10877 results for 'prg 1 look'
-
Unlocking a New Immune Checkpoint: The CD47-Thrombospondin-1 Pathway in Cancer(Post)
Cancer immunotherapy has revolutionized oncology, offering powerful new ways to treat various malignancies by harnessing the body's own immune system. Central to this success are immune checkpoint inh
Dual PD-1/PD-L2 Blockade: Expanding the Horizons of Cancer Immunotherapy(Post)Introduction to PD-1, PD-L1, and PD-L2 in Cancer ImmunotherapyThe PD-1/PD-L1 immune checkpoint pathway has been instrumental in cancer immunotherapy, with PD-1 (programmed death-1) inhibi
PD-1 PD-L1 Pathway Diagram(Page) Co-Inhibitory Checkpoints Beyond PD-1: CTLA-4, LAG-3 and TIM-3(Post)PD-1 gets the attention, but it is one brake among many — and the others do not work the same way. The co-inhibitory receptors are routinely drawn as interchangeable stop signs on a T cell. They are
TIGIT/DNAM-1/CD155 (PVR) Checkpoint Axis(Page) Kompetitiver ELISA im Labor: Startwerte 1–10 µg/mL, Fehlerbehebung(Post)Ein kompetitiver ELISA misst Analytkonzentrationen über ein invertiertes Signal: Probeantigen und ein markierter Tracer konkurrieren um dieselben, begrenzten Bindungsstellen. Je mehr Analyt in der
LPS ELISA Troubleshooting: The Importance of Sample Nature(Post)Quick answer A researcher measuring circulating lipopolysaccharide (LPS) in human serum with our LPS ELISA saw almost no color, even after 30 minutes with substrate. Samples had been test
Adhesion molecules in atherosclerosis – ICAM1(Post)Adhesion Molecules Direct cell-cell interactions are maintained and regulated by cell adhesion molecules. The expression of adhesion molecules
TMB Incubation Time in ELISA: Why It Makes or Breaks Results(Post)Quick answer A researcher ran a high-sensitivity porcine insulin sandwich ELISA on EDTA plasma and saw main-run duplicate CVs as high as 29.6% (kit spec: intra-assay CV <8%) togethe
Sci-Hub: Your Proxy to Unrestricted Knowledge(Post)Introduction to Sci-Hub In the realm of science and academia, one name has been echoing in every corner of the globe, Sci-Hub. Created by Alexandra Elbakyan, a Kazakhstani computer scientist
One Integrin Chain, Two Partners, Brain or Gut(Post)A chemokine gradient does not move a leukocyte anywhere. It only tells one that has already stopped which way to go. That sentence is the whole map. Trafficking is a four-step cascade and the steps a
Your Th2 Phenotype Might Not Be a T Cell(Post)If your knockout showed a type 2 phenotype and you attributed it to Th2 cells, there is a reasonable chance you were looking at something else. Innate lymphoid cells run T-bet, GATA3 and RORγt — not
8-OHdG/Creatinine Ratio Too High? Urine ELISA Troubleshooting(Post)Quick answer A researcher running an 8-OHdG ELISA and a creatinine ELISA on human urine got 8-OHdG/creatinine ratios in the hundreds, then the thousands, of ng/mg, far above the ~30–40
Glucose Assay Saliva Troubleshooting: Fixing Low Readings(Post)Quick answer A researcher measuring glucose in human saliva on the fluorometric procedure of a glucose assay kit had a textbook standard curve, yet every sample read far below the expe
Anti-Angiogenics Do Not Starve Tumours. They Open Them.(Post)Anti-angiogenic therapy does not work by starving tumours, and the trials that assumed it did are the reason the field spent a decade disappointed. Cutting off the blood supply was the original pitch
