Flow Cytometry Antibodies
PD-1 (programmed cell death protein 1, also known as CD279, PD1, hSLE1 and SLEB2) is an immune-inhibitory receptor expressed on activated T cells. Assay Genie offers 31 anti-PD-1 antibodies for flow cytometry across 2 species groups, 4 clones and 11 formats, from purified and biotin to FITC, PE, APC, tandem dyes and GenieFluor violet and red dyes.
Rows are colours grouped by excitation laser; columns are clones. Click a SKU to see sizes, live price and the datasheet. Two SKUs in one cell are different pack sizes.
10 antibodies · clones EH12.2H7, J116, J110
| Colour | Laser | EH12.2H7 | J116 | J110 |
|---|---|---|---|---|
| Purified | No dye (unconjugated) | – | AGEL1606LE/AFAGEL1607 | AGEL2093LE/AFAGEL2401 |
| FITC | 488 nm blue | AGEL3070 | – | – |
| PerCP/Cyanine5.5 | 488 nm blue | AGEL3158 | – | – |
| PE | 488 or 561 nm | AGEL2723 | – | – |
| PE/Cyanine7 | 488 or 561 nm | AGEL9607 | – | – |
| APC | 633-640 nm red | AGEL2724 | – | – |
| GenieFluor 700 | 633-640 nm red | AGEL4567 | – | – |
21 antibodies · clone 29F.1A12
| Colour | Laser | 29F.1A12 |
|---|---|---|
| Purified | No dye (unconjugated) | AGEL1624LE/AFAGEL1625 |
| Biotin | Via labelled streptavidin | AGEL1626 |
| FITC | 488 nm blue | AGEL1627AGEL1632 |
| PerCP/Cyanine5.5 | 488 nm blue | AGEL2256AGEL2258 |
| PE | 488 or 561 nm | AGEL1628AGEL1633 |
| PE/Cyanine5.5 | 488 or 561 nm | AGEL1630AGEL1635 |
| PE/Cyanine7 | 488 or 561 nm | AGEL2255AGEL2257 |
| APC | 633-640 nm red | AGEL1629AGEL1634 |
| GenieFluor 647 | 633-640 nm red | AGEL1631AGEL1636 |
| GenieFluor 700 | 633-640 nm red | AGEL4159AGEL4160 |
| GenieFluor Red 780 | 633-640 nm red | AGEL3097AGEL3118 |
Match each colour to a laser your cytometer has, then put bright dyes on weak markers and dimmer or spare channels on abundant ones.
Human: EH12.2H7, J116, J110. Mouse: 29F.1A12. Use the tables above to see which colours each clone comes in.
Yes. Clone 29F.1A12 (anti-Mouse) is available in 11 formats, so you can keep the same clone while moving PD-1 to whichever channel your panel has free.
It depends on how strongly PD-1 is expressed on your cells and which lasers you have. See Choosing a colour for the 9 colours available on each laser.
Yes for Fc receptor-rich mouse cells (spleen, blood, myeloid cells). Pre-incubate with anti-mouse CD16/32 [2.4G2] (AGEL0050) before adding the panel.
Low endotoxin, azide-free purified formats, suited to functional assays as well as flow cytometry. Check each datasheet for details.