GenieColor Mycoplasma Detection Kit (MORV0013) in HCC Cells

GenieColor Mycoplasma Detection Kit (MORV0013) in HCC Cells

Whitepaper banner: GenieColor Mycoplasma Detection Kit (MORV0013) cited in Yan et al. (2026), Cancer Research, on MYC-dependent rRNA catabolism stress in hepatocellular carcinoma cells under glutamine deprivation, with DOI and the Assay Genie GenieColor kit

Summary

The GenieColor Mycoplasma Detection Kit (MORV0013) is a one-hour, single-temperature LAMP test that screens 1 µl of cell-culture supernatant for 40 mycoplasma species; the tube stays pink if negative and turns yellow if positive. A 2026 Cancer Research study by Yan and colleagues, on why hepatocellular carcinoma (HCC) cells differ in their survival under glutamine deprivation, names GenieColor in its text; the citation record links the kit to human cell lines.

Key takeaways

  • Yan et al. (2026) name the GenieColor Mycoplasma Detection Kit (Assay Genie) in a study of MYC-driven survival differences between HCC cells under glutamine deprivation [1].
  • The kit served as a cell-culture quality-control step; the article is subscription-only and its methods detail was not accessible, so test frequency and results are not described here.
  • GenieColor runs 60 min at 65 °C on 1 µl of supernatant and covers 40 species, with a pink-to-yellow visual read-out (product page) [5].
  • Mycoplasma alters proliferation, metabolism and gene expression, the readouts that nutrient-stress studies depend on [3].

Product cited in this study

GenieColor Mycoplasma Detection Kit (MORV0013)
MORV0013

GenieColor Mycoplasma Detection Kit (MORV0013)

Pink to yellow60 min at 65 °C40 species

Named by Yan et al. (2026) in a Cancer Research study of hepatocellular carcinoma cells under glutamine deprivation.

View kit →

At a glance

StudyModel / speciesSample typeProductWhat it measuredKey role in study
Yan et al., 2026, Cancer Research [1]HCC cell lines (human per citation record; names not accessible)Not accessible (abstract only)GenieColor Mycoplasma Detection Kit (MORV0013)Mycoplasma contamination statusCell-culture quality control (methods detail not accessible)

Why mycoplasma testing matters

Mycoplasmas are very small bacteria without a cell wall. Drexler and Uphoff describe contamination of cell cultures as a major problem, and note that mycoplasmas resist most antibiotics used in culture [2]. ATCC puts contamination at 15–35% of continuous cell cultures and at least 1% of primary cultures [3]. The DSMZ cell bank reports that almost 20% of cultures it receives from other laboratories are contaminated [4].

The effects reach the readouts that metabolic studies depend on. ATCC lists inhibition of cell proliferation and metabolism, changes in gene expression profiles, chromosomal aberrations and cell death among the consequences of infection [3]. In a study comparing how cell lines survive nutrient stress, an undetected infection could be mistaken for a biological difference. ATCC advises routine testing so that experimental results can be trusted, and DSMZ keeps incoming cultures isolated until their mycoplasma status is known [3, 4].

Workflow diagram: cell culture supernatant (1 µl) is added to GenieColor LAMP mix, incubated at 65 °C for 60 minutes, and read by eye as pink (negative) or yellow (positive).
Figure 1. GenieColor workflow per the product page: 1 µl of supernatant plus 19 µl of LAMP mix, 60 minutes at 65 °C, read by eye (pink negative, yellow positive). Reference colours, not study results.

How GenieColor works

GenieColor uses loop-mediated isothermal amplification (LAMP). According to the product page, the pre-mixed reagent contains Bst polymerase, mycoplasma-specific inner and outer primers and an optimised buffer. If mycoplasma DNA is present, amplification turns the reaction from pink to yellow [5]. A calibrated water bath (with mineral oil) or a PCR instrument is the only equipment needed.

Product-page specifications [5]:

  • Run: 60 min at 65 °C, single step; 1 µl sample + 19 µl LAMP mix = 20 µl
  • Coverage: 40 species, including M. hyorhinis, M. fermentans, M. arginini, M. orale, M. hominis, M. salivarium, M. pirum and A. laidlawii
  • Limit of detection: 100 copies/µl (positive-control plasmid)
  • Controls: positive (M. hyorhinis plasmid, 10 ng/µl) and negative, included
  • Pack sizes: 25 or 50 tests, plus a 10-test sample pack; store at −30 to −15 °C

How the kit was used in published research

Yan et al. (2026): MYC and survival heterogeneity of HCC cells under glutamine deprivation

Research question. Yan and colleagues asked why some HCC cells die when glutamine is withdrawn while others survive [1].