T-Cell Engagers and Bispecific Antibodies(Page) ELISA Troubleshooting: A Low Standard Curve and Samples Reading Off-Scale(Post)Quick answer On the Periaxin (PRX) ELISA, a researcher found every serum sample reading above the top standard — optical density (OD) around 2.8–3.0 at 450 nm, well beyond the highest
T-Cell Co-Stimulation and Agonist Checkpoint Signalling Explained(Post)Signal 1 tells a T cell what it is looking at; signal 2 tells it whether to care. The same peptide–MHC engagement that launches a productive effector response can just as easily install an anergy pro
Distributors(Page) In Vivo Functional Grade Antibodies(Page)Featured
Human CAT (Catalase) ELISA Kit (HUFI07676)
- Product Code:
- HUFI07676
- Detection Method:
- Sandwich ELISA, Double Antibody
- Sensitivity:
- 9.375 pg/mL
- Range:
- 15.625-1000 pg/mL
Human MICA ELISA Kit (HUFI00015)
- Product Code:
- HUFI00015
- Detection Method:
- Sandwich ELISA, Double Antibody
- Sensitivity:
- 46.875 pg/mL
- Range:
- 78.125-5000 pg/mL
Fatty Acid Oxidation (FAO) Assay Kit (BR00001)
- Product Code:
- BR00001
- Instrument:
- Microplate Reader
Anti-Mouse IFNAR-1 In Vivo Antibody - Low Endotoxin (IVMB0202)
- Product Code:
- IVMB0202
- Antibody Type:
- Functional-Grade In Vivo Antibody
- Clone:
- MAR1-5A3
- Protein:
- IFNAR1
- Isotype:
- Mouse IgG1
Anti-Mouse CD25 In Vivo Antibody - Low Endotoxin (IVMB0148)
- Product Code:
- IVMB0148
- Antibody Type:
- Functional-Grade In Vivo Antibody
- Clone:
- PC61
- Protein:
- CD25
- Isotype:
- Rat IgG1 lambda
Anti-Mouse NK1.1 In Vivo Antibody - Low Endotoxin (IVMB0100)
- Product Code:
- IVMB0100
- Antibody Type:
- Functional-Grade In Vivo Antibody
- Clone:
- PK136
- Protein:
- NK1.1
- Isotype:
- Mouse IgG2a kappa
Anti-Mouse PD-1 Antibody [RMP1-14] In Vivo-Low Endotoxin (IVMB0037)
- Product Code:
- IVMB0037
- Antibody Type:
- Functional-Grade In Vivo Antibody
- Clone:
- RMP1-14
- Protein:
- PD-1
- Isotype:
- Rat IgG2a kappa
LSAMP Rabbit Polyclonal Antibody (CAB14248)
- Product Code:
- CAB14248
- Antibody Type:
- Polyclonal Antibody
MCM4 Rabbit Polyclonal Antibody (CAB13513)
- Product Code:
- CAB13513
- Antibody Type:
- Polyclonal Antibody
VEGF Rabbit Polyclonal Antibody (CAB12303)
- Product Code:
- CAB12303
- Antibody Type:
- Polyclonal Antibody
MDA ELISA Kit (UNFI0048)
- Product Code:
- UNFI0048
- Detection Method:
- Competitive ELISA, Coated with Antigen
- Sensitivity:
- 4.688 ng/mL
- Range:
- 7.813-500 ng/mL
Dopamine ELISA Kit (UNFI0013)
- Product Code:
- UNFI0013
- Detection Method:
- Competitive ELISA, Coated with Antigen
- Sensitivity:
- 0.938 ng/mL
- Range:
- 1.563-100 ng/mL
Serotonin ELISA Kit (UNFI0018)
- Product Code:
- UNFI0018
- Detection Method:
- Competitive ELISA, Coated with Antigen
- Sensitivity:
- 0.938 ng/mL
- Range:
- 1.563-100 ng/mL
PGE2 ELISA Kit (UNFI0032)
- Product Code:
- UNFI0032
- Detection Method:
- Competitive ELISA, Coated with Antigen
- Sensitivity:
- 18.75 pg/mL
- Range:
- 31.25-2000 pg/mL
Human IL-6 ELISA Kit (HUFI00180)
- Product Code:
- HUFI00180
- Sensitivity:
- 2.813pg/ml
- Range:
- 4.688-300pg/ml
- ELISA Type:
- Sandwich
Glucose Assay Kit (BA0081)
- Product Code:
- BA0081
- Instrument:
- Microplate Reader