100% Quality Guarantee
PhD-Level Technical Support
Key Features

One-step TUNEL Flow Cytometry Apoptosis Kit (Red, AF555) (AKES114)

SKU AKES114
€329

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

One-step TUNEL Flow Cytometry Apoptosis Kit (Red, AF555)

The One-step TUNEL Flow Cytometry Apoptosis Kit (Red, AF555) labels the exposed 3'-OH ends of fragmented genomic DNA with fluorescein-labeled dUTP using Terminal Deoxynucleotidyl Transferase (TdT). Labeled apoptotic cells are quantified by flow cytometry. Researchers use the kit to detect apoptosis in suspension and adherent cell samples with a fast, simple workflow of about 2.5-3 hours.

Apoptosis is programmed cell death. During apoptosis, specific DNA endonucleases are activated and cut genomic DNA between nucleosomes. The DNA of apoptotic cells is cleaved into multimers of 180~200 bp fragments, corresponding to the oligonucleosomal size, and typically migrates as a ladder of 180~200 bp on an agarose gel. The breaks expose 3'-OH ends on the fragmented DNA, and these free 3'-OH ends are the substrate this kit detects.

Researchers use this kit to detect apoptosis in both suspension and adherent cell populations by flow cytometry. Because the readout is per cell, the kit supports quantification of the apoptotic fraction within a population rather than only a bulk DNA ladder. The manual recommends setting up a negative control in each experiment to show the objectivity and accuracy of the TUNEL reaction. Where apoptosis is not induced, the manual advises testing different concentration gradients and induction times to find suitable induction conditions. The validation data use HL-60 cells treated with camptothecin as a positive apoptosis model.

The assay uses a one-step TUNEL labeling reaction. Terdeoxynucleotidyl Transferase (TdT) catalyzes the addition of a fluorescent dUTP label to the exposed 3'-OH ends. The label is AF555 (excitation/emission 555/565 nm), and it is read on the PE/PE-TR channel of a flow cytometer. Cells are fixed, permeabilized, equilibrated, and then incubated with the TdT labeling working solution at 37 °C for 60 min in the dark. Following a stop reaction and washes, cells are resuspended in PBS with 1% BSA and analyzed. The total assay time is 2.5 to 3 hours.

The kit is for research use only. It is validated for cells, including suspension cells and adherent cells, and the manual requires a minimum of 5×10^5 cells per sample. Samples should be processed promptly because the fluorescence is easily quenched. For adherent cultures, some apoptotic cells detach into the supernatant, so the supernatant must be collected together with the adherent cells. Using PBS with 1% BSA during resuspension and washing reduces cell loss during centrifugation. Permeabilization must be kept short and cold to avoid cell breakage.

View AllClose

0 Reviews

0
Based on 0 reviews

No reviews yet. Be the first to share your experience!

View AllClose