100% Quality Guarantee
PhD-Level Technical Support
alpha-L-Fucosidase (AFU) Activity Assay Kit typical standard curve
Key Features

alpha-L-Fucosidase (AFU) Activity Assay Kit (MAES0244)

SKU MAES0244
Product Type Assay
Instrument Microplate Reader
Sample Type Serum, Plasma, Animal Tissue
Sensitivity 0.5 U/L
Range 0.5-80 U/L
Assay Time 70 min
€549

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

alpha-L-Fucosidase (AFU) Activity Assay Kit

The alpha-L-Fucosidase (AFU) Activity Assay Kit (MAES0244) measures AFU enzyme activity in serum, plasma, and animal tissue samples. The assay uses the colorless substrate nitrophenyl-α-L-fucoside, which AFU hydrolyzes to yellow nitrophenol, read at 405 nm. Researchers use it to quantify AFU activity in liver and renal function studies and in work on glycoprotein and glycolipid metabolism.

α-L-fucosidase (AFU) is an acid hydrolase found widely in organisms, including tissues, cells, blood, and body fluids. It participates in the metabolism of glycoproteins, glycolipids, and oligosaccharides by hydrolyzing α-L-fucosidic linkages. Through this activity, AFU is described as playing a key role in cell differentiation, apoptosis, inflammation, and host-pathogen interaction. Because its activity connects glycan turnover to these processes, measuring AFU activity provides a readout of enzyme function in a given biological sample.

Researchers measure AFU activity in the context of liver and renal function, the research area under which this kit is listed. AFU is present in serum, plasma, and animal tissues, so the kit supports comparative studies across human serum and rat or mouse plasma and tissue homogenates, including liver, spleen, and kidney. The sources link AFU to cell differentiation, apoptosis, inflammation, and host-pathogen interaction, so activity measurements can be used alongside organ-level studies of these processes. The kit is for research use only and is not intended for clinical diagnosis.

The assay is a colorimetric method. AFU hydrolyzes the colorless substrate nitrophenyl-α-L-fucoside to produce yellow nitrophenol, which has a significant absorption peak at 405 nm. Working solution (200 µL per well) is added to 20 µL of standard or sample in a microplate. After mixing, the plate is incubated at 37°C for 15 minutes and the first absorbance reading (A1) is taken at 405 nm. After a further 30 minutes at 37°C, a second reading (A2) is taken. The change in absorbance (ΔA = A2 − A1) correlates with nitrophenol content and is converted to activity using the standard curve. A microplate reader operating at 400–420 nm (optimum 405 nm) is required.

Validated sample types are serum, plasma, and animal tissue homogenates. Clarified serum is recommended, and hemolytic, hyperlipemic, and chylous samples are noted to affect results. Fresh samples are recommended for detection. Serum or plasma can be used directly, and if testing cannot be done the same day, it can be stored at −80°C for one month. Tissue samples are washed in cold PBS, homogenized in extraction solution, and centrifuged to remove insoluble material, with the supernatant kept on ice until testing. Because tissue activity is normalized to protein, the protein concentration of each supernatant must be determined separately.

Reported performance includes an analytical sensitivity of 0.5 U/L, determined as two standard deviations above the mean OD of 20 zero-standard replicates, and a detection range of 0.5–80 U/L. Intra-assay precision is 3.7% CV on the product page (3.5–4.0% across three human serum samples in the manual), and inter-assay precision is 8.4% CV (8.2–8.5% in the manual). Recovery across low, middle, and high standards averaged 97%, ranging from 96% to 98%. The total assay time is 1 h 10 min.