Triglyceride Fluorometric Assay Kit (MAES0257)

SKU MAES0257
Product Type Assay
Instrument Fluorescence Microplate Reader
Detection Method Fluorometric
Sample Type Serum, Plasma, Tissue And Cell Sample
Sensitivity 0.8 μmol/L
Range 0.8-30 μmol/L
Assay Time 15 min
$942

Request a formal quotation

A PDF quote with its own quote number, ready for your purchasing office to raise a PO against. Back within 4 working hours, from a PhD scientist — not an autoresponder.

  • PO-ready PDFQuote number, VAT, Incoterms
  • Volume pricing appliedDiscounts from 2 kits up
  • Valid 30 daysPrices held while you get sign-off
Anything we should know? optional

No account needed. We use your details only to prepare and send this quote. If it's urgent, say so in the box and we'll come back the same working day.

Global Shipping: 80+ Countries
White Glove Service: Available upon request
Batch Consistency: Contact Sales
Distributors: 60+ Countries

Description

system_update_altDatasheetsystem_update_altMSDS

Triglyceride Fluorometric Assay Kit

The Assay Genie Triglyceride Fluorometric Assay Kit (MAES0257) quantifies triglyceride (TG) in serum, plasma, tissue and cell samples. TG is converted by enzymes to hydrolytic products, which are then catalyzed to fluorescent substances read at Ex/Em 535/587 nm. Researchers use the kit for lipid and energy metabolism studies where TG must be measured in small sample volumes. The kit is for Research Use Only.

Triglyceride (TG) is the analyte measured by this kit, and the product is listed under the glycolysis and lipid metabolism and energy metabolism research areas. The kit quantifies TG content in serum, plasma, tissue, and cell samples. Results are reported in mmol/L for serum and plasma and in µmol/g protein for tissue and cell lysates, so the unit depends on the sample type. The assay is also known by the synonym TG. The kit is labeled for research use only and is not intended for clinical diagnosis.

Researchers measure triglyceride to study lipid and energy metabolism. The sources describe use across several physiology models: porcine heart and liver tissue homogenates, CHO and 293T cells, and human and mouse serum. Comparing TG content across these matrices allows investigators to examine lipid handling in different tissues, cell lines, and species. The manual states that the kit is intended for determining triglyceride in serum, plasma, tissue, and cell samples, and it must be used for research purposes only.

The assay is enzymatic and fluorometric. Triglyceride is converted by enzymes into hydrolytic products, which are then catalyzed by enzymes to produce fluorescent substances. For each well, a 200 µL chromogenic working solution is prepared on the day of use by mixing 196 µL of Enzyme Working Solution with 4 µL of Probe, and it must be protected from light. Then 20 µL of standard or sample is added to the appropriate well, followed by 200 µL of working solution. After mixing, the plate is incubated at 37°C for 5 min. Fluorescence is read at an excitation wavelength of 535 nm and an emission wavelength of 587 nm.

Serum and plasma can be assayed directly without extraction. Tissue and cell samples are homogenized in extraction solution, clarified by centrifugation at 10000 × g for 10 min, and the supernatant is kept on ice until assayed. Tissue homogenization uses 20 mg of tissue in 180 µL extraction solution at 4°C. Cell homogenization uses 1 × 10^6 cells in 200 µL extraction solution with an ultrasonic cell disruptor at 4°C. The protein concentration of each supernatant must be determined separately so that tissue and cell results can be normalized.

Reported performance includes an analytical sensitivity of 0.8 µmol/L and a detection range of 0.8 to 30 µmol/L. In the manual's replicate study, intra-assay precision ranged from 3.7% to 4.2% CV and inter-assay precision ranged from 8.4% to 10.0% CV. Mean recovery was 105%, with individual recoveries of 103% to 107% across three spiked concentrations. The kit specifications give an intra-assay CV of 3.9% and an inter-assay CV of 9.1%.