Description
One-step TUNEL Flow Cytometry Apoptosis Kit (Green, FITC)
The One-step TUNEL Flow Cytometry Apoptosis Kit (Green, FITC) (AKES109) detects apoptotic cells by labeling DNA strand breaks with FITC-labeled dUTP, catalyzed by terminal deoxynucleotidyl transferase (TdT). Labeled cells are quantified by flow cytometry in the FITC channel. The kit supports suspension and adherent cell samples and is intended for research use only.
Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) detects the DNA fragmentation that accompanies apoptosis. During apoptosis, specific DNA endonucleases are activated and cut genomic DNA between nucleosomes. The DNA of apoptotic cells is cleaved into multimers of 180~200 bp fragments, corresponding to the oligonucleosomal size, and typically migrates as a 180~200 bp ladder on an agarose gel. The exposed 3'-OH ends of these breaks serve as the substrate for the labeling reaction described below.
This One-step TUNEL Flow Cytometry Apoptosis Kit is designed to detect apoptosis in suspension cells and adherent cells by flow cytometry. Because the readout is single-cell and fluorescence-based, the kit allows the fraction of cells with DNA strand breaks to be quantified within a cell population. Researchers use this approach to assess apoptosis in experimental groups, with a negative control included in each experiment to confirm the specificity of the labeling reaction.
The exposed 3'-OH ends are labeled by terminal deoxynucleotidyl transferase (TdT) incorporating fluorescein-labeled dUTP. Cells are first fixed and permeabilized, then incubated with the TdT Equilibration Buffer, TdT Enzyme, and Labeling Solution as a freshly prepared Labeling Working Solution. The reaction proceeds at 37 °C for 60 min in the dark, with gentle mixing every 20 min. A Stop Solution is then added, followed by washing and resuspension in PBS (with 1% BSA). For this FITC-labeled version, the excitation and emission maxima are 490/530 nm, and the signal is read in the FITC channel of the flow cytometer.
Suspension and adherent cells are both supported. For adherent cells, some apoptotic cells detach and remain in the supernatant, so the supernatant must be collected together with the adherent fraction. Cells should be processed promptly, and the minimum number of cells per assay is 5×10^5. Labeling Solution and TdT Enzyme should not be vortexed and should be protected from freezing and thawing. Fluorescence can be quenched easily, so samples should be analyzed as soon as possible after staining.
| Product name: | One-step TUNEL Flow Cytometry Apoptosis Kit (Green, FITC) |
| SKU: | AKES109 |
| Detection method: | Fluorometric, flow cytometry |
| Sample type: | Cells (suspension and adherent) |
| Assay time: | 2.5-3 hours |
| Detection instrument: | Flow cytometer |
| Dye: | FITC |
| Excitation/Emission: | 490/530 nm |
| Flow cytometer channel: | FITC |
- Fluorometric TUNEL labeling of apoptotic DNA 3'-OH ends with FITC-labeled dUTP
- Detection by flow cytometry in the FITC channel (Ex/Em 490/530 nm)
- Compatible with suspension and adherent cells
- Assay time of 2.5-3 hours
- Includes TdT enzyme, equilibration buffer, labeling solution, fixation and permeabilization buffers, and stop solution
When cells undergo apoptosis, specific DNA endonucleases are activated and cut genomic DNA between nucleosomes. After fixation and permeabilization, the exposed 3'-OH ends of the broken DNA are labeled by TdT with FITC-labeled dUTP. Labeled cells are then detected by flow cytometry in the FITC channel (Ex/Em 490/530 nm).
- Quantification of apoptotic cells in suspension cell cultures by flow cytometry
- Detection of apoptosis in adherent cell cultures, including detached cells in the supernatant when collected
- Assessment of apoptosis induction by drug or compound treatments, using camptothecin-treated HL-60 cells as a validation model
- Inclusion of TdT-free negative controls to evaluate TUNEL labeling specificity
| Component | Quantity | Storage |
| TdT Equilibration Buffer | Included | -20°C |
| TdT Enzyme | Included | -20°C |
| Labeling Solution (FITC) | Included | -20°C, protect from light |
| Fixation Buffer | Included | -20°C |
| Permeabilization Buffer | Included | -20°C |
| Stop Solution | Included | -20°C |
- PBS buffer with 1% BSA, pH 7.2-7.4
- PBS with 1% saponin, pH 7.2-7.6
- 4% paraformaldehyde dissolved in PBS
- Deionized water
- Flow cytometer with FITC channel
- Centrifuge (600×g and 300×g capable)
- Incubator or water bath at 37°C
- Ice
- Micropipettes and sterile tubes
Suspension cells
- Collect the cells and count them. Take 1×10^6 cells, centrifuge at 300×g for 5 min, and discard the supernatant.
- Add 200 µL of PBS (with 1% BSA) to resuspend the cells, add 200 µL of Fixation Buffer, and incubate at room temperature for 60 min, mixing every 15 min.
- Add 1 mL of PBS (with 1% BSA), centrifuge at 600×g for 5 min, and discard the supernatant.
- Add 200 µL of Permeabilization Buffer and incubate on ice for 10 min. Thaw the Permeabilization Buffer and place it at 4 °C before use. The maximum permeabilization time should not exceed 15 min.
- Add 1~2 mL of PBS (with 1% BSA) to stop the reaction, mix by gently pipetting, centrifuge at 600×g for 5 min, and discard the supernatant.
- Add 200 µL of TdT Equilibration Buffer, mix by gently pipetting, and incubate at 37 °C for 15 min.
- Centrifuge at 600×g for 5 min, discard the supernatant, and collect the cell pellet.
