null

Anti-Infliximab (Remsima®)ADA Qualitative ELISA Kit

SKU:
HUMB00006
Product Type:
ELISA Kit
ELISA Type:
Biosimilar ELISA
Biosimilar ELISA Type:
Qualitative
Applications:
ELISA
Reactivity:
Human
Analytes:
Infliximab (Remsima®)
Research Area:
Anti-TNF Alpha
$1,223
Frequently bought together:

Description

system_update_altDatasheet

Anti-Infliximab ADA Qualitative ELISA Kit

Enzyme-linked immunosorbent assay for the quantitative determination of antibodies to infliximab Remsima® in serum and plasma. Remsima® the world's first biosimilar mAb (approved in 2013 by EMA). The Committee for Medicinal Products for Human Use (CHMP) decided that, in accordance with EU requirements, Remsima® has been shown to have a comparable quality, safety and efficacy profile to Remicade. Infliximab (Remsima®) has been associated with the development of anti-infliximab antibodies, even some were reported to be neutralizing, in various percentages of patients during therapy with the drug Remsima®. This could lead to severe complications.

The Assay Genie Antibody to Infliximab® ELISA Kit can be efficiently used for monitoring infliximab anti-drug antibodies (ADA) in biological samples and is for research use only.

Anti-Infliximab (Remsima®) ADA Qualitative ELISA Kit test principle

The Assay Genie Antibody to infliximab biosimilar (Remsima®) ELISA is a sandwich assay for the determination of antibodies against infliximab biosimilar in serum and plasma samples. During the first incubation period, antibodies to infliximab biosimilar in patient serum/plasma samples are captured by the drug infliximab biosimilar (Remsima®) coated on the wall of the microtiter wells. After washing away the unbound components from samples, a peroxidase-labelled specific conjugate is added to each well and then incubated. After a second washing step, the bound enzymatic activity is detected by addition of tetramethylbenzidine (TMB) chromogen substrate. Finally, the reaction is terminated with an acidic stop solution. The intensity of the reaction colour is directly proportional to the concentration of antibodies to infliximab in the sample.

Anti-Infliximab ADA Qualitative ELISA Product Information

Information Description
Application
Free drug
Required Volume (uL)
10
Total Time (min)
140
Sample Type
Serum, Plasma
Number of Assays
96
Detection Limit (ng/mL)
30 (ng/mL)
Spike Recovery (%)
85-115%

Shelf Life (year)

1

Alternative Names

Tumour Necrosis Factor Alpha

Remsima

Anti-Infliximab (Remsima®) ADA Qualitative - Key Information

Infliximab mode of action

Infliximab (Remsima®) is a chimeric monoclonal antibody and used to treat autoimmune disorders. Infliximab reduces the amount of active human tumour necrosis factor alpha (hTNF alpha) in the body by binding to it and preventing it from signalling the receptors for TNF alpha on the surface of various cell types. TNF alpha is one of the key cytokines that triggers and sustains the inflammatory reactions.

Infliximab uses

Remsima, is the world’s first biosimilar mAb (approved in 2013 by EMA). The Committee for Medicinal Products for Human Use (CHMP) decided that, in accordance with EU requirements, Remsima has been shown to have a comparable quality, safety and efficacy profile to Remicade. Remsima is a tumor necrosis factor alpha (TNF-alpha) antagonist used to treat rheumatoid arthritis, ankylosing spondylitis, ulcerative colitis, adult Crohn's disease, plaque psoriasis, and psoriatic arthritis.

Infliximab immunogenicity

One of the major concern, despite of its wide usage, is potential development of anti-infliximab antibodies (ATI) which in turn may interfere with infliximab (Remsima®) efficacy as mainly judged by observing the relapse of signs and symptoms of disease and necessitate dose-escalation or potentially ending up the treatment. In this context, demonstration of anti-infliximab antibodies during treatment with infliximab (Remsima®) has a major concern and monitoring for the presence and/or quantitation of specific antibodies during clinical trials is an important issue for follow up of the treatment regimens.

The Assay Genie® ATI ELISA Kit can be efficiently used for monitoring infliximab-specific antibodies during therapy and is for research use only. With this Assay Genie® ELISA test, anti-infliximab antibodies can be detected and is for research use only.

Anti-Infliximab (Remsima®) ADA Qualitative ELISA Kit Contents

Size Kit Contents

1x12x8

Microtiter Plate

Break apart strips. Microtiter plate with 12 rows each of 8 wells coated with infliximab biosimilar.

1x0.25

Reactive Control
Ready-to-use. Contains infliximab-reactive reagent, human serum, stabilizers and <0.1% NaN3

1 x 0.5 mL

Negative Control
Ready-to-use. Contains human serum, stabilizers and <0.1% NaN3

1 x 12 mL

Assay Buffer
Blue coloured. Ready to use. Contains proteins and <0.1% NaN3

1 x 12 mL

Peroxidase Conjugate
Red coloured. Ready to use. Contains peroxidase (POD) conjugate,
stabilizer and preservatives.

1 x 12 mL

TMB Substrate Solution
Ready to use. Contains TMB

1 x 12 mL

TMB Stop Solution
Ready to use. 1N HCl

1 x 50mL

Wash Buffer, concentrate (20x) Contains Buffer with Tween 20.

2x1

Adhesive Film
For covering of Microtiter Plate during incubation.


Anti-Infliximab (Remsima®) ADA Qualitative ELISA Kit Protocol

Steps Protocol

1

Pipette 100µl of Assay Buffer non-exceptionally into each of the wells to be used.

2

QUALITATIVE ELISA TEST FORMAT
Pipette 10 µL of ready-to use Negative Control, Reactive Control, and Samples into the respective wells of microtiter plate.

Wells
A1: Negative Control
B1: Negative Control
C1: Reactive Control
D1 and on: Sample (Serum/Plasma)

3

Cover the plate with adhesive film. Briefly mix contents by gently shaking the plate. Incubate 60 min at room temperature (18-25°C).

4

Remove adhesive film. Discard incubation solution. Wash plate 3 times each with 300 µL of diluted Wash Buffer. Remove excess solution by tapping the inverted plate on a paper towel.

5

Pipette 100 µL of ready-to use Peroxidase Conjugate into each well.

6

Cover the plate with adhesive film. Incubate 60 min at room temperature (18- 25°C).

7

Remove adhesive film. Discard incubation solution. Wash plate 3 times each with 300 µL of diluted Wash Buffer. Remove excess solution by tapping the inverted plate on a paper towel.

8

Pipette 100 µL of TMB Substrate Solution into each well.

9

Incubate 20 min (without adhesive foil) at room temperature (18-25°C) in the dark

10

Stop the substrate reaction by adding 100 µL of Stop Solution into each well. Briefly mix contents by gently shaking the plate. Colour changes from blue to yellow.

11

Measure optical density with a photometer at 450/650 nm within 30 min after pipetting of the Stop Solution.

Trademarks

REMSIMA is a trademark of CELLTRION, INC.