1-Step TUNEL Assays

1-Step TUNEL Assays

Cell Health & Death

1-Step TUNEL assay kits

Label the DNA strand breaks of late-stage apoptosis with a single buffer-and-enzyme mix. Fluorescent kits for in situ imaging and flow cytometry, plus an HRP-DAB kit for light microscopy.

In situ & flow cytometryFITC to far-redHRP-DAB option
In this category

Three TUNEL formats

In situ fluorescence

TUNEL 1-Step In Situ kits in FITC, FL488, FL555, FL594 and FL647 for fixed cells and tissue sections.

Flow cytometry

One-step TUNEL flow cytometry kits in green, red and violet channels to quantify apoptotic cells across a population.

HRP-DAB colorimetric

A chromogenic kit for light microscopy when fluorescence imaging is not available.

Choosing a kit

Fluorophore selection guide

TUNEL (terminal deoxynucleotidyl transferase dUTP nick end labelling) detects DNA fragmentation, a hallmark of late-stage apoptosis. The enzyme tags the exposed 3′-OH ends of fragmented DNA with a fluorophore or chromogen so that apoptotic nuclei can be seen and counted.

Match the kit to your instrument and to any autofluorescence in the sample.

  • No autofluorescence, or red only: choose FITC or FL488 (green)
  • Green autofluorescence: choose FL555 or FL594 (red)
  • Both red and green autofluorescence: choose FL647 (far-red)
  • No fluorescence equipment: choose the HRP-DAB kit
Workflow

How the 1-Step TUNEL assay works

1

React in one step

Add the single buffer-and-enzyme mix to fixed cells or sections.

2

Label the DNA breaks

Terminal transferase tags fragmented DNA with the chosen fluorophore or HRP-DAB reporter.

3

Read the result

Visualise by fluorescence or confocal microscopy, flow cytometry or light microscopy.

FAQs

TUNEL assay FAQs

What does the TUNEL assay detect?

DNA fragmentation, a hallmark of late-stage apoptosis. Labelled nucleotides are added to the 3′-OH ends of broken DNA so apoptotic nuclei can be counted.

What makes these kits 1-Step?

They use a single buffer-and-enzyme mix, so there is no need to prepare two separate reactions. That shortens the protocol and reduces variability.

What is the difference between FITC and FL488?

Both emit green fluorescence at similar wavelengths, but FL488 resists fading better, which helps when the signal needs to be viewed for longer.

Which samples are compatible?

Cells and tissues fixed in situ, including paraffin-embedded sections. Flow cytometry kits are used with cell suspensions.