- Prepare 100 µL of Labeling Working Solution per sample, using fresh solution prepared before use. Typical per-sample composition: TdT Equilibration Buffer 70 µL, Labeling Solution 20 µL, and TdT Enzyme 10 µL. For the negative control, omit the TdT Enzyme: TdT Equilibration Buffer 80 µL and Labeling Solution 20 µL.
- Gently pipette the Labeling Working Solution into the cell pellet to incorporate the TdT Enzyme. Do not vortex. Incubate at 37 °C for 60 min in the dark, mixing gently every 20 min.
- Add 1 mL of Stop Solution, mix gently by pipetting, and incubate at room temperature for 5 min. Add 300~500 µL of PBS (with 1% BSA), centrifuge at 600×g for 5 min, and discard the supernatant.
- Add 200 µL of PBS (with 1% BSA) to resuspend the cells by gently pipetting 10~20 times, and analyze by flow cytometry.
Adherent cells
- Collect the culture supernatant first. Some apoptotic cells are suspended in the supernatant, and these cells should also be collected.
- Detach and count the adherent cells, then combine them with the supernatant fraction. Take 1×10^6 cells, centrifuge at 300×g for 5 min, and discard the supernatant.
- Continue with the same fixation, permeabilization, TdT equilibration, labeling, stop, and washing steps described for suspension cells.
- Use 100 µL of freshly prepared Labeling Working Solution per sample, with the TdT Enzyme omitted for the negative control.
Cell preparation and fixation
- Count cells and take 1×106 cells per sample. Centrifuge at 300×g for 5 min and discard the supernatant. For adherent cells, collect the detached apoptotic cells in the supernatant as well.
- Resuspend cells in 200 µL PBS (with 1% BSA). Add 200 µL Fixation Buffer and incubate at room temperature for 60 min, mixing every 15 min.
- Add 1 mL PBS (with 1% BSA), centrifuge at 600×g for 5 min, and discard the supernatant.
Permeabilization and TdT equilibration
- Add 200 µL Permeabilization Buffer (thawed and kept at 4°C before use) and incubate on ice for 10 min. Do not exceed 15 min.
- Add 1-2 mL PBS (with 1% BSA) to stop the reaction, mix gently, centrifuge at 600×g for 5 min, and discard the supernatant.
- Add 200 µL TdT Equilibration Buffer, mix gently, and incubate at 37°C for 15 min.
- Centrifuge at 600×g for 5 min, discard the supernatant, and collect the cell pellet.
Labeling and detection
- Prepare fresh Labeling Working Solution (100 µL per sample) as follows: experimental group, 70 µL TdT Equilibration Buffer, 20 µL Labeling Solution, and 10 µL TdT Enzyme. For the negative control, use 80 µL TdT Equilibration Buffer, 20 µL Labeling Solution, and no TdT Enzyme.
- Gently pipette the Labeling Working Solution onto the cell pellet and incubate at 37°C for 60 min in the dark, mixing gently every 20 min.
- Add 1 mL Stop Solution, mix gently, and incubate at room temperature for 5 min. Add 300-500 µL PBS (with 1% BSA), centrifuge at 600×g for 5 min, and discard the supernatant.
- Resuspend cells in 200 µL PBS (with 1% BSA) and analyze by flow cytometry in the FITC channel.
What is the minimum number of cells required per assay?
The minimum number of cells for this kit should not be less than 5×10^5. The protocol uses 1×10^6 cells per sample as the starting number.
How should the kit and its components be stored?
The kit can be stored at -20 °C for 12 months and should be protected from light. The Labeling Solution should be stored in the dark, and it is recommended to aliquot it to avoid freeze-thaw cycles. TdT Enzyme must be stored strictly at -20 °C and returned to -20 °C immediately after use.
What should I do if no apoptotic cell population is detected?
If no apoptotic population is detected, the cells may not have been induced to undergo apoptosis. Set up different concentration gradients and induction times to find suitable induction conditions. Include a negative control without TdT Enzyme in each experiment.
Which flow cytometer settings should be used?
Select the FITC channel for detection, with excitation and emission at 490/530 nm and a FITC filter set. The kit requires a flow cytometer and a centrifuge.
What can cause poor results during permeabilization?
Excess cellular debris can result from insufficient fixation or from permeabilization that is too long or at too high a temperature. Keep permeabilization between 10 and 15 min on ice, and do not exceed 15 min. Wash cells with a buffer that does not contain chelating agents such as EDTA, because EDTA can make the TdT enzyme ineffective.
How long does the assay take?
The assay time is 2.5 to 3 hours.
| Storage temperature: | -20°C |
| Storage duration: | 12 months |
| Light sensitivity: | Store in the dark (protect from light) |
| Expiration: | 12 months |
| Shipping: | Ice bag |
Cautions
- For research use only. Not for use in diagnostic or therapeutic procedures.
- The minimum number of cells for this kit is 5×105.
- Include a negative control (TdT Enzyme omitted) in each experiment to demonstrate TUNEL specificity.
- Do not vortex the Labeling Solution or TdT Enzyme. Avoid freezing and thawing cycles; aliquot reagents into smaller volumes.
- Keep TdT Enzyme strictly at -20°C. Return it to -20°C immediately after use.
- Do not use buffers containing chelating agents such as EDTA, which render TdT ineffective.
- If permeabilization is too long or too warm, cells may break. Keep Permeabilization Buffer on ice and limit permeabilization to 15 min.
- Insufficient fixation can lead to cell debris. Ensure full fixation before permeabilization.
- Detect samples as soon as possible to avoid rapid fluorescence quenching.
- When resuspending cells, pipette gently 10-20 times to avoid cell damage and bubbles.