What the abstract reports. MYC expression governed the response. In sensitive cells, MYC recruited ULK1 to phosphorylate ribosomal protein L12 (RPL12). This triggered ribophagy, breakdown of rRNA and a surge in reactive oxygen species (ROS) that led to cell death. Adenosine released by rRNA breakdown further raised MYC expression, creating a feed-forward loop. MYC-high tumours responded to the glutaminase inhibitor CB-839 alone, whereas MYC-low tumours needed CB-839 combined with the pro-oxidant elesclomol [1].

Where GenieColor fits. The link to this paper rests on a Google Scholar text snippet that names the GenieColor Mycoplasma Detection Kit (Assay Genie); the kit is not named in the abstract, and the abstract does not name the cell lines or their species. The article is subscription-only and only the abstract is publicly accessible, so methods detail was not accessible. Cell-line names, testing frequency, sample handling and results are therefore not described here.

How the readout supports the conclusions. Mycoplasma testing is a quality-control step, not an endpoint. Its role in a study like this is to rule out infection, which can alter proliferation and metabolism [3], as an explanation for differences in survival, ROS and rRNA breakdown between HCC lines. The paper's reported test outcome was not accessible.

Schematic: HCC cell lines are tested with GenieColor; negative lines proceed to glutamine-deprivation experiments, positive lines are discarded.
Figure 2. Generic position of mycoplasma QC: lines are screened with GenieColor and only negative lines go on to glutamine-deprivation assays. A schematic, not the authors' reported workflow.

Practical protocol considerations

Generic best practice, not from the cited paper:

  • Sample at the right time. The product page advises leaving cells undisturbed for at least 72 h and testing adherent lines at about 90% confluence, when mycoplasma levels in the supernatant are highest. Centrifuge suspension cultures at 500 × g for 5 min and test the supernatant [5].
  • Run both controls every time. Include the kit's positive control and a nuclease-free water negative in each batch [5].
  • Keep tubes closed after the run. Opening tubes after amplification can release aerosols that cause false positives [5].
  • Quarantine new lines. ATCC notes that quarantining new lines reduces the risk of cross-contamination, and DSMZ isolates incoming cultures until their mycoplasma status is known [3, 4].
  • Do not rely on antibiotics. Standard antibiotics do not protect cultures against mycoplasma [3].

Testing your cell lines for mycoplasma?

The GenieColor Mycoplasma Detection Kit cited in this study is available from Assay Genie, with expert technical support.

View the GenieColor kit →

Frequently asked questions

How long does the GenieColor mycoplasma test take?

One incubation of 60 minutes at 65 °C. The result is read by eye straight from the tube: pink is negative and yellow is positive. A calibrated water bath or a PCR instrument used as a heater is enough, and no gel electrophoresis, plate reader or qPCR instrument is needed.

Which mycoplasma species does GenieColor detect?

The product page lists 40 species. These include the eight contaminants behind most cell-line infections: M. hyorhinis, M. fermentans, M. arginini, M. orale, M. hominis, M. salivarium, M. pirum and Acholeplasma laidlawii. The stated limit of detection is 100 copies/µl, measured with the kit's positive-control plasmid.

What does a colour between pink and yellow mean?

The kit treats an intermediate colour as a weak positive and advises repeating the test. If the repeat is positive or weak positive, the culture is considered positive; if the repeat is negative, it is considered negative. Always compare samples with the positive and negative controls run in the same batch.

References

  1. Yan Z, Wu D, Wu J, Shi C, Feng M, Li Y, Wang G, Liu X, et al. MYC-Dependent rRNA Catabolism Stress Dictates Survival Heterogeneity of Hepatocellular Carcinoma Cells Under Glutamine Deprivation. Cancer Research. 2026 (online 29 Sep 2026). doi:10.1158/0008-5472.CAN-26-0575.
  2. Drexler HG, Uphoff CC. Mycoplasma contamination of cell cultures: Incidence, sources, effects, detection, elimination, prevention. Cytotechnology. 2002;39:75–90.
  3. ATCC. Mycoplasma contamination.
  4. DSMZ. Mycoplasma detection and eradication.
  5. Assay Genie. GenieColor Mycoplasma Detection Kit (MORV0013), product page (read 24 Nov 2026).
AG
Assay Genie Scientific Team

Application notes written by Assay Genie's PhD scientists from peer-reviewed publications that cite our products. Figures created in BioRender.

24th Nov 2026 Assay Genie Scientific Team

Recent Posts