells thoroughly after harvesting if EDTA-containing trypsin is used.
- When staining adherent cells, combine the floating cells collected after apoptosis induction with the harvested adherent cells.
- Minimize mechanical damage during adherent cell digestion.
- Protect stained samples from extended exposure to direct light to prevent fluorophore quenching.
- Analyze stained cells as soon as possible to limit changes in apoptosis or necrosis levels.
- Wear a lab coat and disposable gloves during the procedure.